Zhenhua Nie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zhenhua Nie has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Bo Wang
1 shared publicationHao Liu
1 shared publicationHongye Su
1 shared publication- Hongye Su
Zhejiang University
1 shared publication - Jianshan Lu
College of Mechanical Engineering, Zhejiang University of Technology, Hangzhou 310023, China
1 shared publication Lei Wang
1 shared publication
Latest Publications
- Open Access
- 11 February 2026
- Published by Elsevier in SSRN Electronic Journal
Adaptive Remaining Useful Life Prediction of Proton Exchange Membrane Fuel Cells Based on Mechanism-Guided Feature Selection and Inverted Transformer Network
Predicting the remaining useful life (RUL) of proton exchange membrane fuel cells (PEMFCs) is central to their prognostics and health management. Accurate and reliable RUL prediction facilitates improvement in the durability of PEMFCs. To fully leverage the advantages of both mechanismbased models and data-driven methods while mitigating the impact of measurement noise on RUL prediction, this paper proposes a hybrid adaptive RUL prediction method based on mechanismguided feature selection and inverted Transformer (iTransformer) network. Firstly, by analyzingthe polarization processes within the stack, the polarization model is reconstructed and refined. Selecting feature data from the improved polarization model enhances the interpretability of feature selection. Subsequently, by incorporating the variable embedding strategy and structurally modified Transformer, the capability to capture multivariate correlations is enhanced, enabling multi-step prediction of voltage degradation. Finally, the sliding-window pointwise adaptive algorithm (SWPAA) is designed to perform adaptive filtering and extend the signal boundary based on the volatility ofpredicted decay voltage, which reduces the impact of severe fluctuations in the measured voltage on RUL prediction and achieves robust interval prediction of RUL. Compared with the bidirectional long short-term memory, echo state network, unscented Kalman filter, and Transformer prediction models, iTransformer demonstrated the highest accuracy in both time-series voltage prediction and RUL prediction. Furthermore, the robust RUL interval obtained via SWPAA further enhances theprecision and reliability of RUL prediction.
- 11 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessAdaptive Remaining Useful Life Prediction of Proton Exchange Membrane Fuel Cells Based on Mechanism-Guided Feature Selection and Inverted Transformer Network
Predicting the remaining useful life (RUL) of proton exchange membrane fuel cells (PEMFCs) is central to their prognostics and health management. Accurate and reliable RUL prediction facilitates improvement in the durability of PEMFCs. To fully leverage the advantages of both mechanismbased models and data-driven methods while mitigating the impact of measurement noise on RUL prediction, this paper proposes a hybrid adaptive RUL prediction method based on mechanismguided feature selection and inverted Transformer (iTransformer) network. Firstly, by analyzingthe polarization processes within the stack, the polarization model is reconstructed and refined. Selecting feature data from the improved polarization model enhances the interpretability of feature selection. Subsequently, by incorporating the variable embedding strategy and structurally modified Transformer, the capability to capture multivariate correlations is enhanced, enabling multi-step prediction of voltage degradation. Finally, the sliding-window pointwise adaptive algorithm (SWPAA) is designed to perform adaptive filtering and extend the signal boundary based on the volatility ofpredicted decay voltage, which reduces the impact of severe fluctuations in the measured voltage on RUL prediction and achieves robust interval prediction of RUL. Compared with the bidirectional long short-term memory, echo state network, unscented Kalman filter, and Transformer prediction models, iTransformer demonstrated the highest accuracy in both time-series voltage prediction and RUL prediction. Furthermore, the robust RUL interval obtained via SWPAA further enhances theprecision and reliability of RUL prediction.
- 23 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (4) , 4053-4062
Fault Diagnosis for Proton Exchange Membrane Fuel Cell Systems via Improved Equivalent Circuit Model and Multiple Support Vector Machines
Fault diagnosis is of paramount importance in ensuring the reliability and stability of proton exchange membrane fuel cell systems. In this article, an innovative fault diagnosis method based on an improved equivalent circuit model (ECM) and multiple support vector machines (multi-SVMs) arranged in series is proposed. This method can enhance the interpretability of the ECM and feature data while achieving more efficient and accurate fault diagnosis. Initiating the process, the anode/cathode activation impedance, oxygen mass transfer impedance, and ohmic impedance are considered to design an improved ECM with a streamlined set of parameters for identification. The advantage of the improved ECM in terms of accuracy is demonstrated by comparison with two recently proposed ECMs. Then, a novel parameter identification method, integrating simulated annealing and complex nonlinear least square approach, is introduced to identify ECM parameters more efficiently and accurately. Finally, the multi-SVM classifier is built by concatenating multiple binary SVM models, then trained and validated using measured operating parameters from a 60 kW physical test bench and identified ECM parameters as feature data. Through a comparative evaluation with other classical classifiers, the advantages of multi-SVM in terms of training efficiency and classification accuracy can be demonstrated with training time of 0.3 s and test accuracy of 96.15%.
- 23 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (4) , 4053-4062
Fault Diagnosis for Proton Exchange Membrane Fuel Cell Systems via Improved Equivalent Circuit Model and Multiple Support Vector Machines
Fault diagnosis is of paramount importance in ensuring the reliability and stability of proton exchange membrane fuel cell systems. In this article, an innovative fault diagnosis method based on an improved equivalent circuit model (ECM) and multiple support vector machines (multi-SVMs) arranged in series is proposed. This method can enhance the interpretability of the ECM and feature data while achieving more efficient and accurate fault diagnosis. Initiating the process, the anode/cathode activation impedance, oxygen mass transfer impedance, and ohmic impedance are considered to design an improved ECM with a streamlined set of parameters for identification. The advantage of the improved ECM in terms of accuracy is demonstrated by comparison with two recently proposed ECMs. Then, a novel parameter identification method, integrating simulated annealing and complex nonlinear least square approach, is introduced to identify ECM parameters more efficiently and accurately. Finally, the multi-SVM classifier is built by concatenating multiple binary SVM models, then trained and validated using measured operating parameters from a 60 kW physical test bench and identified ECM parameters as feature data. Through a comparative evaluation with other classical classifiers, the advantages of multi-SVM in terms of training efficiency and classification accuracy can be demonstrated with training time of 0.3 s and test accuracy of 96.15%.