Roman Sokiranski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Roman Sokiranski has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
A J Aschoff
1 shared publicationA. Bormann
Klinik für Radiologie, Interventionsradiologie und Neuroradiologie, Klinikum Altenburger Land GmbH, Altenburg, Germany
1 shared publication- Andreas Winkelmann
Institute of Anatomy, Brandenburg Medical School—Theodor Fontane, D-16816 Neuruppin, Germany
1 shared publication - Anna-Maria Begerock
Macroscopic Anatomy, Medical University Lausitz—Carl Thiem, D-03048 Cottbus, Germany
1 shared publication - Evelyn Heuckendorf
Institute of Integrative Neuroanatomy, Charité—Universitätsmedizin Berlin, D-10117 Berlin, Germany
1 shared publication H J Brambs
1 shared publication
Latest Publications
- Open Access
Bioarchaeological and Anatomical Examination of a Peruvian Mummy Reveals Signs of Intentional Evisceration
Background/Objectives: The preservation of ancestors as mummies was a central element of many pre-Hispanic cultures of western South America. Here, we present our results from a bioarchaeological and anatomical investigation of a Peruvian mummy, curated today in the anatomical collection of the Charité, Berlin, Germany. The remains were collected by the Prussian physician, botanist, and explorer Franz Julius Ferdinand Meyen (1804–1840), who served as a ship’s doctor in South America from 1830 to 1832. According to Meyen, the mummy was found in a natural cave in the Andes, near Pasco, today Peru. As is often the case, all context and documentation of origin are lost today. Methods: We performed radiocarbon dating, external macroscopic examination, and computed tomography imaging. Results: According to skeletal anatomy, the mummy is that of an adult male who died in the late pre-Hispanic or Early Colonial Period. While the skin is largely well preserved, most internal organs could not be identified on CT and external genitalia are missing. An incision in the right flank communicating with the abdominal cavity and a large defect in the pelvic floor were observed. Conclusions: This Peruvian mummy represents a rare case of anthropogenic mummification with removal of the internal organs. Evisceration was likely performed through the right flank incision, with additional access routes via the pelvic floor and the mouth. However, since neither grave goods nor parts of the mummy bundle have survived, his culture of origin remains uncertain.
Open AccessBioarchaeological and Anatomical Examination of a Peruvian Mummy Reveals Signs of Intentional Evisceration
Background/Objectives: The preservation of ancestors as mummies was a central element of many pre-Hispanic cultures of western South America. Here, we present our results from a bioarchaeological and anatomical investigation of a Peruvian mummy, curated today in the anatomical collection of the Charité, Berlin, Germany. The remains were collected by the Prussian physician, botanist, and explorer Franz Julius Ferdinand Meyen (1804–1840), who served as a ship’s doctor in South America from 1830 to 1832. According to Meyen, the mummy was found in a natural cave in the Andes, near Pasco, today Peru. As is often the case, all context and documentation of origin are lost today. Methods: We performed radiocarbon dating, external macroscopic examination, and computed tomography imaging. Results: According to skeletal anatomy, the mummy is that of an adult male who died in the late pre-Hispanic or Early Colonial Period. While the skin is largely well preserved, most internal organs could not be identified on CT and external genitalia are missing. An incision in the right flank communicating with the abdominal cavity and a large defect in the pelvic floor were observed. Conclusions: This Peruvian mummy represents a rare case of anthropogenic mummification with removal of the internal organs. Evisceration was likely performed through the right flank incision, with additional access routes via the pelvic floor and the mouth. However, since neither grave goods nor parts of the mummy bundle have survived, his culture of origin remains uncertain.
- Open Access
- 26 September 2024
- Published by Springer Nature in Clinical Neuroradiology
- Vol. 35 (1) , 115-122
An Artificial Intelligence Algorithm Integrated into the Clinical Workflow Can Ensure High Quality Acute Intracranial Hemorrhage CT Diagnostic.
Purpose: Intracranial hemorrhage (ICH) is a life-threatening condition requiring rapid diagnostic and therapeutic action. This study evaluates whether Artificial intelligence (AI) can provide high-quality ICH diagnostics and turnaround times suitable for routine radiological practice. Methods: A convolutional neural network (CNN) was trained and validated to detect ICHs on DICOM images of cranial CT (CCT) scans, utilizing about 674,000 individually labeled slices. The CNN was then incorporated into a commercial AI engine and seamlessly integrated into three pilot centers in Germany. A real-world test-dataset was extracted and manually annotated by two experienced experts. The performance of the AI algorithm against the two raters was assessed and compared to the inter-rater agreement. The overall time ranging from data acquisition to the delivery of the AI results was analyzed. Results: Out of 6284 CCT examinations acquired in three different centers, 947 (15%) had ICH. Breakdowns of hemorrhage types included 8% intraparenchymal, 3% intraventricular, 6% subarachnoidal, 7% subdural, < 1% epidural hematomas. Comparing the AI’s performance on a subset of 255 patients with two expert raters, it achieved a sensitivity of 0.90, a specificity of 0.96, an accuracy of 0.96. The corresponding inter-rater agreement was 0.84, 0.98, and 0.96. The overall median processing times for the three centers were 9, 11, and 12 min, respectively. Conclusion: We showed that an AI algorithm for the automatic detection of ICHs can be seamlessly integrated into clinical workflows with minimal turnaround time. The accuracy was on par with radiology experts, making the system suitable for routine clinical use.
- 26 September 2024
- Published by Springer Nature in Clinical Neuroradiology
- Vol. 35 (1) , 115-122
Open AccessAn Artificial Intelligence Algorithm Integrated into the Clinical Workflow Can Ensure High Quality Acute Intracranial Hemorrhage CT Diagnostic.
Purpose: Intracranial hemorrhage (ICH) is a life-threatening condition requiring rapid diagnostic and therapeutic action. This study evaluates whether Artificial intelligence (AI) can provide high-quality ICH diagnostics and turnaround times suitable for routine radiological practice. Methods: A convolutional neural network (CNN) was trained and validated to detect ICHs on DICOM images of cranial CT (CCT) scans, utilizing about 674,000 individually labeled slices. The CNN was then incorporated into a commercial AI engine and seamlessly integrated into three pilot centers in Germany. A real-world test-dataset was extracted and manually annotated by two experienced experts. The performance of the AI algorithm against the two raters was assessed and compared to the inter-rater agreement. The overall time ranging from data acquisition to the delivery of the AI results was analyzed. Results: Out of 6284 CCT examinations acquired in three different centers, 947 (15%) had ICH. Breakdowns of hemorrhage types included 8% intraparenchymal, 3% intraventricular, 6% subarachnoidal, 7% subdural, < 1% epidural hematomas. Comparing the AI’s performance on a subset of 255 patients with two expert raters, it achieved a sensitivity of 0.90, a specificity of 0.96, an accuracy of 0.96. The corresponding inter-rater agreement was 0.84, 0.98, and 0.96. The overall median processing times for the three centers were 9, 11, and 12 min, respectively. Conclusion: We showed that an AI algorithm for the automatic detection of ICHs can be seamlessly integrated into clinical workflows with minimal turnaround time. The accuracy was on par with radiology experts, making the system suitable for routine clinical use.
- Open Access
- 1 December 1997
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 169 (6) , 1529-1533
Displaced metallic biliary stents: technique and rationale for interventional radiologic retrieval.
We investigated the spontaneous course and the possibility of transhepatic removal of displaced biliary stents. Displaced biliary stents were observed in 11 patients (13-75 years old) between October 1988 and August 1996. Stent types included the Palmaz stent (n = 3), Wallstent (n = 3), and the Strecker stent (n = 5). Reasons for stent displacement included primary misplacement (n = 4), dislocation due to transhepatic endoscopy with biopsy (n = 2), dislocation resulting from a recanalization maneuver in stent occlusion (n = 3), and unknown causes (n = 2). In three cases, the stent was displaced into the proximal bile duct system. Seven patients had primary malignancy. Eight of 11 displaced biliary stents were removed transhepatically. Extraction was performed using either a wire loop (n = 4) or forceps (n = 4). No complications occurred. In the remaining three patients, whose stents were displaced into the intestine, no invasive action was taken. In one of these patients, a Palmaz stent was passed spontaneously after 1 week. In the second of these patients, a 6 cm Wallstent remained innocuously at a position in the right lower abdomen, and the patient died as a result of malignancy. In the third patient, who had a 10-cm Wallstent, an abscess developed in the stent region 4 months after displacement and resulted in formation of an ileocutaneous fistula. Transhepatic extraction of displaced biliary stents is technically possible, even in the case of rigid stents such as the Palmaz stent. Because of the risk of intestinal perforation, displaced stents should be removed.
- 1 December 1997
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 169 (6) , 1529-1533
Open AccessDisplaced metallic biliary stents: technique and rationale for interventional radiologic retrieval.
We investigated the spontaneous course and the possibility of transhepatic removal of displaced biliary stents. Displaced biliary stents were observed in 11 patients (13-75 years old) between October 1988 and August 1996. Stent types included the Palmaz stent (n = 3), Wallstent (n = 3), and the Strecker stent (n = 5). Reasons for stent displacement included primary misplacement (n = 4), dislocation due to transhepatic endoscopy with biopsy (n = 2), dislocation resulting from a recanalization maneuver in stent occlusion (n = 3), and unknown causes (n = 2). In three cases, the stent was displaced into the proximal bile duct system. Seven patients had primary malignancy. Eight of 11 displaced biliary stents were removed transhepatically. Extraction was performed using either a wire loop (n = 4) or forceps (n = 4). No complications occurred. In the remaining three patients, whose stents were displaced into the intestine, no invasive action was taken. In one of these patients, a Palmaz stent was passed spontaneously after 1 week. In the second of these patients, a 6 cm Wallstent remained innocuously at a position in the right lower abdomen, and the patient died as a result of malignancy. In the third patient, who had a 10-cm Wallstent, an abscess developed in the stent region 4 months after displacement and resulted in formation of an ileocutaneous fistula. Transhepatic extraction of displaced biliary stents is technically possible, even in the case of rigid stents such as the Palmaz stent. Because of the risk of intestinal perforation, displaced stents should be removed.