Serena Concetta Rita Reina
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Serena Concetta Rita Reina has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Domenico Corso
CNR-IMM,Catania,Italy
5 shared publications - Giuseppe Andrea Screpis
University of Messina,Dept. ChiBioFarAm,Messina,Italy
5 shared publications - Giuseppe Emanuele Capuano
Consiglio Nazionale delle Ricerche Istituto per la Microelettronica e Microsistemi (CNR IMM),Catania,95121
5 shared publications - Maria Anna Coniglio
University of Catania,Dept. G.F. Ingrassia,Catania,Italy
5 shared publications - Roberta Farina
Consiglio Nazionale delle Ricerche Istituto per la Microelettronica e Microsistemi (CNR IMM),Catania,95121
5 shared publications - Sebania Libertino
Consiglio Nazionale delle Ricerche Istituto per la Microelettronica e Microsistemi (CNR IMM),Catania,95121
5 shared publications
Latest Publications
- 24 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 152-156
Labelling of Escherichia Coli Using a Porphyrin/CAPTISOL® Complex
The detection of bacterial pathogens is a critical objective in both environmental monitoring and clinical diagnostics. Bacterial detection commonly relies on culturing methods and biochemical assays or fluorescent labelling. This study evaluates the performance of a novel porphyrin-based fluorescent probe, H2T4/CAPTISOL@ (porphyrin/cyclodextrin), for real-time detection of Escherichia coli. Traditional fluorophores such as FITC (Fluorescein Isothiocyanate) and DAPI (4‘, 6-diamidino-2-phenylindole) suffer from photobleaching, pH sensitivity, and the need for fixation. In contrast, H2T4/CAPTISOL@ offers enhanced solubility, increased quantum yield, and selective membrane binding. In this work, we used a complex of porphyrins and CAPTISOL@ (H2T4/CAPTISOL@) as an innovative labelling agent. We aim to determine the optimal incubation time for H2T4/CAPTISOL ® to detect bacteria. Spectrofluorimetric and flow cytometric analyses revealed that 5 minutes of incubation yielded the highest fluorescence intensity and percentage of labeled bacteria. These findings confirm that H2T4/CAPTISOL@ enables efficient, fixation-free bacterial labeling in water samples, with optimal performance at short incubation times. This approach holds promise for rapid, in situ microbial monitoring in environmental and clinical settings.
- 24 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 152-156
Labelling of Escherichia Coli Using a Porphyrin/CAPTISOL® Complex
The detection of bacterial pathogens is a critical objective in both environmental monitoring and clinical diagnostics. Bacterial detection commonly relies on culturing methods and biochemical assays or fluorescent labelling. This study evaluates the performance of a novel porphyrin-based fluorescent probe, H2T4/CAPTISOL@ (porphyrin/cyclodextrin), for real-time detection of Escherichia coli. Traditional fluorophores such as FITC (Fluorescein Isothiocyanate) and DAPI (4‘, 6-diamidino-2-phenylindole) suffer from photobleaching, pH sensitivity, and the need for fixation. In contrast, H2T4/CAPTISOL@ offers enhanced solubility, increased quantum yield, and selective membrane binding. In this work, we used a complex of porphyrins and CAPTISOL@ (H2T4/CAPTISOL@) as an innovative labelling agent. We aim to determine the optimal incubation time for H2T4/CAPTISOL ® to detect bacteria. Spectrofluorimetric and flow cytometric analyses revealed that 5 minutes of incubation yielded the highest fluorescence intensity and percentage of labeled bacteria. These findings confirm that H2T4/CAPTISOL@ enables efficient, fixation-free bacterial labeling in water samples, with optimal performance at short incubation times. This approach holds promise for rapid, in situ microbial monitoring in environmental and clinical settings.
- 24 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 319-324
Development of a New System for Bacterial Load Detection in Water Samples Exploiting ATP Chemiluminescence Reaction
In this work, we present an innovative system for the rapid detection of bacterial contamination in water samples, exploiting chemiluminescence reaction in the presence of bacterial adenosine triphosphate (ATP). It is formed by a closed box in which reagents and ATP from water samples are put in a spectrophotometric-grade quartz cuvette on a silicon photomultiplier (SiPM) that converts the photons revealed into electrical signals. A commercial kit for bacterial load detection in water samples employing ATP chemiluminescent reaction was tested, and its filtration and lysis efficiencies were assessed. A comparison between the new system and the luminometer, the standard device for chemiluminescence detection, was then conducted. Firstly, calibration curves for both systems were obtained using different ATP concentrations, resulting in a Limit of Detection (LoD) of 0.03 nM for the SiPM-based system and 0.01 nM for the luminometer. Afterwards, water samples artificially contaminated with E. coli were prepared to compare the detection efficiency of both systems using the commercial kit for sample processing. A cultural method analysis was also conducted to validate the obtained results. ATP concentrations derived from the three detection strategies showed great consistency, underlying the high sensitivity of the new low-cost, miniaturizable and potentially remotely controlled system developed.
- 24 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 319-324
Development of a New System for Bacterial Load Detection in Water Samples Exploiting ATP Chemiluminescence Reaction
In this work, we present an innovative system for the rapid detection of bacterial contamination in water samples, exploiting chemiluminescence reaction in the presence of bacterial adenosine triphosphate (ATP). It is formed by a closed box in which reagents and ATP from water samples are put in a spectrophotometric-grade quartz cuvette on a silicon photomultiplier (SiPM) that converts the photons revealed into electrical signals. A commercial kit for bacterial load detection in water samples employing ATP chemiluminescent reaction was tested, and its filtration and lysis efficiencies were assessed. A comparison between the new system and the luminometer, the standard device for chemiluminescence detection, was then conducted. Firstly, calibration curves for both systems were obtained using different ATP concentrations, resulting in a Limit of Detection (LoD) of 0.03 nM for the SiPM-based system and 0.01 nM for the luminometer. Afterwards, water samples artificially contaminated with E. coli were prepared to compare the detection efficiency of both systems using the commercial kit for sample processing. A cultural method analysis was also conducted to validate the obtained results. ATP concentrations derived from the three detection strategies showed great consistency, underlying the high sensitivity of the new low-cost, miniaturizable and potentially remotely controlled system developed.
- 24 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 147-151
Development and Optimization of a Miniaturizable System for ATP Detection in Water Samples
This work presents the design and optimization of a miniaturizable, high-sensitivity system for real-time detection of adenosine triphosphate (ATP)-the primary energy carrier in biological systems-in water samples. Detection was based on the chemiluminescent ATP-luciferin driven reaction, monitored using a silicon photomultiplier (SiPM). Three different set-up configurations were investigated, focusing on the effects of reaction chamber size and total solution volume. The system achieved a minimum detectable ATP concentration of 0.05 nM, with a limit of detection (LoD) of 0.03 nM and a sensitivity of 11.9 A/M.
- 24 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 147-151
Development and Optimization of a Miniaturizable System for ATP Detection in Water Samples
This work presents the design and optimization of a miniaturizable, high-sensitivity system for real-time detection of adenosine triphosphate (ATP)-the primary energy carrier in biological systems-in water samples. Detection was based on the chemiluminescent ATP-luciferin driven reaction, monitored using a silicon photomultiplier (SiPM). Three different set-up configurations were investigated, focusing on the effects of reaction chamber size and total solution volume. The system achieved a minimum detectable ATP concentration of 0.05 nM, with a limit of detection (LoD) of 0.03 nM and a sensitivity of 11.9 A/M.
- 24 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 273-277
Real-Time Detection of Mercury in Water with a Bacterial Bioluminescent Silicon Photomultiplier System
This study presents a compact and highly sensitive optoelectronic biosensing system that integrates genetically engineered Escherichia coli bacteria with a Silicon Photomultiplier-based detection module for monitoring mercury in aquatic environments. The engineered bacteria produce bioluminescent signals in response to mercury exposure, with light intensity directly proportional to the concentration of bioavailable metal ions. By combining the high photon detection efficiency and low-noise performance of Silicon Photomultipliers with a custom-built acquisition interface, our system enables real-time monitoring of pollutants at trace levels. Additionally, the multi-chamber configuration supports simultaneous measurements under different conditions, facilitating direct biosensor calibration and enhancing the reliability of statistical analysis. Measurements demonstrate a Limit of Detection of 0.12 μg/L, eight times below current environmental regulatory thresholds, and a dynamic range spanning about two orders of magnitude. Compared to a conventional laboratory-grade luminometer, our system achieves equivalent sensitivity while offering significant advantages in terms of portability, cost, and remote control. These features highlight its strong potential for environmental monitoring and risk assessment.
- 24 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 273-277
Real-Time Detection of Mercury in Water with a Bacterial Bioluminescent Silicon Photomultiplier System
This study presents a compact and highly sensitive optoelectronic biosensing system that integrates genetically engineered Escherichia coli bacteria with a Silicon Photomultiplier-based detection module for monitoring mercury in aquatic environments. The engineered bacteria produce bioluminescent signals in response to mercury exposure, with light intensity directly proportional to the concentration of bioavailable metal ions. By combining the high photon detection efficiency and low-noise performance of Silicon Photomultipliers with a custom-built acquisition interface, our system enables real-time monitoring of pollutants at trace levels. Additionally, the multi-chamber configuration supports simultaneous measurements under different conditions, facilitating direct biosensor calibration and enhancing the reliability of statistical analysis. Measurements demonstrate a Limit of Detection of 0.12 μg/L, eight times below current environmental regulatory thresholds, and a dynamic range spanning about two orders of magnitude. Compared to a conventional laboratory-grade luminometer, our system achieves equivalent sensitivity while offering significant advantages in terms of portability, cost, and remote control. These features highlight its strong potential for environmental monitoring and risk assessment.
- Open Access
Electrocatalytical Nitrite Oxidation via Manganese and Copper Oxides on Carbon Screen-Printed Electrode
Nitrite (NO2−) has long been recognized as a contaminant of concern due to its detrimental effects on both human health and the environment. As a result, there is a continuing need to develop sensitive, real-time, low-cost, and portable systems for the accurate detection of trace levels of NO2− in drinking water. We present a novel, low-cost, and easy-to-fabricate amperometric sensor designed for detecting low concentrations of NO2− in drinking water. The fabrication technique involves the electrodeposition of manganese and copper oxides onto a carbon working electrode. CuO and MnO2 act synergistically as efficient catalysts for the electrooxidation of nitrite to nitrate (NO3−) thanks to their complementary redox properties. The resulting sensor exhibits high catalytic activity toward the electrooxidation of NO2−, with a sensitivity of 10.83 μA/µM, a limit of detection (LOD) of 0.071 µM, and a good linear dynamic concentration range (0.2–60 µM). The sensor’s performance was evaluated against potential interfering analytes (NO3−, Cl−, NH4+, and NH2Cl), all of which showed negligible interference. Reproducibility (maximum standard deviation 2.91%) and repeatability (usable up to three times) were also evaluated.
Open AccessElectrocatalytical Nitrite Oxidation via Manganese and Copper Oxides on Carbon Screen-Printed Electrode
Nitrite (NO2−) has long been recognized as a contaminant of concern due to its detrimental effects on both human health and the environment. As a result, there is a continuing need to develop sensitive, real-time, low-cost, and portable systems for the accurate detection of trace levels of NO2− in drinking water. We present a novel, low-cost, and easy-to-fabricate amperometric sensor designed for detecting low concentrations of NO2− in drinking water. The fabrication technique involves the electrodeposition of manganese and copper oxides onto a carbon working electrode. CuO and MnO2 act synergistically as efficient catalysts for the electrooxidation of nitrite to nitrate (NO3−) thanks to their complementary redox properties. The resulting sensor exhibits high catalytic activity toward the electrooxidation of NO2−, with a sensitivity of 10.83 μA/µM, a limit of detection (LOD) of 0.071 µM, and a good linear dynamic concentration range (0.2–60 µM). The sensor’s performance was evaluated against potential interfering analytes (NO3−, Cl−, NH4+, and NH2Cl), all of which showed negligible interference. Reproducibility (maximum standard deviation 2.91%) and repeatability (usable up to three times) were also evaluated.
- 2 October 2024
- Published by American Chemical Society (ACS) in ACS Medicinal Chemistry Letters
- Vol. 15 (11) , 1875-1883
Pursuing Polypharmacology: Benzothiopyranoindoles as G-Quadruplex Stabilizers and Topoisomerase I Inhibitors for Effective Anticancer Strategies
Here, we explored the benzothiopyranoindole scaffold to develop antiproliferative agents with a polypharmacological profile targeting both G-quadruplex (G4)-structures and Topoisomerase (Topo) I enzyme. In a preliminary optimization phase, compound 1 was selected from an in-house collection as a suitable lead for the rational development of a small library of analogs (2-5). When assayed in NIH's NCI-60 Human Cancer Cell Line In Vitro Screen Program, compound 1 and its demethylated analogue 2 showed significant antiproliferative/cytotoxic activity. Furthermore, results suggested for 1 and 2 a dual mechanism of action, effectively binding and stabilizing G4 structures, while inhibiting the relaxation activity of TopoI and II. Notably, these compounds displayed a certain selectivity toward TopoI. The polypharmacological profile of 1 and 2 was validated in a human colon carcinoma cell line, underscoring their potential as lead candidates for developing novel and efficacious anticancer agents.
- 2 October 2024
- Published by American Chemical Society (ACS) in ACS Medicinal Chemistry Letters
- Vol. 15 (11) , 1875-1883
Pursuing Polypharmacology: Benzothiopyranoindoles as G-Quadruplex Stabilizers and Topoisomerase I Inhibitors for Effective Anticancer Strategies
Here, we explored the benzothiopyranoindole scaffold to develop antiproliferative agents with a polypharmacological profile targeting both G-quadruplex (G4)-structures and Topoisomerase (Topo) I enzyme. In a preliminary optimization phase, compound 1 was selected from an in-house collection as a suitable lead for the rational development of a small library of analogs (2-5). When assayed in NIH's NCI-60 Human Cancer Cell Line In Vitro Screen Program, compound 1 and its demethylated analogue 2 showed significant antiproliferative/cytotoxic activity. Furthermore, results suggested for 1 and 2 a dual mechanism of action, effectively binding and stabilizing G4 structures, while inhibiting the relaxation activity of TopoI and II. Notably, these compounds displayed a certain selectivity toward TopoI. The polypharmacological profile of 1 and 2 was validated in a human colon carcinoma cell line, underscoring their potential as lead candidates for developing novel and efficacious anticancer agents.
- 14 September 2024
- Published by American Chemical Society (ACS) in Journal of Chemical Information and Modeling
- Vol. 64 (21) , 8299-8309
Discovering Dually Active Anti-cancer Compounds with a Hybrid AI-structure-based Approach
Cancer's persistent growth often relies on its ability to maintain telomere length and tolerate the accumulation of DNA damage. This study explores a computational approach to identify compounds that can simultaneously target both G-quadruplex (G4) structures and poly(ADP-ribose) polymerase (PARP)1 enzyme, offering a potential multipronged attack on cancer cells. We employed a hybrid virtual screening (VS) protocol, combining the power of machine learning with traditional structure-based methods. PyRMD, our AI-powered tool, was first used to analyze vast chemical libraries and to identify potential PARP1 inhibitors based on known bioactivity data. Subsequently, a structure-based VS approach selected compounds from these identified inhibitors for their G4 stabilization potential. This two-step process yielded 50 promising candidates, which were then experimentally validated for their ability to inhibit PARP1 and stabilize G4 structures. Ultimately, four lead compounds emerged as promising candidates with the desired dual activity and demonstrated antiproliferative effects against specific cancer cell lines. This study highlights the potential of combining Artificial Intelligence and structure-based methods for the discovery of multitarget anticancer compounds, offering a valuable approach for future drug development efforts.
- 14 September 2024
- Published by American Chemical Society (ACS) in Journal of Chemical Information and Modeling
- Vol. 64 (21) , 8299-8309
Discovering Dually Active Anti-cancer Compounds with a Hybrid AI-structure-based Approach
Cancer's persistent growth often relies on its ability to maintain telomere length and tolerate the accumulation of DNA damage. This study explores a computational approach to identify compounds that can simultaneously target both G-quadruplex (G4) structures and poly(ADP-ribose) polymerase (PARP)1 enzyme, offering a potential multipronged attack on cancer cells. We employed a hybrid virtual screening (VS) protocol, combining the power of machine learning with traditional structure-based methods. PyRMD, our AI-powered tool, was first used to analyze vast chemical libraries and to identify potential PARP1 inhibitors based on known bioactivity data. Subsequently, a structure-based VS approach selected compounds from these identified inhibitors for their G4 stabilization potential. This two-step process yielded 50 promising candidates, which were then experimentally validated for their ability to inhibit PARP1 and stabilize G4 structures. Ultimately, four lead compounds emerged as promising candidates with the desired dual activity and demonstrated antiproliferative effects against specific cancer cell lines. This study highlights the potential of combining Artificial Intelligence and structure-based methods for the discovery of multitarget anticancer compounds, offering a valuable approach for future drug development efforts.