ABAshfaque Ahmed Bhatti

Ashfaque Ahmed Bhatti

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ashfaque Ahmed Bhatti has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Optimization of Train Grounding System in Dual Traction Power Supply System

    by Ashfaque Ahmed Bhatti, Wei Liu, Mingze Li, Qingan Ma, Qian Xu, Jun Dai, Xiaodong Zhang

    In dual-traction power supply system (DTPSS), an improper value of onboard grounding resistance could result in a larger current distribution, axle end potential, and surge over-voltage (SOV) of the vehicle body (VB) because of the interaction between the AC and DC traction power supply system and the train crossing the neutral sections. Therefore, it is important to carefully select the appropriate value of the resistance and position of the grounding points. This research article proposed the steady-state model of DTPSS to evaluate the current distribution and axle-end potential, and the transient state model of DTPSS to calculate the SOV of the VB of vehicle grounding systems (VGS). To obtain the best optimal solution, the particle swarm optimization (PSO) and the technique for order of preference by similarity to ideal solution (TOPSIS) multi-objective optimization techniques have been implemented. The accuracy and efficiency of the VB current distribution are verified by observing the experimental and simulation results. The proposed VGS optimization technique demonstrates that the VB current distribution has achieved a significant improvement of 24.8% of the total current in the DC section and 21.1% of the total current in the AC section. By observing experimental, simulation, and optimal solutions of transient models in DTPSS, the SOV value was reduce to 33.4% of the total voltage.


  • System Efficient Energy Regulation and Control for Reversible Substations in Urban Rail System

    by Qian Xu, Wei Liu, Juxia Ding, Zhongbei Tian, Jian Zhang, Xiaodong Zhang, Ashfaque Ahmed Bhatti

    The system efficiency of reversible substations (RSSs) in urban rail transit power supply systems has garnered significant attention. In particular, reverse power flow from the main substation (MS) has been observed in the real world, adversely impacting system efficiency. This article proposes a novel power supply structure for RSSs that effectively reduces reverse power flow. To further enhance system efficiency, an optimal model is established by leveraging the control characteristics of RSSs. Then, a system efficiency energy regulation and control framework considering complex scenarios is presented, with the lowest system losses as the optimization objective. The modified Cheetah Optimizer algorithm is adopted to optimize the control parameters of reversible converters (RCs). Simulations of actual engineering cases are conducted, and the results demonstrate the effectiveness of the proposed power supply solution and energy regulation control in various scenarios. The proposed method can improve energy efficiency by up to 3.25% and 2% compared with nonoptimized and existing offline optimized methods, and this value varies depending on the scenario. Additionally, performance analysis and evaluation highlight the fundamentals of energy regulation in enhancing system efficiency, including balancing bus load, appropriately increasing catenary voltage, and adjusting the proportion of regenerative braking energy (RBE) between the ac and dc sides based on different situations.


  • A Field-Circuit Coupling Diffusion Model for Stray Current of DC Metro System

    by Wei Liu, Zhe Pan, Yuning Tang, Linjie Zhou, Ashfaque Ahmed Bhatti, Jianbang Niu

    Stray current in the DC metro system is commonly assessed using circuit or electric field models. Circuit models cannot accurately represent the stray current diffusion due to the track bed and soil resistivity effect on rail-to-earth resistance (RE). Meanwhile, electric field models lack detailed device modeling, which hampers their ability to comprehensive stray current analyses. To overcome these limitations, a field-circuit coupling diffusion model for stray current is proposed. The electric field submodel is established through the direct boundary element method (DBEM) for the metro reflux system (RS) and obtaining the mutual resistance matrix. The circuit submodel of the DC traction power system (DPS) is established based on the behavior characteristics of the RS devices. The dynamic stray current diffusion is obtained by coupling the two submodels through the mutual resistance matrix. The accuracy and efficiency in solving large systems with massive textures of the proposed model are verified by comparing them with the field test data and other existing methods. The case shows that strengthening the RE for a length of 500-meter on both sides of each traction power substation (TPS) can effectively reduce the earth potential gradient along the metro line.


  • A Novel Built in Metal Foil Sensor for PD Detection of HV Cables

    by Hongdong Lin, Yijiang Wu, Ganjun Wang, Wenze Li, Xiaosheng Peng, Jinshu Li, Ashfaque Ahmed Bhatti

    Partial Discharge (PD) signal is an important parameter reflecting the insulation condition of High Voltage(HV) cables. Meanwhile, PD detection and monitoring is an effective way to ensure the safe and stable operation of the HV cables. Due to the limited bandwidth and the poor anti-interference ability of the current PD sensors, there are a lot of interference signals in the detected PD signals. To overcome the challenge, a novel built-in metal foil sensor for PD detection of HV cables is presented in the paper. The influencing factors of the PD detecting sensitivity, which are the single electrode and the two electrodes, the size of the electrodes, the shape of the single electrode and the distance between the two electrodes, are evaluated. The experimental data is accumulated to determine the parameters of the metal foil sensor. Experimental results show that the built-in metal foil sensor has excellent efficiency in PD signal reception in both laboratory and experimental base, which is applicable for on-line PD detecting of HV cables.