Arzoo Sharma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Arzoo Sharma has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Pushpendra Singh
Indian Institute of Technology Ropar
2 shared publications - A. Torrento Coello
IJCLab, CNRS, Université Paris-Saclay, Rue Georges Clemenceau, 91405 Orsay, France
1 shared publication - A. Verplancke
OMEGA, CNRS, École Polytechnique, Institut Polytechnique de Paris, Route de Saclay, 91120 Palaiseau, France
1 shared publication B.-Y. Ky
IJCLab, CNRS, Université Paris-Saclay, Rue Georges Clemenceau, 91405 Orsay, France
1 shared publicationB.S. Naidu
1 shared publication- Biswajit Das
Tata Institute of Fundamental Research
1 shared publication
Latest Publications
- 1 April 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (04) , C04014
EICROC: an ASIC to read-out the AC-LGAD sensors for the Electron-Ion Collider (EIC)
The ASIC EICROC is designed to read out the AC-LGAD detectors for the future EIC at Brookhaven National Laboratory (BNL). These detectors should combine excellent temporal (20–30 ps) and spatial (≈20 µm) resolution, enabling a new generation of pixel detectors with precise time measurement. Designing an ASIC to read out the AC-LGAD detectors represents a significant technological challenge. The EICROC ASIC measures and digitizes the charge and the Time-of-Arrival (ToA) with a resolution of 25 ps, transmitting these data to the back-end electronics. The first prototype, EICROC0, was submitted using CMOS 130 nm node in 2022.
- 1 April 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (04) , C04014
EICROC: an ASIC to read-out the AC-LGAD sensors for the Electron-Ion Collider (EIC)
The ASIC EICROC is designed to read out the AC-LGAD detectors for the future EIC at Brookhaven National Laboratory (BNL). These detectors should combine excellent temporal (20–30 ps) and spatial (≈20 µm) resolution, enabling a new generation of pixel detectors with precise time measurement. Designing an ASIC to read out the AC-LGAD detectors represents a significant technological challenge. The EICROC ASIC measures and digitizes the charge and the Time-of-Arrival (ToA) with a resolution of 25 ps, transmitting these data to the back-end electronics. The first prototype, EICROC0, was submitted using CMOS 130 nm node in 2022.
- 17 September 2024
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 196 (10) , 1-24
Investigation of radioactivity and heavy metal levels in soil samples from neutral and vegetation land of Punjab, India
- 17 September 2024
- Published by Springer Nature in Environmental Monitoring and Assessment
- Vol. 196 (10) , 1-24
Investigation of radioactivity and heavy metal levels in soil samples from neutral and vegetation land of Punjab, India