Zhen Tian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Zhen Tian has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Mingguang He
School of Optometry, The Hong Kong Polytechnic University, Hong Kong SAR, China
3 shared publications - Fan Song
School of Optometry, Hong Kong Polytechnic University, Hong Kong, China (Hong Kong)
2 shared publications - Guangyu Li
Guangdong Institute of Intelligence Science and Technology, Zhuhai, China
2 shared publications - Jian Zhang
State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, Guangdong, China
2 shared publications - Mengying Lai
School of Optometry, Hong Kong Polytechnic University, Hong Kong, China (Hong Kong)
2 shared publications - Mingge Li
Department of Ophthalmology, Shenzhen Nanshan People's Hospital, Shenzhen, Guangdong, China
2 shared publications
Latest Publications
- Open Access
- 9 November 2026
- Published by Association for Computing Machinery (ACM)
- p. 9657-9666
SelfieAvatar: High-Fidelity Animatable 3D Head Avatars from In-the-Wild Selfies
- 9 November 2026
- Published by Association for Computing Machinery (ACM)
- p. 9657-9666
Open AccessSelfieAvatar: High-Fidelity Animatable 3D Head Avatars from In-the-Wild Selfies
- Open Access
- 28 April 2026
- Published by JMIR Publications Inc. in JMIR Human Factors
- Vol. 13 (1) , e84479
Identifying Biomarkers Using a Portable, Home-Based Eye-Tracking System to Predict Short-Term Visual Fatigue Deterioration: Prospective Observational Feasibility Study
Background: The escalating prevalence of screen-related eye fatigue has become a health burden in the digital era worldwide, yet routine monitoring relies largely on subjective reports. This underscores the urgent need for clinically applicable, objective diagnostic solutions. Ocular metrics provide an objective method to assess computer vision syndrome, or asthenopia. Objective: This study aimed to develop and evaluate an integrated at-home system for predicting short-term deteriorated asthenopia using objective ocular metrics. This system classifies the short-term risk level for practical monitoring and automatically generates a session report that summarizes metrics to complement symptom-based evaluation. Methods: We developed EyeFatigue Tracker, an integrated at-home system delivered via a desktop app, comprising a head-mounted device to record binocular infrared eye videos, a deep learning (DL) model to extract ocular metrics, and a machine learning (ML) classifier to estimate asthenopia risk. The DL model, trained on an in-house dataset, segments the palpebral fissure, pupil, and iris from recorded videos to derive ocular metrics. To build the prediction model, participants were recruited to complete a 1-hour computer gameplay session. Changes in the Computer Vision Syndrome Questionnaire (CVS-Q) scores served as the primary outcome measure to classify participants into deteriorated and nondeteriorated asthenopia groups. Metrics showing significant between-group differences were used as inputs for four ML models, including support vector machine (SVM), decision tree, extreme gradient boosting (XGBoost), and random forest, to identify deteriorated asthenopia. Model performance was evaluated with fivefold cross-validation. Results: This study enrolled 38 participants aged 19-31 (mean 24.8, SD 3.11) years. Following visual tasks, participants’ CVS-Q scores were higher compared to baseline values (mean 9.21, SD 4.57, vs mean 6.76, SD 3.76; P<.001). Alongside the critical flicker fusion frequency (CFF), nine key features were selected as predictive indicators, with the top five reflecting fissure length variability (variance, coefficient of variation, and SD), average blink duration, and pupil size variability (coefficient of variation). Most ML models exhibited high discriminative ability, with the random forest achieving the best overall performance (mean accuracy 0.720, SD 0.035; mean area under the receiver operating characteristic curve 0.850, 95% CI 0.830-0.860). Conclusions: The findings highlight the potential of objective indicators in identifying individuals at risk for asthenopia following computer gameplay. The ML models using ocular biomarkers identified in this study achieved plausible discriminative ability in detecting deteriorated asthenopia. EyeFatigue Tracker functions as an integrated, at-home system that produces a risk level prediction and a concise session report, supporting early detection and informing preventive care in real-world settings.
- 28 April 2026
- Published by JMIR Publications Inc. in JMIR Human Factors
- Vol. 13 (1) , e84479
Open AccessIdentifying Biomarkers Using a Portable, Home-Based Eye-Tracking System to Predict Short-Term Visual Fatigue Deterioration: Prospective Observational Feasibility Study
Background: The escalating prevalence of screen-related eye fatigue has become a health burden in the digital era worldwide, yet routine monitoring relies largely on subjective reports. This underscores the urgent need for clinically applicable, objective diagnostic solutions. Ocular metrics provide an objective method to assess computer vision syndrome, or asthenopia. Objective: This study aimed to develop and evaluate an integrated at-home system for predicting short-term deteriorated asthenopia using objective ocular metrics. This system classifies the short-term risk level for practical monitoring and automatically generates a session report that summarizes metrics to complement symptom-based evaluation. Methods: We developed EyeFatigue Tracker, an integrated at-home system delivered via a desktop app, comprising a head-mounted device to record binocular infrared eye videos, a deep learning (DL) model to extract ocular metrics, and a machine learning (ML) classifier to estimate asthenopia risk. The DL model, trained on an in-house dataset, segments the palpebral fissure, pupil, and iris from recorded videos to derive ocular metrics. To build the prediction model, participants were recruited to complete a 1-hour computer gameplay session. Changes in the Computer Vision Syndrome Questionnaire (CVS-Q) scores served as the primary outcome measure to classify participants into deteriorated and nondeteriorated asthenopia groups. Metrics showing significant between-group differences were used as inputs for four ML models, including support vector machine (SVM), decision tree, extreme gradient boosting (XGBoost), and random forest, to identify deteriorated asthenopia. Model performance was evaluated with fivefold cross-validation. Results: This study enrolled 38 participants aged 19-31 (mean 24.8, SD 3.11) years. Following visual tasks, participants’ CVS-Q scores were higher compared to baseline values (mean 9.21, SD 4.57, vs mean 6.76, SD 3.76; P<.001). Alongside the critical flicker fusion frequency (CFF), nine key features were selected as predictive indicators, with the top five reflecting fissure length variability (variance, coefficient of variation, and SD), average blink duration, and pupil size variability (coefficient of variation). Most ML models exhibited high discriminative ability, with the random forest achieving the best overall performance (mean accuracy 0.720, SD 0.035; mean area under the receiver operating characteristic curve 0.850, 95% CI 0.830-0.860). Conclusions: The findings highlight the potential of objective indicators in identifying individuals at risk for asthenopia following computer gameplay. The ML models using ocular biomarkers identified in this study achieved plausible discriminative ability in detecting deteriorated asthenopia. EyeFatigue Tracker functions as an integrated, at-home system that produces a risk level prediction and a concise session report, supporting early detection and informing preventive care in real-world settings.
- Open Access
- 20 September 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Identifying Biomarkers Using a Portable, Home-Based Eye-Tracking System to Predict Short-Term Visual Fatigue Deterioration: Prospective Observational Feasibility Study (Preprint)
BACKGROUND The escalating prevalence of screen-related eye fatigue has become a health burden in the digital era worldwide, yet routine monitoring relies largely on subjective reports. This underscores the urgent need for clinically applicable, objective diagnostic solutions. Ocular metrics provide an objective method to assess computer vision syndrome, or asthenopia. OBJECTIVE This study aimed to develop and evaluate an integrated at-home system for predicting short-term deteriorated asthenopia using objective ocular metrics. This system classifies the short-term risk level for practical monitoring and automatically generates a session report that summarizes metrics to complement symptom-based evaluation. METHODS We developed EyeFatigue Tracker, an integrated at-home system delivered via a desktop app, comprising a head-mounted device to record binocular infrared eye videos, a deep learning (DL) model to extract ocular metrics, and a machine learning (ML) classifier to estimate asthenopia risk. The DL model, trained on an in-house dataset, segments the palpebral fissure, pupil, and iris from recorded videos to derive ocular metrics. To build the prediction model, participants were recruited to complete a 1-hour computer gameplay session. Changes in the Computer Vision Syndrome Questionnaire (CVS-Q) scores served as the primary outcome measure to classify participants into deteriorated and nondeteriorated asthenopia groups. Metrics showing significant between-group differences were used as inputs for four ML models, including support vector machine (SVM), decision tree, extreme gradient boosting (XGBoost), and random forest, to identify deteriorated asthenopia. Model performance was evaluated with fivefold cross-validation. RESULTS This study enrolled 38 participants aged 19-31 (mean 24.8, SD 3.11) years. Following visual tasks, participants’ CVS-Q scores were higher compared to baseline values (mean 9.21, SD 4.57, vs mean 6.76, SD 3.76; P<.001). Alongside the critical flicker fusion frequency (CFF), nine key features were selected as predictive indicators, with the top five reflecting fissure length variability (variance, coefficient of variation, and SD), average blink duration, and pupil size variability (coefficient of variation). Most ML models exhibited high discriminative ability, with the random forest achieving the best overall performance (mean accuracy 0.720, SD 0.035; mean area under the receiver operating characteristic curve 0.850, 95% CI 0.830-0.860). CONCLUSIONS The findings highlight the potential of objective indicators in identifying individuals at risk for asthenopia following computer gameplay. The ML models using ocular biomarkers identified in this study achieved plausible discriminative ability in detecting deteriorated asthenopia. EyeFatigue Tracker functions as an integrated, at-home system that produces a risk level prediction and a concise session report, supporting early detection and informing preventive care in real-world settings.
- 20 September 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessIdentifying Biomarkers Using a Portable, Home-Based Eye-Tracking System to Predict Short-Term Visual Fatigue Deterioration: Prospective Observational Feasibility Study (Preprint)
BACKGROUND The escalating prevalence of screen-related eye fatigue has become a health burden in the digital era worldwide, yet routine monitoring relies largely on subjective reports. This underscores the urgent need for clinically applicable, objective diagnostic solutions. Ocular metrics provide an objective method to assess computer vision syndrome, or asthenopia. OBJECTIVE This study aimed to develop and evaluate an integrated at-home system for predicting short-term deteriorated asthenopia using objective ocular metrics. This system classifies the short-term risk level for practical monitoring and automatically generates a session report that summarizes metrics to complement symptom-based evaluation. METHODS We developed EyeFatigue Tracker, an integrated at-home system delivered via a desktop app, comprising a head-mounted device to record binocular infrared eye videos, a deep learning (DL) model to extract ocular metrics, and a machine learning (ML) classifier to estimate asthenopia risk. The DL model, trained on an in-house dataset, segments the palpebral fissure, pupil, and iris from recorded videos to derive ocular metrics. To build the prediction model, participants were recruited to complete a 1-hour computer gameplay session. Changes in the Computer Vision Syndrome Questionnaire (CVS-Q) scores served as the primary outcome measure to classify participants into deteriorated and nondeteriorated asthenopia groups. Metrics showing significant between-group differences were used as inputs for four ML models, including support vector machine (SVM), decision tree, extreme gradient boosting (XGBoost), and random forest, to identify deteriorated asthenopia. Model performance was evaluated with fivefold cross-validation. RESULTS This study enrolled 38 participants aged 19-31 (mean 24.8, SD 3.11) years. Following visual tasks, participants’ CVS-Q scores were higher compared to baseline values (mean 9.21, SD 4.57, vs mean 6.76, SD 3.76; P<.001). Alongside the critical flicker fusion frequency (CFF), nine key features were selected as predictive indicators, with the top five reflecting fissure length variability (variance, coefficient of variation, and SD), average blink duration, and pupil size variability (coefficient of variation). Most ML models exhibited high discriminative ability, with the random forest achieving the best overall performance (mean accuracy 0.720, SD 0.035; mean area under the receiver operating characteristic curve 0.850, 95% CI 0.830-0.860). CONCLUSIONS The findings highlight the potential of objective indicators in identifying individuals at risk for asthenopia following computer gameplay. The ML models using ocular biomarkers identified in this study achieved plausible discriminative ability in detecting deteriorated asthenopia. EyeFatigue Tracker functions as an integrated, at-home system that produces a risk level prediction and a concise session report, supporting early detection and informing preventive care in real-world settings.
- Open Access
- 25 September 2024
- Published by Wiley in Skin Research and Technology
- Vol. 30 (9) , e70076
Establishment of a Mouse Model for Porokeratosis Due to Mevalonate Diphosphate Decarboxylase Deficiency
Introduction: Porokeratosis (PK) is an autoinflammatory keratinization disease (AIKD) characterized by circular or annular skin lesions with a hyperkeratotic rim, pathologically shown as the cornoid lamella. Four genes that cause PK are associated with the mevalonate (MV) pathway. In Chinese PK patients, mevalonate diphosphate decarboxylase ( MVD ) is the most common causative gene. The lack of an animal model has greatly limited research on PK pathogenesis. Materials and Methods: In this research, we constructed K14‐CreER T2 ‐ Mvd fl/fl mice using the Cre‐LoxP system to create a mouse model for in‐depth studies of PK. The Epidermal Mvd gene was knocked out by intraperitoneal injection of Tamoxifen (TAM). Pathology, immunohistochemistry, RNA‐seq, and Western Blot analysis were performed. Results: Skin lesions appeared following Mvd deficiency, and pathological examination revealed the characteristic cornoid lamella, as well as cutaneous inflammation. Furthermore, we observed elevated levels of IL‐17A and IL‐1β, and a decreased Loricrin level in epidermal Mvd‐deficient mice. Compared with the wild‐type (WT) group, Mvd deficiency activated the expression of lipid metabolism‐related proteins. Conclusion: We developed the first mouse model for PK research, enabling further studies on disease development and treatment approaches.
- 25 September 2024
- Published by Wiley in Skin Research and Technology
- Vol. 30 (9) , e70076
Open AccessEstablishment of a Mouse Model for Porokeratosis Due to Mevalonate Diphosphate Decarboxylase Deficiency
Introduction: Porokeratosis (PK) is an autoinflammatory keratinization disease (AIKD) characterized by circular or annular skin lesions with a hyperkeratotic rim, pathologically shown as the cornoid lamella. Four genes that cause PK are associated with the mevalonate (MV) pathway. In Chinese PK patients, mevalonate diphosphate decarboxylase ( MVD ) is the most common causative gene. The lack of an animal model has greatly limited research on PK pathogenesis. Materials and Methods: In this research, we constructed K14‐CreER T2 ‐ Mvd fl/fl mice using the Cre‐LoxP system to create a mouse model for in‐depth studies of PK. The Epidermal Mvd gene was knocked out by intraperitoneal injection of Tamoxifen (TAM). Pathology, immunohistochemistry, RNA‐seq, and Western Blot analysis were performed. Results: Skin lesions appeared following Mvd deficiency, and pathological examination revealed the characteristic cornoid lamella, as well as cutaneous inflammation. Furthermore, we observed elevated levels of IL‐17A and IL‐1β, and a decreased Loricrin level in epidermal Mvd‐deficient mice. Compared with the wild‐type (WT) group, Mvd deficiency activated the expression of lipid metabolism‐related proteins. Conclusion: We developed the first mouse model for PK research, enabling further studies on disease development and treatment approaches.