Carolina Castro Gómez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Carolina Castro Gómez has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Helen Johana Ortiz Rojas
Fundación Valle del Lili, Clinical Research Center , Cali , Colombia
2 shared publications Andrea Valencia Orozco
Fundación Valle del Lili, Centro Investigaciones Clínicas, Cra 98 No 18 - 49, Cali 760032, Colombia
1 shared publication- Andrea Valencia-Orozco
Centro de Investigaciones Clínicas, Fundación Valle del Lili, Cali 760032, Colombia
1 shared publication Angela María Murillo Anzola
Fundación Valle del Lili, Medicina Física y Rehabilitación área de Rehabilitación Cardiaca, Cra 98 No 18 - 49, Cali 760032, Colombia
1 shared publicationAngelica Cardona Hernández
Fundación Valle del Lili, Medicina Física y Rehabilitación área de Rehabilitación Cardiaca, Cra 98 No 18 - 49, Cali 760032, Colombia
1 shared publication- Angely Paola Ceron
Physical Medicine and Rehabilitation E.S.E., Hospital Universitario Evaristo Garcia ESE, Cl. 5 #36-00, 760042 Cali, Colombia
1 shared publication
Latest Publications
- Open Access
- 4 November 2026
- Published by Walter de Gruyter GmbH in Advances in Rehabilitation
- Vol. 40 (4) , 1-12
From effort intolerance to functional gain: double product and exercise response in heart failure rehabilitation
Introduction: Heart failure (HF) is associated with exercise intolerance, functional decline and frequent hospitalization. Although cardiac rehabilitation (CR) improves functional capacity, the double product (DP) remains a relevant marker of hemodynamic response. Methods: This retrospective observational study included 79 patients older than 60 years with HF, who completed an outpatient CR program between 2017 and 2023. Functional capacity was assessed with the 6-minute walk test (6MWT) at baseline and after Phase IV, including distance walked, estimated VO 2 and metabolic equivalents (METs). DP and the rating of perceived exertion (RPE) were assessed during sessions across Phases II–IV. Baseline and final 6MWT changes were analyzed using the Wilcoxon signed-rank test, and DP with repeated-measures analysis of variance. Results: Most participants were male (63.3%) and had a high comorbidity burden, mainly hypertension (62%), coronary heart disease (57%) and sedentary lifestyle (55.7%). Significant improvements were observed between baseline and final 6MWT assessments: distance increased from 419 m to 523 m, estimated VO 2 from 10.5 mL/kg/minute to 12.2 mL/kg/minute and METs from 3.0 to 3.5 ( p < 0.001). RPE increased slightly from 11 to 12 ( p = 0.003). DP showed no overall differences across phases ( p = 0.600), but significant effects of time and phase-by-time interaction were found (both p < 0.001). No significant change was observed in Phase II, whereas significant increases occurred in Phases III and IV. Conclusion: CR was associated with improved functional capacity in patients with HF. DP changes varied across phases and may help monitor exercise response. Controlled prospective studies are needed to confirm causality.
- 4 November 2026
- Published by Walter de Gruyter GmbH in Advances in Rehabilitation
- Vol. 40 (4) , 1-12
Open AccessFrom effort intolerance to functional gain: double product and exercise response in heart failure rehabilitation
Introduction: Heart failure (HF) is associated with exercise intolerance, functional decline and frequent hospitalization. Although cardiac rehabilitation (CR) improves functional capacity, the double product (DP) remains a relevant marker of hemodynamic response. Methods: This retrospective observational study included 79 patients older than 60 years with HF, who completed an outpatient CR program between 2017 and 2023. Functional capacity was assessed with the 6-minute walk test (6MWT) at baseline and after Phase IV, including distance walked, estimated VO 2 and metabolic equivalents (METs). DP and the rating of perceived exertion (RPE) were assessed during sessions across Phases II–IV. Baseline and final 6MWT changes were analyzed using the Wilcoxon signed-rank test, and DP with repeated-measures analysis of variance. Results: Most participants were male (63.3%) and had a high comorbidity burden, mainly hypertension (62%), coronary heart disease (57%) and sedentary lifestyle (55.7%). Significant improvements were observed between baseline and final 6MWT assessments: distance increased from 419 m to 523 m, estimated VO 2 from 10.5 mL/kg/minute to 12.2 mL/kg/minute and METs from 3.0 to 3.5 ( p < 0.001). RPE increased slightly from 11 to 12 ( p = 0.003). DP showed no overall differences across phases ( p = 0.600), but significant effects of time and phase-by-time interaction were found (both p < 0.001). No significant change was observed in Phase II, whereas significant increases occurred in Phases III and IV. Conclusion: CR was associated with improved functional capacity in patients with HF. DP changes varied across phases and may help monitor exercise response. Controlled prospective studies are needed to confirm causality.
- Open Access
- 31 January 2026
- Published by Universidad de Santander - UDES in Innovaciencia
- Vol. 14 (1)
Design of a glove dispenser to promote rational glove use and hand hygiene in an intensive care unit
Introduction. Healthcare-associated infections continue to pose a significant challenge in intensive care units (ICUs), where inappropriate glove use and poor hand hygiene can contribute to pathogen transmission and the unnecessary consumption of resources. Gloves represent an essential protective barrier against exposure to potentially infectious biological material, including blood, body fluids, and secretions. Objective. To design, develop, and evaluate a glove dispenser intended to promote appropriate glove use and support hand hygiene practices in an intensive care unit (ICU). Materials and Methods. A technological design study was conducted between January 2023 and January 2024 following a five-phase development process: needs assessment, device specification, concept generation, prototype development and refinement, and final prototype construction. The process incorporated direct clinical observations, feedback from ICU healthcare personnel, iterative usability testing, and pilot implementation in a real clinical setting. Results. A glove dispenser prototype integrated with an alcohol-based hand sanitizer dispenser was developed, incorporating visual prompts based on World Health Organization recommendations to encourage appropriate glove use and hand hygiene. During pilot implementation, 50 healthcare workers participated. Exposure to body fluids was observed in 60% of procedures; glove use was indicated in 72% of cases; 88% of participants used a single pair of gloves per procedure; and 88% reported performing hand hygiene after glove removal. Conclusion. The proposed device represents a technological strategy designed to support appropriate glove use and reinforce hand hygiene practices. Its potential impact on infection prevention and resource optimization should be evaluated in future studies.
- 31 January 2026
- Published by Universidad de Santander - UDES in Innovaciencia
- Vol. 14 (1)
Open AccessDesign of a glove dispenser to promote rational glove use and hand hygiene in an intensive care unit
Introduction. Healthcare-associated infections continue to pose a significant challenge in intensive care units (ICUs), where inappropriate glove use and poor hand hygiene can contribute to pathogen transmission and the unnecessary consumption of resources. Gloves represent an essential protective barrier against exposure to potentially infectious biological material, including blood, body fluids, and secretions. Objective. To design, develop, and evaluate a glove dispenser intended to promote appropriate glove use and support hand hygiene practices in an intensive care unit (ICU). Materials and Methods. A technological design study was conducted between January 2023 and January 2024 following a five-phase development process: needs assessment, device specification, concept generation, prototype development and refinement, and final prototype construction. The process incorporated direct clinical observations, feedback from ICU healthcare personnel, iterative usability testing, and pilot implementation in a real clinical setting. Results. A glove dispenser prototype integrated with an alcohol-based hand sanitizer dispenser was developed, incorporating visual prompts based on World Health Organization recommendations to encourage appropriate glove use and hand hygiene. During pilot implementation, 50 healthcare workers participated. Exposure to body fluids was observed in 60% of procedures; glove use was indicated in 72% of cases; 88% of participants used a single pair of gloves per procedure; and 88% reported performing hand hygiene after glove removal. Conclusion. The proposed device represents a technological strategy designed to support appropriate glove use and reinforce hand hygiene practices. Its potential impact on infection prevention and resource optimization should be evaluated in future studies.
- 8 January 2025
- Published by Elsevier in Current Problems in Cardiology
- Vol. 50 (3) , 102978
Changes in functional capacity of heart failure patients following a cardiac rehabilitation program
- 8 January 2025
- Published by Elsevier in Current Problems in Cardiology
- Vol. 50 (3) , 102978
Changes in functional capacity of heart failure patients following a cardiac rehabilitation program
- Open Access
- 20 September 2024
- Published by EDP Sciences in The Journal of ExtraCorporeal Technology
- Vol. 56 (3) , 128-135
Effects of cardiac rehabilitation in patients with ventricular assist devices: a scoping review
Introduction: Ventricular assist devices represent a treatment option for patients with advanced heart failure, offering control over various haemodynamic variables. Similarly, the prescription of exercise within a cardiac rehabilitation programme for heart failure patients is recommended to reduce symptoms, and hospitalisations, improve cardiorespiratory fitness, and increase exercise tolerance. Therefore, exercise prescription can impact those with ventricular assist devices. Given the limited evidence on exercise-based cardiac rehabilitation programmes for this population, this review aims to describe the most commonly used strategies and their health benefits when physical exercise is included in a cardiac rehabilitation programme for patients with ventricular assist devices. Materials and methods: An exploratory review was conducted through searches in the databases: PubMed, SCOPUS, PeDro, and ScienceDirect. The search was limited to studies published between 2013 and 2023. Filters were applied independently by title, abstract, and full text. The included articles were analysed based on the description of the types of cardiac rehabilitation strategies used in patients with ventricular assist devices. Results: Seven articles were included. Each programme employed a cardiopulmonary exercise test before prescribing physical exercise. The most commonly used strategy was aerobic exercise, predominantly high-intensity interval training (HIIT) with intensities close to 90% of peak VO2, followed by continuous moderate-intensity exercise. Limb strength exercises were included in three programmes. Conclusions: The analysed literature suggests that cardiac rehabilitation in patients with ventricular assist devices is safe and can provide benefits in cardiorespiratory fitness and exercise tolerance. High-intensity interval training is identified as an appropriate strategy for achieving results, offering short-term improvements.
- 20 September 2024
- Published by EDP Sciences in The Journal of ExtraCorporeal Technology
- Vol. 56 (3) , 128-135
Open AccessEffects of cardiac rehabilitation in patients with ventricular assist devices: a scoping review
Introduction: Ventricular assist devices represent a treatment option for patients with advanced heart failure, offering control over various haemodynamic variables. Similarly, the prescription of exercise within a cardiac rehabilitation programme for heart failure patients is recommended to reduce symptoms, and hospitalisations, improve cardiorespiratory fitness, and increase exercise tolerance. Therefore, exercise prescription can impact those with ventricular assist devices. Given the limited evidence on exercise-based cardiac rehabilitation programmes for this population, this review aims to describe the most commonly used strategies and their health benefits when physical exercise is included in a cardiac rehabilitation programme for patients with ventricular assist devices. Materials and methods: An exploratory review was conducted through searches in the databases: PubMed, SCOPUS, PeDro, and ScienceDirect. The search was limited to studies published between 2013 and 2023. Filters were applied independently by title, abstract, and full text. The included articles were analysed based on the description of the types of cardiac rehabilitation strategies used in patients with ventricular assist devices. Results: Seven articles were included. Each programme employed a cardiopulmonary exercise test before prescribing physical exercise. The most commonly used strategy was aerobic exercise, predominantly high-intensity interval training (HIIT) with intensities close to 90% of peak VO2, followed by continuous moderate-intensity exercise. Limb strength exercises were included in three programmes. Conclusions: The analysed literature suggests that cardiac rehabilitation in patients with ventricular assist devices is safe and can provide benefits in cardiorespiratory fitness and exercise tolerance. High-intensity interval training is identified as an appropriate strategy for achieving results, offering short-term improvements.