Shinji Imade
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Shinji Imade has a total of 85 co-authors. Here are the top co-authors by number of shared publications:
Yuji Uchio
Department of Orthopaedic Surgery, Shimane University Faculty of Medicine, Shimane, Japan
14 shared publicationsSuguru Kuwata
Department of Orthopaedic Surgery, Shimane University Faculty of Medicine, Izumo, Japan
4 shared publicationsMasaru Kadowaki
Assistant Professor, Department of Orthopaedic Surgery, Shimane University Faculty of Medicine, Shimane, Japan
3 shared publicationsNobuyuki Kumahashi
Department of Orthopaedic Surgery, Shimane University Faculty of Medicine, Izumo, Japan
3 shared publicationsRyuji Mori
3 shared publicationsWataru Miyamoto
3 shared publications
Latest Publications
- 15 October 2025
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 31 (2) , 392-400
Association between hallux valgus pain and foot-related quality of life: The hallux valgus and pain epidemiology study
- 15 October 2025
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 31 (2) , 392-400
Association between hallux valgus pain and foot-related quality of life: The hallux valgus and pain epidemiology study
- 5 September 2025
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 31 (2) , 380-386
Epidemiology and risk factors of hallux valgus in Japanese population: HAPPI study
- 5 September 2025
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 31 (2) , 380-386
Epidemiology and risk factors of hallux valgus in Japanese population: HAPPI study
- 1 April 2025
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 15 (2)
Reconstruction of a Medial Malleolus with a Computerized Numerical Control Multitasking Machine for Bone Machining
Case: A 31-year-old Brazilian man with a multioperated right medial malleolus defect underwent anatomical ankle reconstruction with an iliac autograft. The bone graft was designed using computer-aided technology, based on the healthy side. Bone graft machining was performed using a Computerized Numerical Control (CNC) multitasking machine in a sterilized environment. Two years postoperatively, the patient had mild ankle discomfort but little difficulty performing daily activities. Computed tomography confirmed graft union, and arthroscopy revealed cartilage-like tissue on the articular surface of the reconstructed medial malleolus. Conclusion: Precise bone machining using a CNC multitasking machine may enhance the accuracy of anatomical joint reconstructions.
- 1 April 2025
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 15 (2)
Reconstruction of a Medial Malleolus with a Computerized Numerical Control Multitasking Machine for Bone Machining
Case: A 31-year-old Brazilian man with a multioperated right medial malleolus defect underwent anatomical ankle reconstruction with an iliac autograft. The bone graft was designed using computer-aided technology, based on the healthy side. Bone graft machining was performed using a Computerized Numerical Control (CNC) multitasking machine in a sterilized environment. Two years postoperatively, the patient had mild ankle discomfort but little difficulty performing daily activities. Computed tomography confirmed graft union, and arthroscopy revealed cartilage-like tissue on the articular surface of the reconstructed medial malleolus. Conclusion: Precise bone machining using a CNC multitasking machine may enhance the accuracy of anatomical joint reconstructions.
- 24 September 2024
- Published by Elsevier in Journal of Biomechanics
- Vol. 176, 112321
Investigation of the appropriate thread depth for bioabsorbable screws
- 24 September 2024
- Published by Elsevier in Journal of Biomechanics
- Vol. 176, 112321
Investigation of the appropriate thread depth for bioabsorbable screws
- 27 July 2024
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 30 (3) , 513-517
Osteoporosis should be evaluated by bone mineral density at the combination of the lumbar spine and ipsilateral femoral neck in female patients with knee osteoarthritis scheduled for knee arthroplasty: A retrospective observational study
- 27 July 2024
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 30 (3) , 513-517
Osteoporosis should be evaluated by bone mineral density at the combination of the lumbar spine and ipsilateral femoral neck in female patients with knee osteoarthritis scheduled for knee arthroplasty: A retrospective observational study
- 17 April 2024
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 30 (2) , 405-412
Effect of bone density on the drill-hole diameter made by a cannulated drill bit in cancellous bone
- 17 April 2024
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 30 (2) , 405-412
Effect of bone density on the drill-hole diameter made by a cannulated drill bit in cancellous bone
- 8 August 2022
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 28 (5) , 1143-1148
Relationship between thread depth and fixation strength in cancellous bone screw
- 8 August 2022
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 28 (5) , 1143-1148
Relationship between thread depth and fixation strength in cancellous bone screw
- Open Access
- 1 January 2019
- Published by SAGE Publications in Journal of Orthopaedic Surgery
- Vol. 27 (1)
Effect of the positional relationship between the interference screw and the tendon graft in the bone tunnel in ligament reconstruction
To reveal the effects of the positional and length relationships between the interference screws (ISs) and the tendon graft in the bone tunnel on the fixation strength in ligament reconstruction. We compared three IS positions on the anterior (the Anterior group) or posterior (the Posterior group) or side (the Side group) of the tendon graft in relation to the pullout direction. The tendon graft was pulled at 0°, 30°, 60°, and 90° to the bone tunnel, and the maximum pullout load at each angle was compared among the groups. We also investigated the relationship between the length of the tendon graft and the length of the IS in the bone tunnel. The direction of the pullout force was the same as that of the Anterior group, and the maximum load was compared between groups in which the tendon graft was longer or shorter than the IS. The maximum loads of the Anterior group were significantly greater than those of the Posterior and Side groups at the traction angles of 30° and 60°, respectively. An IS shorter than the tendon graft was found to provide significantly superior fixation strength compared to an IS longer than the tendon graft. Better fixation strength was achieved when the IS was placed on the side of the anchorage tunnel on which the tendon graft was loaded and the IS was shorter than the tendon graft.
- 1 January 2019
- Published by SAGE Publications in Journal of Orthopaedic Surgery
- Vol. 27 (1)
Open AccessEffect of the positional relationship between the interference screw and the tendon graft in the bone tunnel in ligament reconstruction
To reveal the effects of the positional and length relationships between the interference screws (ISs) and the tendon graft in the bone tunnel on the fixation strength in ligament reconstruction. We compared three IS positions on the anterior (the Anterior group) or posterior (the Posterior group) or side (the Side group) of the tendon graft in relation to the pullout direction. The tendon graft was pulled at 0°, 30°, 60°, and 90° to the bone tunnel, and the maximum pullout load at each angle was compared among the groups. We also investigated the relationship between the length of the tendon graft and the length of the IS in the bone tunnel. The direction of the pullout force was the same as that of the Anterior group, and the maximum load was compared between groups in which the tendon graft was longer or shorter than the IS. The maximum loads of the Anterior group were significantly greater than those of the Posterior and Side groups at the traction angles of 30° and 60°, respectively. An IS shorter than the tendon graft was found to provide significantly superior fixation strength compared to an IS longer than the tendon graft. Better fixation strength was achieved when the IS was placed on the side of the anchorage tunnel on which the tendon graft was loaded and the IS was shorter than the tendon graft.
- 1 May 2018
- Published by Elsevier in The Journal of Foot and Ankle Surgery
- Vol. 57 (3) , 600-604
Atraumatic Spontaneous Achilles Tendon Rupture in Patients Receiving Oral Corticosteroids Treated With the Modified Side-Locking Loop Suture Technique
- 1 May 2018
- Published by Elsevier in The Journal of Foot and Ankle Surgery
- Vol. 57 (3) , 600-604
Atraumatic Spontaneous Achilles Tendon Rupture in Patients Receiving Oral Corticosteroids Treated With the Modified Side-Locking Loop Suture Technique
- 1 July 2014
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 19 (4) , 686-689
Medial ankle impingement syndrome with talocalcaneal coalition treated by arthroscopy-assisted resection: a case report
- 1 July 2014
- Published by Elsevier in Journal of Orthopaedic Science
- Vol. 19 (4) , 686-689
Medial ankle impingement syndrome with talocalcaneal coalition treated by arthroscopy-assisted resection: a case report