Yi Cui
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Yi Cui has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Beatriz Vidondo
Veterinary Public Health Institute, Vetsuisse Faculty, University of Bern, 3012 Bern, Switzerland
1 shared publication - Jennifer Stéphanie Eiermann
Division of Small Animal Internal Medicine, Department of Clinical Veterinary Medicine, Vetsuisse-Faculty, University of Bern, 3012 Bern, Switzerland
1 shared publication - Katarina Hazuchova
Clinic for Small Animals (Internal Medicine, Clinical Pathology and Clinical Pathophysiology), Justus-Liebig-University, 35392 Giessen, Germany
1 shared publication - Miguel Campos
AniCura Medisch Centrum Voor Dieren, Isolatorweg 45, 1014 AS Amsterdam, The Netherlands
1 shared publication - Simone Schuller
Small Animal Clinic, Department of Clinical Veterinary Medicine, Vetsuisse Faculty, University of Bern
1 shared publication
Latest Publications
- Open Access
Comparison between a Flash Glucose Monitoring System and a Portable Blood Glucose Meter for Monitoring of Cats with Diabetic Ketosis or Ketoacidosis
Cats with diabetic ketosis or ketoacidosis DK(A) require intensive glucose monitoring. The aim of this study was to assess the agreement between a portable blood glucose meter (PBGM) and a flash glucose monitoring system (FGMS; FreeStyle Libre 2.0 Abbott®) measuring interstitial glucose in cats with DK(A). Ten client-owned cats with naturally occurring DK(A) were prospectively enrolled. Glucose concentrations were assessed with both methods every 1–3 h until resolution of DK(A), and every 4–8 h thereafter. While the median FGMS measured glucose concentration (14.3 mmol/L) was significantly lower than the median PBGM measured glucose concentration (19 mmol/L) (p < 0.001), the overall correlation between the FGMS and PBGM was high (r = 0.88; p < 0.001). In the Parkes error grid analysis, 98.3% of measurements fell in zones A and B. Bland–Altman plot analysis demonstrated that in the low glycaemic range (BG < 5.5 mmol/L), 50% of FGMS measurements deviated more than ±0.83 mmol/L, and in the high glycaemic range (BG > 5.5 mmol/L), 81% of results deviated >15% from the PBGM measurements. There was significant inter-individual variation in the difference between glucose concentrations measured by the FGMS and PBGM (p < 0.001). In spite of being more easily tolerated and easier to use, currently this method cannot be recommended for routine monitoring of cats with DK(A).
Open AccessComparison between a Flash Glucose Monitoring System and a Portable Blood Glucose Meter for Monitoring of Cats with Diabetic Ketosis or Ketoacidosis
Cats with diabetic ketosis or ketoacidosis DK(A) require intensive glucose monitoring. The aim of this study was to assess the agreement between a portable blood glucose meter (PBGM) and a flash glucose monitoring system (FGMS; FreeStyle Libre 2.0 Abbott®) measuring interstitial glucose in cats with DK(A). Ten client-owned cats with naturally occurring DK(A) were prospectively enrolled. Glucose concentrations were assessed with both methods every 1–3 h until resolution of DK(A), and every 4–8 h thereafter. While the median FGMS measured glucose concentration (14.3 mmol/L) was significantly lower than the median PBGM measured glucose concentration (19 mmol/L) (p < 0.001), the overall correlation between the FGMS and PBGM was high (r = 0.88; p < 0.001). In the Parkes error grid analysis, 98.3% of measurements fell in zones A and B. Bland–Altman plot analysis demonstrated that in the low glycaemic range (BG < 5.5 mmol/L), 50% of FGMS measurements deviated more than ±0.83 mmol/L, and in the high glycaemic range (BG > 5.5 mmol/L), 81% of results deviated >15% from the PBGM measurements. There was significant inter-individual variation in the difference between glucose concentrations measured by the FGMS and PBGM (p < 0.001). In spite of being more easily tolerated and easier to use, currently this method cannot be recommended for routine monitoring of cats with DK(A).