Julian Decker has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Clinical Whole-Body Gait Characterization Using a Single RGB-D Sensor

    by Lukas Boborzi, Johannes Bertram, Roman Schniepp, Julian Decker, Max Wuehr

    Instrumented gait analysis is widely used in clinical settings for the early detection of neurological disorders, monitoring disease progression, and evaluating fall risk. However, the gold-standard marker-based 3D motion analysis is limited by high time and personnel demands. Advances in computer vision now enable markerless whole-body tracking with high accuracy. Here, we present vGait, a comprehensive 3D gait assessment method using a single RGB-D sensor and state-of-the-art pose-tracking algorithms. vGait was validated in healthy participants during frontal- and sagittal-perspective walking. Performance was comparable across perspectives, with vGait achieving high accuracy in detecting initial and final foot contacts (F1 scores > 95%) and reliably quantifying spatiotemporal gait parameters (e.g., stride time, stride length) and whole-body coordination metrics (e.g., arm swing and knee angle ROM) at different levels of granularity (mean, step-to-step variability, side asymmetry). The flexibility, accuracy, and minimal resource requirements of vGait make it a valuable tool for clinical and non-clinical applications, including outpatient clinics, medical practices, nursing homes, and community settings. By enabling efficient and scalable gait assessment, vGait has the potential to enhance diagnostic and therapeutic workflows and improve access to clinical mobility monitoring.


  • Open Access

    Clinical Whole-Body Gait Characterization Using a Single RGB-D Sensor

    by Lukas Boborzi, Johannes Bertram, Roman Schniepp, Julian Decker, Max Wuehr

    Instrumented gait analysis is widely used in clinical settings for early detection of neurological disorders, monitoring disease progression, and evaluating fall risk. However, the gold-standard marker-based 3D motion analysis is limited by high time and personnel demands. Advances in computer vision now enable markerless whole-body tracking with high accuracy. Here, we present vGait, a comprehensive 3D gait assessment method using a single RGB-D sensor and state-of-the-art pose tracking algorithms. vGait was validated in healthy participants during frontal and sagittal perspective walking. Performance was comparable across perspectives, with vGait achieving high accuracy in detecting initial and final foot contacts (F1 scores > 95%) and reliably quantifying spatiotemporal gait parameters (e.g., stride time, stride length) and whole-body coordination metrics (e.g., arm swing and knee angle ROM) at different levels of granularity (mean, step-to-step variability, side asymmetry). The flexibility, accuracy, and minimal resource requirements of vGait make it a valuable tool for clinical and non-clinical applications, including outpatient clinics, medical practices, nursing homes, or community settings. By enabling efficient and scalable gait assessment, vGait has the potential to enhance diagnostic and therapeutic workflows and improve access to clinical mobility monitoring.

  • Open Access

    Mobile Spatiotemporal Gait Segmentation Using an Ear-Worn Motion Sensor and Deep Learning

    by Julian Decker, Lukas Boborzi, Roman Schniepp, Klaus Jahn, Max Wuehr

    Mobile health technologies enable continuous, quantitative assessment of mobility and gait in real-world environments, facilitating early diagnoses of gait disorders, disease progression monitoring, and prediction of adverse events like falls. Traditionally, mobile gait assessment predominantly relied on body-fixed sensors positioned at the feet or lower trunk. Here, we investigate the potential of an algorithm utilizing an ear-worn motion sensor for spatiotemporal segmentation of gait patterns. We collected 3D acceleration profiles from the ear-worn sensor during varied walking speeds in 53 healthy adults. Temporal convolutional networks were trained to detect stepping sequences and predict spatial relations between steps. The resulting algorithm, mEar, accurately detects initial and final ground contacts (F1 score of 99% and 91%, respectively). It enables the determination of temporal and spatial gait cycle characteristics (among others, stride time and stride length) with good to excellent validity at a precision sufficient to monitor clinically relevant changes in walking speed, stride-to-stride variability, and side asymmetry. This study highlights the ear as a viable site for monitoring gait and proposes its potential integration with in-ear vital-sign monitoring. Such integration offers a practical approach to comprehensive health monitoring and telemedical applications, by integrating multiple sensors in a single anatomical location.


  • Open Access

    Mobile Spatiotemporal Gait Segmentation Using an Ear-Worn Motion Sensor and Deep Learning

    by Julian Decker, Lukas Boborzi, Roman Schniepp, Klaus Jahn, Max Wuehr

    Mobile health technologies enable continuous, quantitative assessment of mobility and gait in real-world environments, facilitating early diagnosis of gait disorders, disease progression monitoring, and prediction of adverse events like falls. Traditionally, mobile gait assessment predominantly relied on body-fixed sensors positioned at the feet or lower trunk. Here, we investigate the potential of an algorithm utilizing an ear-worn motion sensor for spatiotemporal segmentation of gait patterns. We collected 3D acceleration profiles from the ear-worn sensor during varied walking speeds in 53 healthy adults. Temporal convolutional networks were trained to detect stepping sequences and predict spatial relations between steps. The resulting algorithm, mEar, accurately detects initial and final ground contacts (F1 score of 99% and 91%, respectively). It enables determination of temporal and spatial gait cycle characteristics (among others stride time and stride length) with good to excellent validity at a precision sufficient to monitor clinically relevant changes in walking speed, stride-to-stride variability, and side asymmetry. This study highlights the ear as a viable site for monitoring gait and proposes its potential integration with in-ear vital sign monitoring. Such integration offers a practical approach to comprehensive health monitoring and telemedical applications, by integrating multiple sensors in a single anatomical location.


  • Open Access

    Precision Balance Assessment in Parkinson’s Disease: Utilizing Vision-Based 3D Pose Tracking for Pull Test Analysis

    by Nina Ellrich, Kasimir Niermeyer, Daniela Peto, Julian Decker, Urban M. Fietzek, Sabrina Katzdobler, Günter U. Höglinger, Klaus Jahn, Andreas Zwergal, Max Wuehr

    Postural instability is a common complication in advanced Parkinson’s disease (PD) associated with recurrent falls and fall-related injuries. The test of retropulsion, consisting of a rapid balance perturbation by a pull in the backward direction, is regarded as the gold standard for evaluating postural instability in PD and is a key component of the neurological examination and clinical rating in PD (e.g., MDS-UPDRS). However, significant variability in test execution and interpretation contributes to a low intra- and inter-rater test reliability. Here, we explore the potential for objective, vision-based assessment of the pull test (vPull) using 3D pose tracking applied to single-sensor RGB-Depth recordings of clinical assessments. The initial results in a cohort of healthy individuals (n = 15) demonstrate overall excellent agreement of vPull-derived metrics with the gold standard marker-based motion capture. Subsequently, in a cohort of PD patients and controls (n = 15 each), we assessed the inter-rater reliability of vPull and analyzed PD-related impairments in postural response (including pull-to-step latency, number of steps, retropulsion angle). These quantitative metrics effectively distinguish healthy performance from and within varying degrees of postural impairment in PD. vPull shows promise for straightforward clinical implementation with the potential to enhance the sensitivity and specificity of postural instability assessment and fall risk prediction in PD.


  • Open Access

    Human Activity Recognition in a Free-Living Environment Using an Ear-Worn Motion Sensor

    by Lukas Boborzi, Julian Decker, Razieh Rezaei, Roman Schniepp, Max Wuehr

    Human activity recognition (HAR) technology enables continuous behavior monitoring, which is particularly valuable in healthcare. This study investigates the viability of using an ear-worn motion sensor for classifying daily activities, including lying, sitting/standing, walking, ascending stairs, descending stairs, and running. Fifty healthy participants (between 20 and 47 years old) engaged in these activities while under monitoring. Various machine learning algorithms, ranging from interpretable shallow models to state-of-the-art deep learning approaches designed for HAR (i.e., DeepConvLSTM and ConvTransformer), were employed for classification. The results demonstrate the ear sensor’s efficacy, with deep learning models achieving a 98% accuracy rate of classification. The obtained classification models are agnostic regarding which ear the sensor is worn and robust against moderate variations in sensor orientation (e.g., due to differences in auricle anatomy), meaning no initial calibration of the sensor orientation is required. The study underscores the ear’s efficacy as a suitable site for monitoring human daily activity and suggests its potential for combining HAR with in-ear vital sign monitoring. This approach offers a practical method for comprehensive health monitoring by integrating sensors in a single anatomical location. This integration facilitates individualized health assessments, with potential applications in tele-monitoring, personalized health insights, and optimizing athletic training regimes.


  • Open Access

    Human Activity Recognition in a Free-Living Environment Using an Ear-Worn Motion Sensor

    by Lukas Boborzi, Julian Decker, Razieh Rezaei, Roman Schniepp, Max Wuehr

    Human Activity Recognition (HAR) technology enables continuous behavior monitoring, particularly valuable in healthcare. This study investigates the viability of using an ear-worn motion sensor for classifying daily activities, including lying, sitting/standing, walking, ascending stairs, descending stairs, and running. Fifty healthy participants (between 20 and 47 years old) engaged in these activities while under monitoring. Various machine learning algorithms, ranging from interpretable shallow models to state-of-the-art deep learning approaches designed for HAR, were employed for classification. Results demonstrate the ear sensor's efficacy, with deep learning models achieving 98% accuracy rate of classification. The obtained classification models are agnostic regarding which ear the sensor is worn and robust against moderate variations in sensor orientation (e.g., due to differences in auricle anatomy), meaning no initial calibration of the sensor orientation is required. The study underscores the ear's efficacy as a suitable site for monitoring human daily activity and suggests its potential for combining HAR with in-ear vital signs monitoring. This approach offers a practical method for comprehensive health monitoring by integrating sensors in a single anatomical location. This integration facilitates individualized health assessments, with potential applications in tele-monitoring, personalized health insights, and optimizing athletic training regimes.