Guanghu Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Guanghu Xu has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Deping Ke
Wuhan University
2 shared publications - Huanhuan Yang
Dispatching Control Center, China Southern Power Grid, Guangzhou 501699, China
2 shared publications - Siyang Liao
Wuhan University
2 shared publications - Huanhuan Yang
The Power Dispatching and Control Center, China Southern Power Grid, Guangzhou 510623, China
1 shared publication - Jian Qiu
Power Dispatching Control Center, China Southern Power Grid, Guangzhou 510663, China
1 shared publication - Jian Xu
Wuhan University
1 shared publication
Latest Publications
- Open Access
- 24 April 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (9) , 3846
Deep Reinforcement Learning-Based Adaptive Transient Voltage Control of Power Systems by Distributed Collaborative Modulation of Voltage-Source Converters with Operational Constraints of Current Saturation
This paper presents a novel deep reinforcement learning (DRL)-based method for the adaptive control of transient voltage in power systems. First, we propose a neural network-based nonlinear controller (TVCON) designed to modulate each voltage-source converter (VSC), such as photovoltaic systems or energy storage systems, that actively contributes to transient voltage control. Subsequently, all distributed TVCONs can collaborate to rapidly restore system voltage during fault transients by centrally optimizing their parameters (weight coefficients). Specifically, the optimization is conducted periodically using incremental DRL to efficiently update the TVCONs’ parameters in accordance with the practical operating conditions of the system and VSCs. Consequently, the provision of transient reactive current by VSCs, which have operational constraints related to current saturation, can be feasibly and adaptively controlled by the TVCONs while considering their steady-state active current outputs. Additionally, the inappropriate sacrifice of VSCs’ active current and the resulting adverse impacts can be effectively mitigated. Finally, simulations conducted on a modified IEEE 14-Bus system validate the proposed method.
- 24 April 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (9) , 3846
Open AccessDeep Reinforcement Learning-Based Adaptive Transient Voltage Control of Power Systems by Distributed Collaborative Modulation of Voltage-Source Converters with Operational Constraints of Current Saturation
This paper presents a novel deep reinforcement learning (DRL)-based method for the adaptive control of transient voltage in power systems. First, we propose a neural network-based nonlinear controller (TVCON) designed to modulate each voltage-source converter (VSC), such as photovoltaic systems or energy storage systems, that actively contributes to transient voltage control. Subsequently, all distributed TVCONs can collaborate to rapidly restore system voltage during fault transients by centrally optimizing their parameters (weight coefficients). Specifically, the optimization is conducted periodically using incremental DRL to efficiently update the TVCONs’ parameters in accordance with the practical operating conditions of the system and VSCs. Consequently, the provision of transient reactive current by VSCs, which have operational constraints related to current saturation, can be feasibly and adaptively controlled by the TVCONs while considering their steady-state active current outputs. Additionally, the inappropriate sacrifice of VSCs’ active current and the resulting adverse impacts can be effectively mitigated. Finally, simulations conducted on a modified IEEE 14-Bus system validate the proposed method.
- Open Access
- 23 February 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (5) , 1892
Robust Emergency Frequency Control with Wind Turbines via Decoupling Security Constraints and Modeling Uncertainties
In this paper, controllable wind turbines are employed for emergency frequency control to reduce cost. However, controllable wind turbines introduce significant modeling uncertainties in the form of uncertain environmental factors and model aggregation into the system. To pre-generate feasible emergency control strategies at the lowest cost, a robust optimization model is constructed for a potentially serious fault in power systems, which is a mixed-integer nonlinear robust programming issue with non-analytical calculation (for post-event system frequency). Therefore, this study proposes to first quantify the impact of modeling uncertainties on wind turbine regulation and find the most unfavorable uncertain scenarios for emergency frequency control. Then, based on the above-filtered scenarios, the original problem is transformed into mixed-integer nonlinear programming. A novel simplified algorithm is proposed to solve the above problem efficiently. Finally, a case study is conducted on a real regional power system. It is proved effective in reducing costs by regulating wind turbines for emergency control, and the proposed method is effective in dealing with the impact of modeling uncertainties. Also, high solving efficiency (12 s in case study) meets the demand for efficient online pre-decision-making for emergency control. The research is meaningful in the promotion of secure access to power systems for sustainable power.
- 23 February 2025
- Published by MDPI AG in Sustainability
- Vol. 17 (5) , 1892
Open AccessRobust Emergency Frequency Control with Wind Turbines via Decoupling Security Constraints and Modeling Uncertainties
In this paper, controllable wind turbines are employed for emergency frequency control to reduce cost. However, controllable wind turbines introduce significant modeling uncertainties in the form of uncertain environmental factors and model aggregation into the system. To pre-generate feasible emergency control strategies at the lowest cost, a robust optimization model is constructed for a potentially serious fault in power systems, which is a mixed-integer nonlinear robust programming issue with non-analytical calculation (for post-event system frequency). Therefore, this study proposes to first quantify the impact of modeling uncertainties on wind turbine regulation and find the most unfavorable uncertain scenarios for emergency frequency control. Then, based on the above-filtered scenarios, the original problem is transformed into mixed-integer nonlinear programming. A novel simplified algorithm is proposed to solve the above problem efficiently. Finally, a case study is conducted on a real regional power system. It is proved effective in reducing costs by regulating wind turbines for emergency control, and the proposed method is effective in dealing with the impact of modeling uncertainties. Also, high solving efficiency (12 s in case study) meets the demand for efficient online pre-decision-making for emergency control. The research is meaningful in the promotion of secure access to power systems for sustainable power.
- Open Access
Coordinated Control of Transient Voltage Support in Doubly Fed Induction Generators
The large-scale integration of wind power significantly alters the voltage dynamic characteristics of power systems. Wind turbines have a weak ability to withstand grid disturbances and have difficulty in providing effective reactive power support during transient periods. The sensitivity of wind turbines to the grid voltage significantly increases the probability of large-scale, cascading off-grid events. This paper proposes a coordinated control strategy to enhance the transient reactive power support capability of doubly fed wind farms. The additional stator current demagnetization control reduces the risk of a crowbar protection action after a fault and ensures that the unit power is controllable. Based on the voltage–reactive power coupling relationship, each unit can produce reactive power according to the voltage–reactive power sensitivity matrix during the transient period. After the reactive power output of the unit reaches the limit, transient active and reactive combined control is further adopted to reduce the active power output of the unit to a certain extent and improve the reactive power support capability. Finally, two cases are built in the PSCAD to verify the effectiveness of the proposed control strategy. The results show that the proposed control strategy can enable the wind farm to output more reactive power to the grid during the transient period, effectively supporting the system voltage during the transient process and avoiding further deterioration of the fault.
Open AccessCoordinated Control of Transient Voltage Support in Doubly Fed Induction Generators
The large-scale integration of wind power significantly alters the voltage dynamic characteristics of power systems. Wind turbines have a weak ability to withstand grid disturbances and have difficulty in providing effective reactive power support during transient periods. The sensitivity of wind turbines to the grid voltage significantly increases the probability of large-scale, cascading off-grid events. This paper proposes a coordinated control strategy to enhance the transient reactive power support capability of doubly fed wind farms. The additional stator current demagnetization control reduces the risk of a crowbar protection action after a fault and ensures that the unit power is controllable. Based on the voltage–reactive power coupling relationship, each unit can produce reactive power according to the voltage–reactive power sensitivity matrix during the transient period. After the reactive power output of the unit reaches the limit, transient active and reactive combined control is further adopted to reduce the active power output of the unit to a certain extent and improve the reactive power support capability. Finally, two cases are built in the PSCAD to verify the effectiveness of the proposed control strategy. The results show that the proposed control strategy can enable the wind farm to output more reactive power to the grid during the transient period, effectively supporting the system voltage during the transient process and avoiding further deterioration of the fault.