Neha Ahlawat
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Neha Ahlawat has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Awanish Pandey
Optics and Photonics Centre, Indian Institute of Technology Delhi, New Delhi, India
1 shared publication - Krishnan Kundan
Indian Institute of Technology Delhi
1 shared publication Saurabh Mani Tripathi
Indian Institute of Technology Delhi
1 shared publication- Saurabh Mani Tripathi
Indian Institute of Technology Kanpur
1 shared publication - Saurabh Mani Tripathi
Department of Physics, Indian Institute of Technology Kanpur, Kanpur, India
1 shared publication Shalini Kumari
Indian Institute of Technology Delhi
1 shared publication
Latest Publications
- 21 May 2026
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 25 (5)
Exceptional-point dynamics in photonic time crystals for enhanced optical sensing
- 21 May 2026
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 25 (5)
Exceptional-point dynamics in photonic time crystals for enhanced optical sensing
- 27 April 2026
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 43 (8) , B110
Mode-engineered SMS fiber sensor with neural-network-based decoupling of strain and temperature
We report a compact, mode-engineered single-mode–multimode–single-mode (SMS) fiber sensor that uses a regression neural network operating on physics-motivated spectral features to simultaneously estimate axial elongation and temperature. A controlled transverse core offset at the single-mode fiber (SMF)–multimode fiber (MMF) splice excites higher-order modes in a graded-index MMF, producing broadband multimode interference with strongly non-affine spectral evolution under perturbation. To decouple the two parameters, the measured spectrum is standardized, compressed using principal component analysis (PCA), augmented with a small set of physics-motivated descriptors, and processed by a regression artificial neural network (ANN). The resulting ANN–PCA + Phys model, trained on a 13-dimensional feature space, achieves five-fold cross-validated root-mean-square errors (RMSE) of 13.75 µm and 14.56°C for elongation and temperature, with aggregated coefficients of determination R 2 ≈0.89 and 0.80, respectively. For the 4.2 cm gauge length, the elongation RMSE corresponds to a strain resolution of ∼330µ ϵ . Although these absolute resolutions are modest compared with state-of-the-art fiber Bragg grating and long-period grating sensors, the proposed co-designed approach—combining modal engineering, feature-guided dimensionality reduction, and compact machine-learning models in a strict small-data regime—illustrates a general route toward multi-parameter fiber sensors with complex spectra that are otherwise difficult to invert analytically.
- 27 April 2026
- Published by Optica Publishing Group in Journal of the Optical Society of America B
- Vol. 43 (8) , B110
Mode-engineered SMS fiber sensor with neural-network-based decoupling of strain and temperature
We report a compact, mode-engineered single-mode–multimode–single-mode (SMS) fiber sensor that uses a regression neural network operating on physics-motivated spectral features to simultaneously estimate axial elongation and temperature. A controlled transverse core offset at the single-mode fiber (SMF)–multimode fiber (MMF) splice excites higher-order modes in a graded-index MMF, producing broadband multimode interference with strongly non-affine spectral evolution under perturbation. To decouple the two parameters, the measured spectrum is standardized, compressed using principal component analysis (PCA), augmented with a small set of physics-motivated descriptors, and processed by a regression artificial neural network (ANN). The resulting ANN–PCA + Phys model, trained on a 13-dimensional feature space, achieves five-fold cross-validated root-mean-square errors (RMSE) of 13.75 µm and 14.56°C for elongation and temperature, with aggregated coefficients of determination R 2 ≈0.89 and 0.80, respectively. For the 4.2 cm gauge length, the elongation RMSE corresponds to a strain resolution of ∼330µ ϵ . Although these absolute resolutions are modest compared with state-of-the-art fiber Bragg grating and long-period grating sensors, the proposed co-designed approach—combining modal engineering, feature-guided dimensionality reduction, and compact machine-learning models in a strict small-data regime—illustrates a general route toward multi-parameter fiber sensors with complex spectra that are otherwise difficult to invert analytically.
- Open Access
- 18 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 16 (5) , 1-9
Plasmonic Mode Interference Effect Based Sensors
We propose and theoretically analyze a novel sensor based on plasmonic mode interference in a one-dimensional degenerate n-doped silicon core waveguide. The waveguide supports both, the symmetric- as well as anti-symmetric surface plasmon polaritons (SPPs), with a large propagation constant difference between them, drastically miniaturizing the probe size to $\sim$ 100 $\mu$ m. Our study reveals that the symmetric plasmonic mode has significant field localization in the sensing region as compared to the anti-symmetric plasmonic mode which has a large field localization in the substrate region. This makes the symmetric SPP considerably more suitable for bio/chemical sensing applications. The core mode projection technique with an optimized transverse offset between the lead-in waveguide and plasmonic waveguide has been used to couple appreciable power into the two SPP modes enhancing the extinction ratio of the transmission spectra. The estimated sensitivity of the sensor is $\sim$ 3400 nm/RIU over biologically relevant refractive indices. Our study demonstrates the effectiveness of plasmonic mode interference in designing highly sensitive bio/chemical sensors with miniaturized probe length through careful design considerations. We also discuss the effect of temperature cross-sensitivity on the performance of the sensor and have presented a sensitivity matrix-based approach for the simultaneous detection of two perturbations using a single sensor probe. We have shown that using this sensitivity-matrix approach, the error associated with the estimated variations in the perturbations is of the order of 10 $^{-4}$ to 10 $^{-3}$ , making it a powerful tool to estimate simultaneously varying perturbation parameters by tracking multiple resonances.
- 18 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 16 (5) , 1-9
Open AccessPlasmonic Mode Interference Effect Based Sensors
We propose and theoretically analyze a novel sensor based on plasmonic mode interference in a one-dimensional degenerate n-doped silicon core waveguide. The waveguide supports both, the symmetric- as well as anti-symmetric surface plasmon polaritons (SPPs), with a large propagation constant difference between them, drastically miniaturizing the probe size to $\sim$ 100 $\mu$ m. Our study reveals that the symmetric plasmonic mode has significant field localization in the sensing region as compared to the anti-symmetric plasmonic mode which has a large field localization in the substrate region. This makes the symmetric SPP considerably more suitable for bio/chemical sensing applications. The core mode projection technique with an optimized transverse offset between the lead-in waveguide and plasmonic waveguide has been used to couple appreciable power into the two SPP modes enhancing the extinction ratio of the transmission spectra. The estimated sensitivity of the sensor is $\sim$ 3400 nm/RIU over biologically relevant refractive indices. Our study demonstrates the effectiveness of plasmonic mode interference in designing highly sensitive bio/chemical sensors with miniaturized probe length through careful design considerations. We also discuss the effect of temperature cross-sensitivity on the performance of the sensor and have presented a sensitivity matrix-based approach for the simultaneous detection of two perturbations using a single sensor probe. We have shown that using this sensitivity-matrix approach, the error associated with the estimated variations in the perturbations is of the order of 10 $^{-4}$ to 10 $^{-3}$ , making it a powerful tool to estimate simultaneously varying perturbation parameters by tracking multiple resonances.