Teodor Veres
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Teodor Veres has a total of 70 co-authors. Here are the top co-authors by number of shared publications:
- Lidija Malic
Life Sciences Division, National Research Council of Canada, 75 de Mortagne Boulevard, Boucherville, QC J4B 6Y4, Canada
5 shared publications - Daniel Brassard
Medical Devices Research Centre, National Research Council of Canada, 75 de Mortagne Boulevard, Boucherville, QC, J4B 6Y4, Canada
4 shared publications Ljuboje Lukic
National Research Council of Canada 75 de Mortagne Boucherville QC J4B 6Y4 Canada
4 shared publications- Matthias Geissler
Life Sciences Division, National Research Council of Canada, 75 de Mortagne Boulevard, Boucherville, QC J4B 6Y4, Canada
4 shared publications - Byeong-Ui Moon
National Research Council of Canada, 75 de Mortagne, Boucherville, Quebec, J4B 6Y4, Canada
3 shared publications Christina Nassif
Medical Devices Research Centre, National Research Council of Canada, 75 de Mortagne Boulevard, Boucherville, QC, J4B 6Y4, Canada
3 shared publications
Latest Publications
- Open Access
- 29 May 2026
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 26 (15) , 4289-4299
Adeno-associated viral vector purification using a centrifugal microfluidic system: towards workflow automation for low-volume sample processing
AAV vectors are purified using a polymer-based microfluidic cartridge that features an embedded solid-phase extraction matrix and a layout that is compatible with workflow automation and low-volume sample processing.
- 29 May 2026
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 26 (15) , 4289-4299
Open AccessAdeno-associated viral vector purification using a centrifugal microfluidic system: towards workflow automation for low-volume sample processing
AAV vectors are purified using a polymer-based microfluidic cartridge that features an embedded solid-phase extraction matrix and a layout that is compatible with workflow automation and low-volume sample processing.
- Open Access
- 3 March 2026
- Published by IOP Publishing in Biofabrication
- Vol. 18 (2)
In situ printing of biphasic jammed inks for conformal deposition on convex anatomical surfaces, with microgravity validation
Rapid in situ bioprinting on complex, human-scale anatomical surfaces remains a key challenge for point-of-care use. Precise biomaterial ink or bioink deposition is required not only in operating theatres but also in resource-limited environments such as rural clinics and spaceflight missions. Here, we present a strategy for rapidly and conformally delivering biphasic biomaterial inks and bioinks composed of jammed gelatin microgels optionally suspended in a cell laden fibrinogen matrix. The formulation exhibits yield-stress behavior, preserves shape fidelity immediately after extrusion independent of gelation kinetics, maintains cell viability above 85%, and supports proliferation. The bioink is delivered through multinozzle printheads with 16 exit nozzles. During deposition at 450 mm²·s⁻¹, a ladder-rung channel architecture provided more uniform area coverage compared with a bifurcated design. Two printhead configurations were investigated: (1) a pneumatically actuated soft-robotic printhead with real-time adaptation to physiologically relevant convex surface curvatures, and (2) a rigid printhead integrated with a handheld bioprinter that enabled the first demonstration of biphasic jammed biomaterial ink deposition in microgravity. Considered radii of curvature and gravitational accelerations ranged from 10–100 mm and 0–1 g, respectively. Together with fibrin network formation, these results establish a translationally relevant biofabrication framework for in situ bioprinting in regenerative medicine, austere trauma care, and space-based healthcare.
- 3 March 2026
- Published by IOP Publishing in Biofabrication
- Vol. 18 (2)
Open AccessIn situ printing of biphasic jammed inks for conformal deposition on convex anatomical surfaces, with microgravity validation
Rapid in situ bioprinting on complex, human-scale anatomical surfaces remains a key challenge for point-of-care use. Precise biomaterial ink or bioink deposition is required not only in operating theatres but also in resource-limited environments such as rural clinics and spaceflight missions. Here, we present a strategy for rapidly and conformally delivering biphasic biomaterial inks and bioinks composed of jammed gelatin microgels optionally suspended in a cell laden fibrinogen matrix. The formulation exhibits yield-stress behavior, preserves shape fidelity immediately after extrusion independent of gelation kinetics, maintains cell viability above 85%, and supports proliferation. The bioink is delivered through multinozzle printheads with 16 exit nozzles. During deposition at 450 mm²·s⁻¹, a ladder-rung channel architecture provided more uniform area coverage compared with a bifurcated design. Two printhead configurations were investigated: (1) a pneumatically actuated soft-robotic printhead with real-time adaptation to physiologically relevant convex surface curvatures, and (2) a rigid printhead integrated with a handheld bioprinter that enabled the first demonstration of biphasic jammed biomaterial ink deposition in microgravity. Considered radii of curvature and gravitational accelerations ranged from 10–100 mm and 0–1 g, respectively. Together with fibrin network formation, these results establish a translationally relevant biofabrication framework for in situ bioprinting in regenerative medicine, austere trauma care, and space-based healthcare.
- Open Access
- 1 January 2026
- Published by American Association for Cancer Research (AACR) in Cancer Research Communications
- Vol. 6 (1) , 143-151
Extrachromosomal microDNA Signature as a Candidate Biomarker in Pediatric Acute Lymphoblastic Leukemia
Acute lymphoblastic leukemia (ALL) is the most common childhood cancer. Despite improved therapies, refractory and relapsed ALL remain the leading cause of cancer-related mortality in children. There is a need for accessible biomarkers for frequent, minimally invasive disease monitoring and prompt intervention. MicroDNA is a novel extrachromosomal DNA that preferentially originates from gene segments with high transcriptional activity and/or increased chromatin accessibility. We investigated whether microDNA-producing genes repertoire changes in a disease-dependent manner. We characterized microDNAs in 52 paired bone marrow (BM) and plasma samples from pediatric patients with ALL at diagnosis, relapse, and remission. No difference in the length or number of microDNA was noted across stages, but comparative analysis of microDNA profiles led to the identification of microDNA gene panels associated with active disease. The relative distribution of these genes was significantly different from that expected by chance (P < 0.0001). Analyses of BM samples identified a signature comprising 289 distinct microDNA-producing genes present in multiple patients at diagnosis and relapse but absent in remission. The best biomarker candidates were 11 microDNA-producing genes identified also in plasma samples at diagnosis and overrepresented in patients who relapsed (P = 0.006). MicroDNA from the same genes was confirmed in relapse plasma samples. All signature genes are known to be involved in cancer proliferation or drug response. MicroDNA seems to be a candidate for a novel class of biomarkers for ALL, with the potential to improve precision diagnostics, particularly through their identification in plasma samples. Further validation in an independent cohort of patients is warranted. Significance: Despite high cure rates, 10% to 15% of pediatric patients with ALL experience relapse. We identified a plasma-detectable microDNA signature from 11 genes that persists from diagnosis through relapse but disappears in remission. These findings demonstrate the potential of microDNA profiles as prognostic biomarkers in pediatric ALL, enabling noninvasive monitoring of disease status and risk stratification.
- 1 January 2026
- Published by American Association for Cancer Research (AACR) in Cancer Research Communications
- Vol. 6 (1) , 143-151
Open AccessExtrachromosomal microDNA Signature as a Candidate Biomarker in Pediatric Acute Lymphoblastic Leukemia
Acute lymphoblastic leukemia (ALL) is the most common childhood cancer. Despite improved therapies, refractory and relapsed ALL remain the leading cause of cancer-related mortality in children. There is a need for accessible biomarkers for frequent, minimally invasive disease monitoring and prompt intervention. MicroDNA is a novel extrachromosomal DNA that preferentially originates from gene segments with high transcriptional activity and/or increased chromatin accessibility. We investigated whether microDNA-producing genes repertoire changes in a disease-dependent manner. We characterized microDNAs in 52 paired bone marrow (BM) and plasma samples from pediatric patients with ALL at diagnosis, relapse, and remission. No difference in the length or number of microDNA was noted across stages, but comparative analysis of microDNA profiles led to the identification of microDNA gene panels associated with active disease. The relative distribution of these genes was significantly different from that expected by chance (P < 0.0001). Analyses of BM samples identified a signature comprising 289 distinct microDNA-producing genes present in multiple patients at diagnosis and relapse but absent in remission. The best biomarker candidates were 11 microDNA-producing genes identified also in plasma samples at diagnosis and overrepresented in patients who relapsed (P = 0.006). MicroDNA from the same genes was confirmed in relapse plasma samples. All signature genes are known to be involved in cancer proliferation or drug response. MicroDNA seems to be a candidate for a novel class of biomarkers for ALL, with the potential to improve precision diagnostics, particularly through their identification in plasma samples. Further validation in an independent cohort of patients is warranted. Significance: Despite high cure rates, 10% to 15% of pediatric patients with ALL experience relapse. We identified a plasma-detectable microDNA signature from 11 genes that persists from diagnosis through relapse but disappears in remission. These findings demonstrate the potential of microDNA profiles as prognostic biomarkers in pediatric ALL, enabling noninvasive monitoring of disease status and risk stratification.
- Open Access
- 7 October 2025
- Published by Wiley in Advanced Materials
- Vol. 38 (13) , e06398
PiP‐Plex: A Particle‐in‐Particle System for Multiplexed Quantification of Proteins Secreted by Single Cells
Cell signaling is modulated by the secretion of various proteins, which can be used to infer a cell's phenotype. However, these proteins cannot be readily detected in multiplex by commonly used methods at the single‐cell level. Here we present PiP‐plex a particles‐in‐particle (PiPs) system for multiplex protein secretion analysis by confocal microscopy. PiP‐plex‐comprises (i) fluorescence intensity barcoded microparticles (BMPs) co‐entrapped with (ii) a single cell inside an alginate hydrogel particle. We found that PiPs maintained >90% cellular viability and allowed live cells retrieval. A seven‐plex fluorescent barcoding and concomitant sandwich immunoassay in PiPs was developed with limits of detection ranging from 0.8 pg mL −1 to 2 ng mL −1 depending on the protein. PiP‐plex assays were benchmarked with bulk immunoassays and found to rival or outperform them. Proteins secreted by single THP‐1 cells upon exposure to lipopolysaccharide were measured by PiP‐plex and varying cell responses detected, including a significant increase in MIP‐1α, TNF‐α, and IL‐17A; MIP‐1α and IL‐17A were the most frequently secreted cytokines, while other cytokines were typically co‐secreted. Using PiP‐plex, we analyzed ≈750 THP‐1 cells, showcasing its potential for characterizing cells and cell‐based therapeutics for e.g. cancer immunotherapies.
- 7 October 2025
- Published by Wiley in Advanced Materials
- Vol. 38 (13) , e06398
Open AccessPiP‐Plex: A Particle‐in‐Particle System for Multiplexed Quantification of Proteins Secreted by Single Cells
Cell signaling is modulated by the secretion of various proteins, which can be used to infer a cell's phenotype. However, these proteins cannot be readily detected in multiplex by commonly used methods at the single‐cell level. Here we present PiP‐plex a particles‐in‐particle (PiPs) system for multiplex protein secretion analysis by confocal microscopy. PiP‐plex‐comprises (i) fluorescence intensity barcoded microparticles (BMPs) co‐entrapped with (ii) a single cell inside an alginate hydrogel particle. We found that PiPs maintained >90% cellular viability and allowed live cells retrieval. A seven‐plex fluorescent barcoding and concomitant sandwich immunoassay in PiPs was developed with limits of detection ranging from 0.8 pg mL −1 to 2 ng mL −1 depending on the protein. PiP‐plex assays were benchmarked with bulk immunoassays and found to rival or outperform them. Proteins secreted by single THP‐1 cells upon exposure to lipopolysaccharide were measured by PiP‐plex and varying cell responses detected, including a significant increase in MIP‐1α, TNF‐α, and IL‐17A; MIP‐1α and IL‐17A were the most frequently secreted cytokines, while other cytokines were typically co‐secreted. Using PiP‐plex, we analyzed ≈750 THP‐1 cells, showcasing its potential for characterizing cells and cell‐based therapeutics for e.g. cancer immunotherapies.
- Open Access
Conformal Bioprinting of Bi-phasic Jammed Bioinks, Independent of Gravity, Orientation, and Curvature
Rapid in situ bioprinting on complex, human-scale anatomical surfaces remain a key challenge for clinical translation. Here, we present a gravity-independent, conformal bioprinting strategy using bi-phasic granular bioink and multinozzle printheads capable of adapting to arbitrary surface curvatures. The bioink comprised of jammed gelatin microgels suspended in a fibrinogen matrix exhibits yield-stress behavior to maintain shape fidelity after extrusion while supporting cell viability and proliferation. Two monolithic multinozzle printhead architectures with identical bioink delivery networks were evaluated: (1) a rigid configuration for handheld bioprinting and (2) a soft robotic variant capable of real-time curvature adaptation via pneumatic actuation. Microgravity experiments aboard a parabolic flight confirmed successful bioink deposition under ∼0 g conditions. A ladder-rung microfluidic architecture ensured uniform bioink delivery across printhead nozzles, improving deposition consistency. In situ bioprinting on anatomical facial phantoms confirmed conformal, high-throughput (deposition at 20 mm·s -1 ) deposition of bioink over physiologically relevant curvatures, both with and without cells. Cell-laden constructs retained >85% cell viability post-printing and supported proliferation. This work introduces a scalable bioprinting platform suitable for clinical, remote, and deep-space environments, enabling autonomous tissue fabrication. The curvature-adaptive printhead advances current in situ bioprinting capabilities, facilitating the generation of personalized grafts with complex anatomical geometries.
Open AccessConformal Bioprinting of Bi-phasic Jammed Bioinks, Independent of Gravity, Orientation, and Curvature
Rapid in situ bioprinting on complex, human-scale anatomical surfaces remain a key challenge for clinical translation. Here, we present a gravity-independent, conformal bioprinting strategy using bi-phasic granular bioink and multinozzle printheads capable of adapting to arbitrary surface curvatures. The bioink comprised of jammed gelatin microgels suspended in a fibrinogen matrix exhibits yield-stress behavior to maintain shape fidelity after extrusion while supporting cell viability and proliferation. Two monolithic multinozzle printhead architectures with identical bioink delivery networks were evaluated: (1) a rigid configuration for handheld bioprinting and (2) a soft robotic variant capable of real-time curvature adaptation via pneumatic actuation. Microgravity experiments aboard a parabolic flight confirmed successful bioink deposition under ∼0 g conditions. A ladder-rung microfluidic architecture ensured uniform bioink delivery across printhead nozzles, improving deposition consistency. In situ bioprinting on anatomical facial phantoms confirmed conformal, high-throughput (deposition at 20 mm·s -1 ) deposition of bioink over physiologically relevant curvatures, both with and without cells. Cell-laden constructs retained >85% cell viability post-printing and supported proliferation. This work introduces a scalable bioprinting platform suitable for clinical, remote, and deep-space environments, enabling autonomous tissue fabrication. The curvature-adaptive printhead advances current in situ bioprinting capabilities, facilitating the generation of personalized grafts with complex anatomical geometries.
- Open Access
PiP-plex: A Particle-in-Particle System for Multiplexed Quantification of Proteins Secreted by Single Cells
Cell signaling is modulated by the secretion of various proteins, which can be used to infer a cell’s phenotype. However, these proteins cannot be readily detected in multiplex by commonly used methods at the single cell level. Here, we present PiP-plex, a particles-in-particle (PiPs) system comprising (i) fluorescence intensity barcoded microparticles (BMPs) co-entrapped with (ii) a single cell inside an alginate hydrogel particle for multiplex protein secretion analysis by confocal microscopy. We show that developed PiPs maintained >90 % cellular viability and allowed live cells retrieval. A seven-plex fluorescent barcoding and concomitant sandwich immunoassay in PiPs were implemented with limits of detection ranging from 0.8 pg mL -1 to 2 ng mL -1 depending on the protein. PiP-plex assays were benchmarked with bulk immunoassays and found to rival or outperform them. We applied PiP-plex to analyze protein secreted by THP-1 cells upon exposure to lipopolysaccharide and detected varying cell responses, with a significant increase in MIP-1α, TNF-α and IL-17A. Multivariate analysis revealed that the majority of stimulated cells secreted either MIP-1α or IL-17A, while other cytokines were typically co-secreted. Using PiP-plex, we analyzed ∼750 THP-1 cells, showcasing its potential for characterizing cells and cell-based therapeutics for cancer immunotherapies.
Open AccessPiP-plex: A Particle-in-Particle System for Multiplexed Quantification of Proteins Secreted by Single Cells
Cell signaling is modulated by the secretion of various proteins, which can be used to infer a cell’s phenotype. However, these proteins cannot be readily detected in multiplex by commonly used methods at the single cell level. Here, we present PiP-plex, a particles-in-particle (PiPs) system comprising (i) fluorescence intensity barcoded microparticles (BMPs) co-entrapped with (ii) a single cell inside an alginate hydrogel particle for multiplex protein secretion analysis by confocal microscopy. We show that developed PiPs maintained >90 % cellular viability and allowed live cells retrieval. A seven-plex fluorescent barcoding and concomitant sandwich immunoassay in PiPs were implemented with limits of detection ranging from 0.8 pg mL -1 to 2 ng mL -1 depending on the protein. PiP-plex assays were benchmarked with bulk immunoassays and found to rival or outperform them. We applied PiP-plex to analyze protein secreted by THP-1 cells upon exposure to lipopolysaccharide and detected varying cell responses, with a significant increase in MIP-1α, TNF-α and IL-17A. Multivariate analysis revealed that the majority of stimulated cells secreted either MIP-1α or IL-17A, while other cytokines were typically co-secreted. Using PiP-plex, we analyzed ∼750 THP-1 cells, showcasing its potential for characterizing cells and cell-based therapeutics for cancer immunotherapies.
- Open Access
Using machine learning and centrifugal microfluidics at the point-of-need to predict clinical deterioration of patients with suspected sepsis within the first 24 h.
Sepsis is the body’s dysfunctional response to infection associated with organ failure. Delays in diagnosis have a substantial impact on survival. Herein, samples from 586 in-house patients were used in conjunction with machine learning and cross-validation to narrow a gene expression signature of immune cell reprogramming to predict clinical deterioration in patients with suspected sepsis within the first 24 hours (h) of clinical presentation using just six genes (Sepset). The accuracy of the test (∼90% in early intensive care unit (ICU) and 70% in emergency room patients) was validated in 3,178 patients from existing independent cohorts. A real-time reverse transcriptase polymerase chain reaction (RT-PCR)-based test was shown to have a 98% sensitivity in >230 patients to predict worsening of the sequential organ failure scores or admission to the ICU within the first 24 h following Sepset detection. A stand-alone centrifugal microfluidic instrument that integrates the entire automated workflow for detection of the Sepset classifier in whole blood using digital droplet PCR was developed and tested. This PREcision meDIcine for CriTical care (PREDICT) system had a high sensitivity of 92%, specificity of 89%, and an overall accuracy of 88% in identifying the risk of imminent clinical deterioration in patients with suspected sepsis. Description of Graphic Abstract Feature reduction and development of a gene classifier that predicts deterioration risk groups in patients starts with in-house RNA sequencing data from patient collected from a heterogenous cohort of patients with suspected sepsis (top left) to reduce our original published gene signature down to 6-genes (Sepset), for which expression could be related to 2 housekeeping genes. Feature selection was performed using machine learning (ML) and AI and the classifier validated in samples from published transcriptomic studies. Molecular assay is then developed by designing and testing primer/probe sequences specific to the target genes using digital droplet PCR. In parallel, sample-to-answer microfluidic platform and cartridges are developed (bottom right) and analytical performance of multiplex quantitative assay is tested. Prognostic enrichment is obtained by analyzing the results using ML algorithm to determine the percent likelihood of significant clinical deterioration within the immediate next 24 h. The deployment of PREDICT platform (center) at the point-of-care is anticipated to aid in triage and management of prospective sepsis within the first 3 h of clinical presentation.
Open AccessUsing machine learning and centrifugal microfluidics at the point-of-need to predict clinical deterioration of patients with suspected sepsis within the first 24 h.
Sepsis is the body’s dysfunctional response to infection associated with organ failure. Delays in diagnosis have a substantial impact on survival. Herein, samples from 586 in-house patients were used in conjunction with machine learning and cross-validation to narrow a gene expression signature of immune cell reprogramming to predict clinical deterioration in patients with suspected sepsis within the first 24 hours (h) of clinical presentation using just six genes (Sepset). The accuracy of the test (∼90% in early intensive care unit (ICU) and 70% in emergency room patients) was validated in 3,178 patients from existing independent cohorts. A real-time reverse transcriptase polymerase chain reaction (RT-PCR)-based test was shown to have a 98% sensitivity in >230 patients to predict worsening of the sequential organ failure scores or admission to the ICU within the first 24 h following Sepset detection. A stand-alone centrifugal microfluidic instrument that integrates the entire automated workflow for detection of the Sepset classifier in whole blood using digital droplet PCR was developed and tested. This PREcision meDIcine for CriTical care (PREDICT) system had a high sensitivity of 92%, specificity of 89%, and an overall accuracy of 88% in identifying the risk of imminent clinical deterioration in patients with suspected sepsis. Description of Graphic Abstract Feature reduction and development of a gene classifier that predicts deterioration risk groups in patients starts with in-house RNA sequencing data from patient collected from a heterogenous cohort of patients with suspected sepsis (top left) to reduce our original published gene signature down to 6-genes (Sepset), for which expression could be related to 2 housekeeping genes. Feature selection was performed using machine learning (ML) and AI and the classifier validated in samples from published transcriptomic studies. Molecular assay is then developed by designing and testing primer/probe sequences specific to the target genes using digital droplet PCR. In parallel, sample-to-answer microfluidic platform and cartridges are developed (bottom right) and analytical performance of multiplex quantitative assay is tested. Prognostic enrichment is obtained by analyzing the results using ML algorithm to determine the percent likelihood of significant clinical deterioration within the immediate next 24 h. The deployment of PREDICT platform (center) at the point-of-care is anticipated to aid in triage and management of prospective sepsis within the first 3 h of clinical presentation.
- Open Access
- 11 September 2024
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 24 (20) , 4755-4765
Sample-to-answer centrifugal microfluidic droplet PCR platform for quantitation of viral load
Fully automated sample-to-answer ddPCR for virus quantification is implemented on a centrifugal platform with active pneumatic pumping comprising wireless heaters and miniaturized fluorescence imaging system.
- 11 September 2024
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 24 (20) , 4755-4765
Open AccessSample-to-answer centrifugal microfluidic droplet PCR platform for quantitation of viral load
Fully automated sample-to-answer ddPCR for virus quantification is implemented on a centrifugal platform with active pneumatic pumping comprising wireless heaters and miniaturized fluorescence imaging system.
- Open Access
- 2 July 2024
- Published by Royal Society of Chemistry (RSC) in Reaction Chemistry & Engineering
- Vol. 9 (10) , 2584-2598
Scalable preparation of macroporous collagen microgels by air bubble-induced breakup and ice templating
Collagen I, the most abundant protein of the extracellular matrix, has found widespread use in three-dimensional cell culture, and increasingly also in bioprinting and biofabrication applications. However, several limitations remain, such as the capacity to locally recapitulate the multiscale organization of collagen in native tissues. Bioprinting cellular collagen structures with high feature fidelity so far either requires a more rapidly gelling biopolymer to be added or an acellular collagen structure to be defined before the delivery of cells. Here, we report the flow synthesis of macroporous collagen microgels (MCMs) that serve as building blocks for granular bioinks. Obtained bioinks offer excellent printability, provide an avenue to faithfully recapitulate the multiscale collagen organization of native tissues, and overcome the aforementioned limitations. Viscous collagen solutions with concentrations as high as 10 mg ml−1 are consistently converted into droplets using a parallelized microfluidic device via air bubble induced droplet breakup into a continuous oil phase. MCMs are obtained by inducing gelation, oil removal, and washing, and incorporating internal pores of tunable size via ice templating at freezing rates between 0.1 and 10 °C min−1. Independent control over the MCM diameter (175–250 μm) and porosity (58–76%) allows the extracellular matrix structure to be tailored to different tissue engineering applications. The wall structures within MCMs share similarities with the highly compacted and recapitulated collagen porosity in native tissues. This approach in the future can be used to 3D print more complicated biomimetic structures that require cell positioning during printing.
- 2 July 2024
- Published by Royal Society of Chemistry (RSC) in Reaction Chemistry & Engineering
- Vol. 9 (10) , 2584-2598
Open AccessScalable preparation of macroporous collagen microgels by air bubble-induced breakup and ice templating
Collagen I, the most abundant protein of the extracellular matrix, has found widespread use in three-dimensional cell culture, and increasingly also in bioprinting and biofabrication applications. However, several limitations remain, such as the capacity to locally recapitulate the multiscale organization of collagen in native tissues. Bioprinting cellular collagen structures with high feature fidelity so far either requires a more rapidly gelling biopolymer to be added or an acellular collagen structure to be defined before the delivery of cells. Here, we report the flow synthesis of macroporous collagen microgels (MCMs) that serve as building blocks for granular bioinks. Obtained bioinks offer excellent printability, provide an avenue to faithfully recapitulate the multiscale collagen organization of native tissues, and overcome the aforementioned limitations. Viscous collagen solutions with concentrations as high as 10 mg ml−1 are consistently converted into droplets using a parallelized microfluidic device via air bubble induced droplet breakup into a continuous oil phase. MCMs are obtained by inducing gelation, oil removal, and washing, and incorporating internal pores of tunable size via ice templating at freezing rates between 0.1 and 10 °C min−1. Independent control over the MCM diameter (175–250 μm) and porosity (58–76%) allows the extracellular matrix structure to be tailored to different tissue engineering applications. The wall structures within MCMs share similarities with the highly compacted and recapitulated collagen porosity in native tissues. This approach in the future can be used to 3D print more complicated biomimetic structures that require cell positioning during printing.
- 22 April 2020
- Published by Springer Nature in Biomedical Microdevices
- Vol. 22 (2) , 1-18
Detection of renal biomarkers in chronic kidney disease using microfluidics: progress, challenges and opportunities
Chronic kidney disease (CKD) typically evolves over many years in a latent period without clinical signs, posing key challenges to detection at relatively early stages of the disease. Accurate and timely diagnosis of CKD enable effective management of the disease and may prevent further progression. However, long turn-around times of current testing methods combined with their relatively high cost due to the need for established laboratory infrastructure, specialized instrumentation and trained personnel are drawbacks for efficient assessment and monitoring of CKD, especially in underserved and resource-poor locations. Among the emerging clinical laboratory approaches, microfluidic technology has gained increasing attention over the last two decades due to the possibility of miniaturizing bioanalytical assays and instrumentation, thus potentially improving diagnostic performance. In this article, we review current developments related to the detection of CKD biomarkers using microfluidics. A general trend in this emerging area is the search for novel, sensitive biomarkers for early detection of CKD using technology that is improved by means of microfluidics. It is anticipated that these innovative approaches will be soon adopted and utilized in both clinical and point-of-care settings, leading to improvements in life quality of patients.
- 22 April 2020
- Published by Springer Nature in Biomedical Microdevices
- Vol. 22 (2) , 1-18
Detection of renal biomarkers in chronic kidney disease using microfluidics: progress, challenges and opportunities
Chronic kidney disease (CKD) typically evolves over many years in a latent period without clinical signs, posing key challenges to detection at relatively early stages of the disease. Accurate and timely diagnosis of CKD enable effective management of the disease and may prevent further progression. However, long turn-around times of current testing methods combined with their relatively high cost due to the need for established laboratory infrastructure, specialized instrumentation and trained personnel are drawbacks for efficient assessment and monitoring of CKD, especially in underserved and resource-poor locations. Among the emerging clinical laboratory approaches, microfluidic technology has gained increasing attention over the last two decades due to the possibility of miniaturizing bioanalytical assays and instrumentation, thus potentially improving diagnostic performance. In this article, we review current developments related to the detection of CKD biomarkers using microfluidics. A general trend in this emerging area is the search for novel, sensitive biomarkers for early detection of CKD using technology that is improved by means of microfluidics. It is anticipated that these innovative approaches will be soon adopted and utilized in both clinical and point-of-care settings, leading to improvements in life quality of patients.