Cheng Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Cheng Xu has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Hui Pang
Institute of Optics and Electronics, Chinese Academy of Sciences, Chengdu 610209, China
2 shared publications - Jun Lan
National Key Laboratory of Optical Field Manipulation Science and Technology, Chinese Academy of Sciences, Chengdu, China
2 shared publications - Song Hu
National Key Laboratory of Optical Field Manipulation Science and Technology, Chinese Academy of Sciences, Chengdu 610209, China
2 shared publications - Chao Yang
Institute of Optics and Electronics, Chinese Academy of Science, Chengdu, China
1 shared publication Lixin Zhao
National Key Laboratory of Optical Field Manipulation Science and Technology, Chinese Academy of Sciences, Chengdu, China
1 shared publication- Wei Yan
State Key Laboratory of Optical Field Manipulation Science and Technology, Institute of Optics and Electronics, Chinese Academy of Sciences, Chengdu 610209, China
1 shared publication
Latest Publications
- Open Access
- 23 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 16 (6) , 1-8
Efficient Phase Retrieval via Improved Binary Amplitude Modulation Masks
Conventional iterative phase retrieval suffers from an inherent phase ambiguity due to limited measurement intensity. Multimodal amplitude modulation introduces physical constraints to tackle the underdetermination challenge. However, the time overhead caused by mask switching slows down the imaging speed. To increase imaging speed, we report an accelerated coded phase retrieval method by optimizing modulation masks. Compared to existing methods that require at least four patterns as inputs, the proposed method requires only three mask modulations to robustly reconstruct complex objects. The transparent pixels of the two masks partially overlap, constituting a strong constraint on the objective function. An additional random mask increases the difference between diffraction intensity patterns and ensures that the algorithm converges. The proposed method of efficient modulation using pure amplitude elements may open the door to short-wavelength high-speed complex amplitude imaging. Numerical simulations and proof-of-principle experiments have verified the feasibility of this method.
- 23 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 16 (6) , 1-8
Open AccessEfficient Phase Retrieval via Improved Binary Amplitude Modulation Masks
Conventional iterative phase retrieval suffers from an inherent phase ambiguity due to limited measurement intensity. Multimodal amplitude modulation introduces physical constraints to tackle the underdetermination challenge. However, the time overhead caused by mask switching slows down the imaging speed. To increase imaging speed, we report an accelerated coded phase retrieval method by optimizing modulation masks. Compared to existing methods that require at least four patterns as inputs, the proposed method requires only three mask modulations to robustly reconstruct complex objects. The transparent pixels of the two masks partially overlap, constituting a strong constraint on the objective function. An additional random mask increases the difference between diffraction intensity patterns and ensures that the algorithm converges. The proposed method of efficient modulation using pure amplitude elements may open the door to short-wavelength high-speed complex amplitude imaging. Numerical simulations and proof-of-principle experiments have verified the feasibility of this method.
- Open Access
- 8 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 16 (2) , 1-5
Resolution-Enhanced Ptychographic Modulation Imaging via Divergent Illumination
By inserting a modulator in the imaging system and scanning in different positions, ptychographic modulation imaging can achieve higher quality reconstruction for smooth or weakly scattered objects compared to conventional ptychography imaging. However, its imaging resolution is still limited by the pixel size of the detector. In this paper, divergent illumination is introduced to enhance imaging resolution. Compared with the original planar illumination scheme, our proposed method can achieve two-fold resolution improvement with only the use of thirty diffraction patterns for ten iterations. The quantitative phase imaging capability of the proposed method is also demonstrated by testing the binary phase sample. In the reconstruction, the divergent illumination geometry is converted to planar illumination model. The equivalent sampling intervals and diffraction distances of the modulator, object, and detector planes are analyzed in detail. In addition, a new high-accuracy distance calibration method for point light sources is proposed and verified in experiments.
- 8 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 16 (2) , 1-5
Open AccessResolution-Enhanced Ptychographic Modulation Imaging via Divergent Illumination
By inserting a modulator in the imaging system and scanning in different positions, ptychographic modulation imaging can achieve higher quality reconstruction for smooth or weakly scattered objects compared to conventional ptychography imaging. However, its imaging resolution is still limited by the pixel size of the detector. In this paper, divergent illumination is introduced to enhance imaging resolution. Compared with the original planar illumination scheme, our proposed method can achieve two-fold resolution improvement with only the use of thirty diffraction patterns for ten iterations. The quantitative phase imaging capability of the proposed method is also demonstrated by testing the binary phase sample. In the reconstruction, the divergent illumination geometry is converted to planar illumination model. The equivalent sampling intervals and diffraction distances of the modulator, object, and detector planes are analyzed in detail. In addition, a new high-accuracy distance calibration method for point light sources is proposed and verified in experiments.