Chihyeong Won
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chihyeong Won has a total of 66 co-authors. Here are the top co-authors by number of shared publications:
- Taeyoon Lee
School of Electrical and Electronic Engineering, Yonsei University, Seoul 03722, Republic of Korea
3 shared publications - Wei Gao
Andrew and Peggy Cherng Department of Medical Engineering, Division of Engineering and Applied Science, California Institute of Technology, Pasadena, CA, USA
3 shared publications - Gwangmook Kim
Andrew and Peggy Cherng Department of Medical Engineering, Division of Engineering and Applied Science, California Institute of Technology, Pasadena, USA
2 shared publications - José A. Lasalde-Ramírez
Division of Engineering and Applied Science, California Institute of Technology, Pasadena, USA
2 shared publications - Tzung K. Hsiai
Department of Bioengineering, UCLA, Los Angeles, CA, USA
2 shared publications Brian Arianpour
Department of Bioengineering, Henry Samueli School of Engineering and Applied Sciences, University of California Los Angeles, Los Angeles, USA
1 shared publication
Latest Publications
- 29 July 2026
- Published by Springer Nature in Nature Sensors
- Vol. 1 (9) , 811-823
Non-invasive continuous lipid profiling via cofactor-refreshing cascading enzymatic reactions and causal machine learning
- 29 July 2026
- Published by Springer Nature in Nature Sensors
- Vol. 1 (9) , 811-823
Non-invasive continuous lipid profiling via cofactor-refreshing cascading enzymatic reactions and causal machine learning
- Open Access
- 29 May 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (22) , eaee2754
Structurally engineered ultrasoft PEDOT:PSS fiber microelectrodes with enhanced electrochemical performance for neural interfaces
Stable and reliable neural interfacing is essential for the diagnosis and treatment of chronic neurological disorders. Flexible neural probes are particularly important for this purpose, as they minimize tissue damage and inflammatory responses while maintaining stable electrode-tissue coupling; however, achieving both high electrical performance and tissue-like mechanics remains challenging. Here, we present a poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS) fiber microelectrode (PFME), an all-organic neural probe capable of recording single-neuron activities with potential for long-term interfacing. The PFME is entirely composed of organic components and fabricated without thermal processing. In addition, the posttreatment process enables to selectively remove PSS binder networks while promoting PEDOT chain alignment to optimize mechanical compliance and electrochemical performance. In vivo, the PFME enables stable single-unit recordings from the mouse hippocampus. Histological analysis after 1 week of implantation reveals minimal glial activation comparable to that elicited by a conventional probe. This structurally engineered PFME establishes a pathway to achieve minimally invasive neural interfacing platforms for chronic applications.
- 29 May 2026
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 12 (22) , eaee2754
Open AccessStructurally engineered ultrasoft PEDOT:PSS fiber microelectrodes with enhanced electrochemical performance for neural interfaces
Stable and reliable neural interfacing is essential for the diagnosis and treatment of chronic neurological disorders. Flexible neural probes are particularly important for this purpose, as they minimize tissue damage and inflammatory responses while maintaining stable electrode-tissue coupling; however, achieving both high electrical performance and tissue-like mechanics remains challenging. Here, we present a poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS) fiber microelectrode (PFME), an all-organic neural probe capable of recording single-neuron activities with potential for long-term interfacing. The PFME is entirely composed of organic components and fabricated without thermal processing. In addition, the posttreatment process enables to selectively remove PSS binder networks while promoting PEDOT chain alignment to optimize mechanical compliance and electrochemical performance. In vivo, the PFME enables stable single-unit recordings from the mouse hippocampus. Histological analysis after 1 week of implantation reveals minimal glial activation comparable to that elicited by a conventional probe. This structurally engineered PFME establishes a pathway to achieve minimally invasive neural interfacing platforms for chronic applications.
- Top Cited PapersOpen Access
- 15 August 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (33) , eadw9024
A bioinspired microfluidic wearable sensor for multiday sweat sampling, transport, and metabolic analysis
Wearable sweat sensors enable noninvasive real-time biochemical monitoring, holding immense potential for personalized health care applications. However, achieving prolonged and reliable sweat sampling, along with stable biochemical analysis, remains challenging due to inconsistent secretion, rapid evaporation, and the reliance on external stimulation. Here, we present BMS 3 , a bioinspired microfluidic wearable sweat sensor system designed for multiday continuous metabolic monitoring. BMS 3 integrates hierarchically graded microchannels and superhydrophobic-superhydrophilic Janus membranes, inspired by pitcher plant trichomes and lotus leaves to enable efficient low volume sweat collection, transport, and renewal. A miniaturized carbachol gel–based iontophoresis module autonomously induces localized sweat secretion. Furthermore, the microfluidic design sustains sweat sampling for over 2 days from a single iontophoresis session, eliminating the need for physical exertion. In vitro and in vivo studies in healthy participants and patients with gout demonstrate BMS 3 ’s capability for continuous metabolic monitoring. By simultaneously tracking uric acid, xanthine, and alcohol levels, it effectively differentiates normal and pathological states while delivering timely therapeutic feedback.
- 15 August 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (33) , eadw9024
Top Cited PapersOpen AccessA bioinspired microfluidic wearable sensor for multiday sweat sampling, transport, and metabolic analysis
Wearable sweat sensors enable noninvasive real-time biochemical monitoring, holding immense potential for personalized health care applications. However, achieving prolonged and reliable sweat sampling, along with stable biochemical analysis, remains challenging due to inconsistent secretion, rapid evaporation, and the reliance on external stimulation. Here, we present BMS 3 , a bioinspired microfluidic wearable sweat sensor system designed for multiday continuous metabolic monitoring. BMS 3 integrates hierarchically graded microchannels and superhydrophobic-superhydrophilic Janus membranes, inspired by pitcher plant trichomes and lotus leaves to enable efficient low volume sweat collection, transport, and renewal. A miniaturized carbachol gel–based iontophoresis module autonomously induces localized sweat secretion. Furthermore, the microfluidic design sustains sweat sampling for over 2 days from a single iontophoresis session, eliminating the need for physical exertion. In vitro and in vivo studies in healthy participants and patients with gout demonstrate BMS 3 ’s capability for continuous metabolic monitoring. By simultaneously tracking uric acid, xanthine, and alcohol levels, it effectively differentiates normal and pathological states while delivering timely therapeutic feedback.
- Open Access
- 24 September 2024
- Published by MDPI AG in Biomedicines
- Vol. 12 (10) , 2169
Increased Susceptibility to Mechanical Stretch Drives the Persistence of Keloid Fibroblasts: An Investigation Using a Stretchable PDMS Platform
Background: Keloids are a common fibrotic disease of the skin, with the pathological hallmark of excessive extracellular matrix synthesis due to abnormal fibroblast activity. Since keloids clinically arise in areas of high mechanical tension, the mechanotransductory pathway may be attributed to its pathogenesis. We aimed to establish a preclinical platform to elucidate the underlying mechanism of keloid development and its clinical persistence. Methods: We fabricated a mechanically stretchable polydimethylsiloxane cell culture platform; with its mimicry of the in vivo cyclic stretch of skeletal muscles, cells showed higher proliferation compared with conventional modalities. Results: In response to mechanical strain, TGF-β and type 1 collagen showed significant increases, suggesting possible TGF-β/Smad pathway activation via mechanical stimulation. Protein candidates selected by proteomic analysis were evaluated, indicating that key molecules involved in cell signaling and oxidative stress were significantly altered. Additionally, the cytoskeletal network of keloid fibroblasts showed increased expression of its components after periodic mechanical stimulation. Conclusions: Herein, we demonstrated and validated the existing body of knowledge regarding profibrotic mechanotransduction signaling pathways in keloid fibroblasts. Cyclic stretch, as a driving force, could help to decipher the tension-mediated biomechanical processes, leading to the development of optimized therapeutic targets.
- 24 September 2024
- Published by MDPI AG in Biomedicines
- Vol. 12 (10) , 2169
Open AccessIncreased Susceptibility to Mechanical Stretch Drives the Persistence of Keloid Fibroblasts: An Investigation Using a Stretchable PDMS Platform
Background: Keloids are a common fibrotic disease of the skin, with the pathological hallmark of excessive extracellular matrix synthesis due to abnormal fibroblast activity. Since keloids clinically arise in areas of high mechanical tension, the mechanotransductory pathway may be attributed to its pathogenesis. We aimed to establish a preclinical platform to elucidate the underlying mechanism of keloid development and its clinical persistence. Methods: We fabricated a mechanically stretchable polydimethylsiloxane cell culture platform; with its mimicry of the in vivo cyclic stretch of skeletal muscles, cells showed higher proliferation compared with conventional modalities. Results: In response to mechanical strain, TGF-β and type 1 collagen showed significant increases, suggesting possible TGF-β/Smad pathway activation via mechanical stimulation. Protein candidates selected by proteomic analysis were evaluated, indicating that key molecules involved in cell signaling and oxidative stress were significantly altered. Additionally, the cytoskeletal network of keloid fibroblasts showed increased expression of its components after periodic mechanical stimulation. Conclusions: Herein, we demonstrated and validated the existing body of knowledge regarding profibrotic mechanotransduction signaling pathways in keloid fibroblasts. Cyclic stretch, as a driving force, could help to decipher the tension-mediated biomechanical processes, leading to the development of optimized therapeutic targets.
- Open Access
- 27 June 2023
- Published by Wiley in Advanced Functional Materials
- Vol. 33 (26)
Multi‐Functional and Stretchable Thermoelectric Bi2Te3 Fabric for Strain, Pressure, and Temperature‐Sensing (Adv. Funct. Mater. 26/2023)
- 27 June 2023
- Published by Wiley in Advanced Functional Materials
- Vol. 33 (26)
Open AccessMulti‐Functional and Stretchable Thermoelectric Bi2Te3 Fabric for Strain, Pressure, and Temperature‐Sensing (Adv. Funct. Mater. 26/2023)