Adam Abdul Hakeem Baidoo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Adam Abdul Hakeem Baidoo has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Liangzhi Xie
Beijing Engineering Research Center of Protein and Antibody, Sinocelltech Ltd., Beijing 100176, China
4 shared publications - Cuige Gao
Beijing Engineering Research Center of Protein and Antibody, Sinocelltech Ltd., Beijing 100176, China
2 shared publications - Dongfang Liu
Beijing Engineering Research Center of Protein and Antibody, Sinocelltech Ltd., No. 31 Kechuang 7th Street, BDA, Beijing 100176, China
2 shared publications - Huo Su
Beijing Engineering Research Center of Protein and Antibody, Sinocelltech Ltd., Beijing 100176, China
2 shared publications - Jian Li
Beijing Engineering Research Center of Protein and Antibody, Sinocelltech Ltd., No. 31 Kechuang 7th Street, BDA, Beijing 100176, China
2 shared publications - Jiang Yi
Beijing Engineering Research Center of Protein and Antibody, Sinocelltech Ltd., No. 31 Kechuang 7th Street, BDA, Beijing 100176, China
2 shared publications
Latest Publications
- Open Access
Baseline Anti-SARS-CoV-2 IgG and Protection from Symptomatic Infection: Post Hoc Analysis of the SCTV01E Phase 3 Randomized Trial
Background: Following SARS-CoV-2 infection, the necessity of vaccination after natural infection remains uncertain. However, many asymptomatic individuals who test negative virologically may nevertheless receive vaccination without being aware of their prior infection. Investigating the implications for vaccine safety and efficacy is crucial. Methods: We analyzed the daily fluctuations in anti-SARS-CoV-2 IgG antibody levels during the enrollment period of a phase 3 randomized, double-blinded, placebo-controlled clinical trial of a tetravalent COVID-19 protein vaccine, SCTV01E. Additionally, we investigated the relationship between baseline IgG levels and their protection against COVID-19 in participants who received placebo. Results: The daily enrolled participants with different baseline IgG levels (1000 BAU/mL) showed dynamic changes with the enrollment date. Among participants with baseline IgG levels < 338 BAU/mL, vaccination conferred a relative protective efficacy of 69.15% (95% CI: 51.14–80.52%) against symptomatic SARS-CoV-2 infection compared with the control group. Conversely, in those with higher baseline IgG levels (≥338 BAU/mL), vaccination did not confer additional benefit. In the placebo group, the relative protection in participants with baseline IgG levels ≥ 338 BAU/mL was 93.79% (87.60%, 96.89%) compared to that of those with baseline IgG levels < 338 BAU/mL. The safety profile of SCTV01E in participants with baseline IgG ≥ 338 BAU/mL was comparable to that in participants with <338 BAU/mL, with favorable safety profiles. Conclusions: During the SCTV01E phase 3 clinical trial, an anti-SARS-CoV-2 IgG antibody IgG level of 338 BAU/mL was suitable for screening individuals in the early phase post-infection alongside virological tests. Vaccinating the infected population was safe and did not compromise efficacy. Clinical Trial: NCT05308576.
Open AccessBaseline Anti-SARS-CoV-2 IgG and Protection from Symptomatic Infection: Post Hoc Analysis of the SCTV01E Phase 3 Randomized Trial
Background: Following SARS-CoV-2 infection, the necessity of vaccination after natural infection remains uncertain. However, many asymptomatic individuals who test negative virologically may nevertheless receive vaccination without being aware of their prior infection. Investigating the implications for vaccine safety and efficacy is crucial. Methods: We analyzed the daily fluctuations in anti-SARS-CoV-2 IgG antibody levels during the enrollment period of a phase 3 randomized, double-blinded, placebo-controlled clinical trial of a tetravalent COVID-19 protein vaccine, SCTV01E. Additionally, we investigated the relationship between baseline IgG levels and their protection against COVID-19 in participants who received placebo. Results: The daily enrolled participants with different baseline IgG levels (1000 BAU/mL) showed dynamic changes with the enrollment date. Among participants with baseline IgG levels < 338 BAU/mL, vaccination conferred a relative protective efficacy of 69.15% (95% CI: 51.14–80.52%) against symptomatic SARS-CoV-2 infection compared with the control group. Conversely, in those with higher baseline IgG levels (≥338 BAU/mL), vaccination did not confer additional benefit. In the placebo group, the relative protection in participants with baseline IgG levels ≥ 338 BAU/mL was 93.79% (87.60%, 96.89%) compared to that of those with baseline IgG levels < 338 BAU/mL. The safety profile of SCTV01E in participants with baseline IgG ≥ 338 BAU/mL was comparable to that in participants with <338 BAU/mL, with favorable safety profiles. Conclusions: During the SCTV01E phase 3 clinical trial, an anti-SARS-CoV-2 IgG antibody IgG level of 338 BAU/mL was suitable for screening individuals in the early phase post-infection alongside virological tests. Vaccinating the infected population was safe and did not compromise efficacy. Clinical Trial: NCT05308576.
- Open Access
- 12 May 2025
- Published by MDPI AG in Preprints.org
Comparative Statistical Analysis between Neutralization Assays in Vaccine Immunogenicity Assessments
SARS-CoV-2 led to the swift development of vaccines, and neutralization assays played a crucial role in assessing their effectiveness. A post-hoc analysis of a Phase I/II trial evaluated the immunogenicity of a bivalent SARS-CoV-2 protein vaccine. We assessed vaccine immunogenicity using live virus neutralization assays (LVNA) and pseudotyped virus neutralization assays (PVNA) to measure antibody responses against different variants, including Alpha, Beta, and Delta. Various statistical techniques, including correlation coefficients, regression models, and Bland–Altman plots, were employed to assess the relationship between antibody titers from the two assays. The study analyzed 324 samples for Alpha and Beta variants and 505 for Delta. PVNA demonstrated over 90% sensitivity and specificity for LVNA across all variants, with accuracy rates of 98.8% for Alpha, 99.1% for Beta, and 94.3% for Delta. The Pearson correlation between PVNA and LVNA was strong for Alpha (r = 0.9614), Beta (r = 0.9517), and Delta (r = 0.9072). Bland-Altman plots and Kernel density plots indicated good agreement between PVNA and LVNA. PVNA and LVNA showed a strong correlation, suggesting that PVNA is a reliable alternative to LVNA for assessing vaccine effectiveness. PVNA's high sensitivity and specificity make it valuable for monitoring immune responses.
- 12 May 2025
- Published by MDPI AG in Preprints.org
Open AccessComparative Statistical Analysis between Neutralization Assays in Vaccine Immunogenicity Assessments
SARS-CoV-2 led to the swift development of vaccines, and neutralization assays played a crucial role in assessing their effectiveness. A post-hoc analysis of a Phase I/II trial evaluated the immunogenicity of a bivalent SARS-CoV-2 protein vaccine. We assessed vaccine immunogenicity using live virus neutralization assays (LVNA) and pseudotyped virus neutralization assays (PVNA) to measure antibody responses against different variants, including Alpha, Beta, and Delta. Various statistical techniques, including correlation coefficients, regression models, and Bland–Altman plots, were employed to assess the relationship between antibody titers from the two assays. The study analyzed 324 samples for Alpha and Beta variants and 505 for Delta. PVNA demonstrated over 90% sensitivity and specificity for LVNA across all variants, with accuracy rates of 98.8% for Alpha, 99.1% for Beta, and 94.3% for Delta. The Pearson correlation between PVNA and LVNA was strong for Alpha (r = 0.9614), Beta (r = 0.9517), and Delta (r = 0.9072). Bland-Altman plots and Kernel density plots indicated good agreement between PVNA and LVNA. PVNA and LVNA showed a strong correlation, suggesting that PVNA is a reliable alternative to LVNA for assessing vaccine effectiveness. PVNA's high sensitivity and specificity make it valuable for monitoring immune responses.
- Open Access
Fc-Modified Antibody in Hospitalized Severe COVID-19 Patients
Background: Hospitalized patients with severe COVID-19 are at high risk of clinical deterioration. Methods: A global, randomized, double-blinded, and placebo-controlled phase II trial that investigated the clinical efficacy of SCTA01, an Fc-modified monoclonal antibody, in patients hospitalized with severe COVID-19 during the Delta variant wave was performed. The primary outcome was time to clinical improvement up to Day 29. Secondary outcomes measured the all-cause mortality rate up to Day 29, time to SARS-CoV-2 RNA negativity up to Day 29, and the number of antibody-dependent enhancements. Results: From 27 March 2021, to 11 February 2022, 102 hospitalized adults with severe COVID-19 received a single intravenous infusion of SCTA01 15 mg/kg or 50 mg/kg or placebo in a 1:1:1 ratio. The median time to clinical improvement in the SCTA01 group was numerically shorter than that in the placebo group; however, the between group difference was statistically non-significant (SCTA01 15 mg/kg vs. placebo, HR 0.99, 95% CI 0.55–1.77, p = 0.742; SCTA01 50 mg/kg vs. placebo, HR 1.07, 95% CI 0.61–1.88, p = 0.095). The median time to achieve a negative SARS-CoV-2 status was shorter in the SCTA01 15 mg/kg group (14.0 days vs. 27.0 days) but not in the SCTA01 50 mg/kg group (28.0 days vs. 27.0 days) compared to the placebo group. Adverse events were comparable across all groups, and no treatment-related serious adverse event or antibody-dependent enhancement was reported. Conclusions: The Fc-modified antibody was safe but lacked significant clinical efficacy in vivo, likely due to the SARS-CoV-2 viral mutation.
Open AccessFc-Modified Antibody in Hospitalized Severe COVID-19 Patients
Background: Hospitalized patients with severe COVID-19 are at high risk of clinical deterioration. Methods: A global, randomized, double-blinded, and placebo-controlled phase II trial that investigated the clinical efficacy of SCTA01, an Fc-modified monoclonal antibody, in patients hospitalized with severe COVID-19 during the Delta variant wave was performed. The primary outcome was time to clinical improvement up to Day 29. Secondary outcomes measured the all-cause mortality rate up to Day 29, time to SARS-CoV-2 RNA negativity up to Day 29, and the number of antibody-dependent enhancements. Results: From 27 March 2021, to 11 February 2022, 102 hospitalized adults with severe COVID-19 received a single intravenous infusion of SCTA01 15 mg/kg or 50 mg/kg or placebo in a 1:1:1 ratio. The median time to clinical improvement in the SCTA01 group was numerically shorter than that in the placebo group; however, the between group difference was statistically non-significant (SCTA01 15 mg/kg vs. placebo, HR 0.99, 95% CI 0.55–1.77, p = 0.742; SCTA01 50 mg/kg vs. placebo, HR 1.07, 95% CI 0.61–1.88, p = 0.095). The median time to achieve a negative SARS-CoV-2 status was shorter in the SCTA01 15 mg/kg group (14.0 days vs. 27.0 days) but not in the SCTA01 50 mg/kg group (28.0 days vs. 27.0 days) compared to the placebo group. Adverse events were comparable across all groups, and no treatment-related serious adverse event or antibody-dependent enhancement was reported. Conclusions: The Fc-modified antibody was safe but lacked significant clinical efficacy in vivo, likely due to the SARS-CoV-2 viral mutation.
- Open Access
Immunogenicity and Safety of Omicron-Containing Multivalent COVID-19 Vaccines in Unvaccinated and Previously Vaccinated Adults
The SARS-CoV-2 evolution trajectory remains uncertain, and the antigenic characteristics of future variants are highly unpredictable. We report the immunogenicity and safety of multivalent COVID-19 vaccines, SCTV01E and SCTV01E-1, against Omicron BA.5. This phase 2 trial randomized 400 adults into two cohorts, 160 unvaccinated (3 doses) and 240 previously vaccinated (2 doses) individuals to receive 30 µg SCTV01E-1 or 30 µg SCTV01E (1:1) between 4 November and 28 November 2022. Among the unvaccinated cohort, day 42 geometric mean fold rises (GMFRs) of neutralizing antibodies (nAb) against Omicron BA.5 were reported to be 12.8× and 20.5× over day 0 for SCTV01E-1 and SCTV01E, respectively. On day 178, both vaccines increased geometric mean titers (GMTs) of nAb against BA.5 following the booster dose compared to pre-booster levels on D150. Similar frequencies of solicited [6.2% (5/81) and 7.6% (6/79)] and unsolicited [11.1% (9/81) and 10.1% (8/79)] adverse events (AEs) were reported in SCTV01E-1 and SCTV01E groups, respectively. Grade 3 or more AEs were < 2% in both vaccine groups [SCTV01E-1: 1.2% (1/81), SCTV01E: 1.3% (1/79)]. In the previously vaccinated cohort, similar GMFRs were reported on day 28 (SCTV01E-1: 9.4× and SCTV01E: 8.7×) over baseline (D0). On day 148, both vaccines showed increased nAb levels with similar GMFRs over D120. Comparable incidences of solicited [13.2% (16/121) and 10.9% (13/119)] and unsolicited [17.4% (21/121) and 10.9% (13/119)] AEs were reported in SCTV01E-1 and SCTV01E groups, respectively. Numerically identical ≥ grade 3 AEs [SCTV01E-1: 1.7% (2/121) and SCTV01E: 1.7% (2/119)] were reported. This trial demonstrates the effectiveness of updated multivalent vaccines with acceptable safety profiles.
Open AccessImmunogenicity and Safety of Omicron-Containing Multivalent COVID-19 Vaccines in Unvaccinated and Previously Vaccinated Adults
The SARS-CoV-2 evolution trajectory remains uncertain, and the antigenic characteristics of future variants are highly unpredictable. We report the immunogenicity and safety of multivalent COVID-19 vaccines, SCTV01E and SCTV01E-1, against Omicron BA.5. This phase 2 trial randomized 400 adults into two cohorts, 160 unvaccinated (3 doses) and 240 previously vaccinated (2 doses) individuals to receive 30 µg SCTV01E-1 or 30 µg SCTV01E (1:1) between 4 November and 28 November 2022. Among the unvaccinated cohort, day 42 geometric mean fold rises (GMFRs) of neutralizing antibodies (nAb) against Omicron BA.5 were reported to be 12.8× and 20.5× over day 0 for SCTV01E-1 and SCTV01E, respectively. On day 178, both vaccines increased geometric mean titers (GMTs) of nAb against BA.5 following the booster dose compared to pre-booster levels on D150. Similar frequencies of solicited [6.2% (5/81) and 7.6% (6/79)] and unsolicited [11.1% (9/81) and 10.1% (8/79)] adverse events (AEs) were reported in SCTV01E-1 and SCTV01E groups, respectively. Grade 3 or more AEs were < 2% in both vaccine groups [SCTV01E-1: 1.2% (1/81), SCTV01E: 1.3% (1/79)]. In the previously vaccinated cohort, similar GMFRs were reported on day 28 (SCTV01E-1: 9.4× and SCTV01E: 8.7×) over baseline (D0). On day 148, both vaccines showed increased nAb levels with similar GMFRs over D120. Comparable incidences of solicited [13.2% (16/121) and 10.9% (13/119)] and unsolicited [17.4% (21/121) and 10.9% (13/119)] AEs were reported in SCTV01E-1 and SCTV01E groups, respectively. Numerically identical ≥ grade 3 AEs [SCTV01E-1: 1.7% (2/121) and SCTV01E: 1.7% (2/119)] were reported. This trial demonstrates the effectiveness of updated multivalent vaccines with acceptable safety profiles.