Mohd Farman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mohd Farman has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Eshwar Thouti
Centre for Energy Studies, Indian Institute of Technology Delhi, New Delhi 110016, India
2 shared publications - Achu Chandran
Materials Science and Technology Division CSIR‐National Institute for Interdisciplinary Science and Technology (NIIST) Thiruvananthapuram 695019 India
1 shared publication Deepak Kumar Panwar
Semiconductor Device Fabrication Facility Group, CSIR-CEERI, Pilani 333031, India
1 shared publication- Gaurav Purohit
Advanced Information Technologies Group, CSIR-Central Electronics Engineering Research Institute (CSIR-CEERI), Pilani, Rajasthan, India
1 shared publication - Harris Varghese
Materials Science and Technology Division CSIR‐National Institute for Interdisciplinary Science and Technology (NIIST) Thiruvananthapuram 695019 India
1 shared publication Hasna M. Abdul Hakkeem
Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, 201002, India
1 shared publication
Latest Publications
- 24 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (4) , 5606-5613
Flexible Piezoresistive Strain Sensors Using Ternary Conductive Hybrid Nanocomposites Integrated Into Wearable Smart Gloves for Human–Machine Interface
We report flexible piezoresistive strain sensors containing poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS), graphene nanoplatelet (GNP), and polydimethylsiloxane (PDMS)-based ternary conductive hybrid nanocomposites as an active sensing layer fabricated using a simple solution-processed technique. The sensors have been fabricated on flexible PDMS substrate which is patterned using emery papers having grit size of 80 and 100. The electrical characterization has been undertaken in PDMS-based flexible devices mounted on smart gloves with structures PEDOT:PSS/GNP/PDMS. The microscopic study of the microstructured PDMS is done using field emission scanning electron microscopy (FESEM). The size of PDMS microstructure based on 80-grit and 100-grit emery papers is found to be in the range of 165–196 and 121–148 μm, respectively. FTIR peaks at 677, 930, ~1000–1110, and 1519 cm−1 signify the C–S, S–O, Si–O–Si, and C=C stretching, respectively. From X-ray diffraction (XRD), the diffraction peak at 26.60° corresponds to 002 facets of GNP, whereas PEDOT:PSS showed no distinct peaks of PEDOT:PSS film indicating amorphous nature of the polymer. The gauge factor (GF) of the sensor based on 80-grit emery paper is determined to be 601.3 within the strain ranging from 0% to 46%. The sensor shows highly reproducible response over 2100 bending and stretching cycles suggesting long-term durability. Response and recovery time of the fabricated sensor is calculated to be 140 and 155 ms, respectively. The developed smart glove integrated flexible strain sensor is capable to detect human pulse and monitor the real-time human motions, and therefore, it may find a great promise for application in smart wearable electronics and human–machine interface.
- 24 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (4) , 5606-5613
Flexible Piezoresistive Strain Sensors Using Ternary Conductive Hybrid Nanocomposites Integrated Into Wearable Smart Gloves for Human–Machine Interface
We report flexible piezoresistive strain sensors containing poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS), graphene nanoplatelet (GNP), and polydimethylsiloxane (PDMS)-based ternary conductive hybrid nanocomposites as an active sensing layer fabricated using a simple solution-processed technique. The sensors have been fabricated on flexible PDMS substrate which is patterned using emery papers having grit size of 80 and 100. The electrical characterization has been undertaken in PDMS-based flexible devices mounted on smart gloves with structures PEDOT:PSS/GNP/PDMS. The microscopic study of the microstructured PDMS is done using field emission scanning electron microscopy (FESEM). The size of PDMS microstructure based on 80-grit and 100-grit emery papers is found to be in the range of 165–196 and 121–148 μm, respectively. FTIR peaks at 677, 930, ~1000–1110, and 1519 cm−1 signify the C–S, S–O, Si–O–Si, and C=C stretching, respectively. From X-ray diffraction (XRD), the diffraction peak at 26.60° corresponds to 002 facets of GNP, whereas PEDOT:PSS showed no distinct peaks of PEDOT:PSS film indicating amorphous nature of the polymer. The gauge factor (GF) of the sensor based on 80-grit emery paper is determined to be 601.3 within the strain ranging from 0% to 46%. The sensor shows highly reproducible response over 2100 bending and stretching cycles suggesting long-term durability. Response and recovery time of the fabricated sensor is calculated to be 140 and 155 ms, respectively. The developed smart glove integrated flexible strain sensor is capable to detect human pulse and monitor the real-time human motions, and therefore, it may find a great promise for application in smart wearable electronics and human–machine interface.
- 1 October 2024
- Published by IOP Publishing in Flexible and Printed Electronics
- Vol. 9 (4) , 045003
Cleanroom-free fabrication of flexible capacitive pressure sensors using paintable silver electrodes on stationery paper and random microstructured polydimethylsiloxane dielectric layer
In this work, we propose a facile, low-cost, and cleanroom-free approach for fabricating flexible capacitive pressure sensors based on paintable Ag electrodes on stationery paper substrates (Ag–paper electrodes) and a random microstructured polydimethylsiloxane (PDMS) dielectric layer transferred from emery paper. COMSOL Multiphysics simulations and experimental investigations suggest that the pressure sensor with random microstructured PDMS dielectric layer performs better than the sensor with ordered micropyramidal dielectric layer. The developed Ag–paper electrode and random microstructured PDMS dielectric layer-based pressure sensors are workable in a wide pressure range (up to 630 kPa) and exhibit a high sensitivity of 0.132 kPa−1 up to 1 kPa, low hysteresis (6.6%) with loading–unloading of ∼500 kPa pressure, high stability during a ∼5250 cyclic test, and the ability to sense a low pressure of ∼27 Pa. The developed sensor also successfully transduces arterial pulse wave forms when it is properly attached to the wrist. Using the proposed process, a flexible capacitive pressure sensor matrix of 4 × 4 array is also successfully developed for single- and multiple-point pressure mapping with minimal cross-talk. The proposed sensor process is simple and inexpensive to implement, and offers spatial pressure mapping for e-skin applications.
- 1 October 2024
- Published by IOP Publishing in Flexible and Printed Electronics
- Vol. 9 (4) , 045003
Cleanroom-free fabrication of flexible capacitive pressure sensors using paintable silver electrodes on stationery paper and random microstructured polydimethylsiloxane dielectric layer
In this work, we propose a facile, low-cost, and cleanroom-free approach for fabricating flexible capacitive pressure sensors based on paintable Ag electrodes on stationery paper substrates (Ag–paper electrodes) and a random microstructured polydimethylsiloxane (PDMS) dielectric layer transferred from emery paper. COMSOL Multiphysics simulations and experimental investigations suggest that the pressure sensor with random microstructured PDMS dielectric layer performs better than the sensor with ordered micropyramidal dielectric layer. The developed Ag–paper electrode and random microstructured PDMS dielectric layer-based pressure sensors are workable in a wide pressure range (up to 630 kPa) and exhibit a high sensitivity of 0.132 kPa−1 up to 1 kPa, low hysteresis (6.6%) with loading–unloading of ∼500 kPa pressure, high stability during a ∼5250 cyclic test, and the ability to sense a low pressure of ∼27 Pa. The developed sensor also successfully transduces arterial pulse wave forms when it is properly attached to the wrist. Using the proposed process, a flexible capacitive pressure sensor matrix of 4 × 4 array is also successfully developed for single- and multiple-point pressure mapping with minimal cross-talk. The proposed sensor process is simple and inexpensive to implement, and offers spatial pressure mapping for e-skin applications.
- Open Access
- 20 July 2022
- Published by Elsevier in Results in Engineering
- Vol. 16, 100550
Self-powered flexible triboelectric touch sensor based on micro-pyramidal PDMS films and cellulose acetate nanofibers
- 20 July 2022
- Published by Elsevier in Results in Engineering
- Vol. 16, 100550
Open AccessSelf-powered flexible triboelectric touch sensor based on micro-pyramidal PDMS films and cellulose acetate nanofibers