Qi Feng Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Qi Feng Xu has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Chuan Lin
College of Mechanical, Electrical and Information Engineering, Putian University, Putian, China
2 shared publications - Dechan Lu
School of Intelligent Manufacturing, Putian University, Putian 351100, China
1 shared publication - Haihe Xie
School of Mechanical, Electrical & Information Engineering, Putian University, Putian, China
1 shared publication Yi Fan Huang
School of Electrical Engineering and Automation Fuzhou University Fuzhou China
1 shared publication- Yifan Huang
College of Electrical Engineering and Automation, Fuzhou University, Fuzhou, China
1 shared publication Zhehao Su
School of Mechanical, Electrical & Information Engineering, Putian University, Putian, China
1 shared publication
Latest Publications
- 17 July 2024
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 416 (23) , 5089-5096
Artificial intelligence-based plasma exosome label-free SERS profiling strategy for early lung cancer detection
As a lung cancer biomarker, exosomes were utilized for in vitro diagnosis to overcome the lack of sensitivity of conventional imaging and the potential harm caused by tissue biopsy. However, given the inherent heterogeneity of exosomes, the challenge of accurately and reliably recognizing subtle differences in the composition of exosomes from clinical samples remains significant. Herein, we report an artificial intelligence-assisted surface-enhanced Raman spectroscopy (SERS) strategy for label-free profiling of plasma exosomes for accurate diagnosis of early-stage lung cancer. Specifically, we build a deep learning model using exosome spectral data from lung cancer cell lines and normal cell lines. Then, we extracted the features of cellular exosomes by training a convolutional neural network (CNN) model on the spectral data of cellular exosomes and used them as inputs to a support vector machine (SVM) model. Eventually, the spectral features of plasma exosomes were combined to effectively distinguish adenocarcinoma in situ (AIS) from healthy controls (HC). Notably, the approach demonstrated significant performance in distinguishing AIS from HC samples, with an area under the curve (AUC) of 0.84, sensitivity of 83.3%, and specificity of 83.3%. Together, the results demonstrate the utility of exosomes as a biomarker for the early diagnosis of lung cancer and provide a new approach to prescreening techniques for lung cancer.
- 17 July 2024
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 416 (23) , 5089-5096
Artificial intelligence-based plasma exosome label-free SERS profiling strategy for early lung cancer detection
As a lung cancer biomarker, exosomes were utilized for in vitro diagnosis to overcome the lack of sensitivity of conventional imaging and the potential harm caused by tissue biopsy. However, given the inherent heterogeneity of exosomes, the challenge of accurately and reliably recognizing subtle differences in the composition of exosomes from clinical samples remains significant. Herein, we report an artificial intelligence-assisted surface-enhanced Raman spectroscopy (SERS) strategy for label-free profiling of plasma exosomes for accurate diagnosis of early-stage lung cancer. Specifically, we build a deep learning model using exosome spectral data from lung cancer cell lines and normal cell lines. Then, we extracted the features of cellular exosomes by training a convolutional neural network (CNN) model on the spectral data of cellular exosomes and used them as inputs to a support vector machine (SVM) model. Eventually, the spectral features of plasma exosomes were combined to effectively distinguish adenocarcinoma in situ (AIS) from healthy controls (HC). Notably, the approach demonstrated significant performance in distinguishing AIS from HC samples, with an area under the curve (AUC) of 0.84, sensitivity of 83.3%, and specificity of 83.3%. Together, the results demonstrate the utility of exosomes as a biomarker for the early diagnosis of lung cancer and provide a new approach to prescreening techniques for lung cancer.
- 1 February 2022
- Published by Wiley in Quality and Reliability Engineering International
- Vol. 38 (5) , 2372-2387
An HFM‐CREAM model for the assessment of human reliability and quantification
Human reliability analysis (HRA) is a proactive approach to model and evaluate systematic human errors and has been extensively implemented in various complicated systems. The assessment of human errors relies heavily on the knowledge and experience of experts in real‐world cases. Moreover, there are usually specific sorts of uncertainty while experts use linguistic labels to evaluate human failure events. In this context, this paper seeks to establish a new model based on the hesitant fuzzy matrix (HFM) and the cognitive reliability and error analysis method (CREAM) to conduct a quantitative analysis of human errors. This model handles the multiple crisp scores of the common performance conditions (CPCs) given by experts according to the context description in terms of CPCs, determines the weights of CPCs by the HFM, and elicits the human error probability (HEP) point estimation formula considering consequences based on the CREAM. Finally, the effectiveness and practicality of the presented HFM‐CREAM model are demonstrated through the emergency response analysis of the steam generator tube rupture (SGTR) in nuclear power plant.
- 1 February 2022
- Published by Wiley in Quality and Reliability Engineering International
- Vol. 38 (5) , 2372-2387
An HFM‐CREAM model for the assessment of human reliability and quantification
Human reliability analysis (HRA) is a proactive approach to model and evaluate systematic human errors and has been extensively implemented in various complicated systems. The assessment of human errors relies heavily on the knowledge and experience of experts in real‐world cases. Moreover, there are usually specific sorts of uncertainty while experts use linguistic labels to evaluate human failure events. In this context, this paper seeks to establish a new model based on the hesitant fuzzy matrix (HFM) and the cognitive reliability and error analysis method (CREAM) to conduct a quantitative analysis of human errors. This model handles the multiple crisp scores of the common performance conditions (CPCs) given by experts according to the context description in terms of CPCs, determines the weights of CPCs by the HFM, and elicits the human error probability (HEP) point estimation formula considering consequences based on the CREAM. Finally, the effectiveness and practicality of the presented HFM‐CREAM model are demonstrated through the emergency response analysis of the steam generator tube rupture (SGTR) in nuclear power plant.
- Open Access
- 27 September 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (19) , 9008
Applications of FFTA–HFACS for Analyzing Human and Organization Factors in Electric Misoperation Accidents
Human and organizational factors (HOFs) play an important role in electric misoperation accidents (EMAs), but research into the reliability of human factors is still in its infancy in the field of EMAs, and further investment in research is urgently required. To analyze the HOFs in EMAs, a hybrid method including the Human Factors Analysis and Classification System (HFACS) and fuzzy fault tree analysis (FFTA) was applied to EMAs for the first time in the paper. HFACS is used to identify and classify the HOFs with 135 accidents, reorganized as basic events (BEs), intermediate events (IEs), and top event (TE), and develop the architecture of fault tree (FT). Fuzzy aggregation is employed to address experts’ expressions and obtain the failure probabilities of the BEs and the minimal cut sets (MCSs) of the FT. The approach generates BEs failure probabilities without reliance on quantitative historical failure statistics of EMAs via qualitative records processing. The FFTA–HFACS model is applied for quantitative analysis of the probability of failure of electrical mishaps and the interaction between accident risk factors. It can assist professionals in deciding whether and where to take preventive or corrective actions and assist in knowledgeable decision-making around the electric operation and maintenance process. Finally, applying this hybrid method to EMAs, the results show that the probability of an EMAs is 1.0410 × 10−2, which is a risk level that is likely to occur and must be controlled. Two of the most important risk factors are habitual violations and supervisory violation; a combination of risk factors of inadequate work preparation and paralysis, and irresponsibility on the part of employees are also frequent errors.
- 27 September 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (19) , 9008
Open AccessApplications of FFTA–HFACS for Analyzing Human and Organization Factors in Electric Misoperation Accidents
Human and organizational factors (HOFs) play an important role in electric misoperation accidents (EMAs), but research into the reliability of human factors is still in its infancy in the field of EMAs, and further investment in research is urgently required. To analyze the HOFs in EMAs, a hybrid method including the Human Factors Analysis and Classification System (HFACS) and fuzzy fault tree analysis (FFTA) was applied to EMAs for the first time in the paper. HFACS is used to identify and classify the HOFs with 135 accidents, reorganized as basic events (BEs), intermediate events (IEs), and top event (TE), and develop the architecture of fault tree (FT). Fuzzy aggregation is employed to address experts’ expressions and obtain the failure probabilities of the BEs and the minimal cut sets (MCSs) of the FT. The approach generates BEs failure probabilities without reliance on quantitative historical failure statistics of EMAs via qualitative records processing. The FFTA–HFACS model is applied for quantitative analysis of the probability of failure of electrical mishaps and the interaction between accident risk factors. It can assist professionals in deciding whether and where to take preventive or corrective actions and assist in knowledgeable decision-making around the electric operation and maintenance process. Finally, applying this hybrid method to EMAs, the results show that the probability of an EMAs is 1.0410 × 10−2, which is a risk level that is likely to occur and must be controlled. Two of the most important risk factors are habitual violations and supervisory violation; a combination of risk factors of inadequate work preparation and paralysis, and irresponsibility on the part of employees are also frequent errors.