Jiaming Xie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jiaming Xie has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Wenping Wang
Texas A&M University, College Station, USA
2 shared publications - Chong Ma
School of Computing and Artificial Intelligence, Southwest Jiaotong University, Chengdu, Sichuan, China
1 shared publication Congyi Zhang
University of Hong Kong, Hong Kong
1 shared publication- Dinggang Shen
ShanghaiTech University
1 shared publication - Guangshun Wei
School of Software, Shandong University, Jinan, China
1 shared publication - Guodong Wei
South China University of Technology, Guangzhou, China
1 shared publication
Latest Publications
- 30 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Visualization and Computer Graphics
- Vol. 31 (9) , 5726-5740
Tooth Motion Monitoring in Orthodontic Treatment by Mobile Device-Based Multi-View Stereo
Nowadays, orthodontics has become an important part of modern personal life to assist one in improving mastication and raising self-esteem. However, the quality of orthodontic treatment still heavily relies on the empirical evaluation of experienced doctors, which lacks quantitative assessment and requires patients to visit clinics frequently for in-person examination. To resolve the aforementioned problem, we propose a novel and practical mobile device-based framework for precisely measuring tooth movement in treatment, so as to simplify and strengthen the traditional tooth monitoring process. To this end, we formulate the tooth movement monitoring task as a multi-view multi-object pose estimation problem via different views that capture multiple texture-less and severely occluded objects (i.e. teeth). Specifically, we exploit a pre-scanned 3D tooth model and a sparse set of multi-view tooth images as inputs for our proposed tooth monitoring framework. After extracting tooth contours and localizing the initial camera pose of each view from the initial configuration, we propose a joint pose estimation scheme to precisely estimate the 3D pose of each individual tooth, so as to infer their relative offsets during treatment. Furthermore, we introduce the metric of Relative Pose Bias to evaluate the individual tooth pose accuracy in a small scale. We demonstrate that our approach is capable of reaching high accuracy and efficiency as practical orthodontic treatment monitoring requires.
- 30 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Visualization and Computer Graphics
- Vol. 31 (9) , 5726-5740
Tooth Motion Monitoring in Orthodontic Treatment by Mobile Device-Based Multi-View Stereo
Nowadays, orthodontics has become an important part of modern personal life to assist one in improving mastication and raising self-esteem. However, the quality of orthodontic treatment still heavily relies on the empirical evaluation of experienced doctors, which lacks quantitative assessment and requires patients to visit clinics frequently for in-person examination. To resolve the aforementioned problem, we propose a novel and practical mobile device-based framework for precisely measuring tooth movement in treatment, so as to simplify and strengthen the traditional tooth monitoring process. To this end, we formulate the tooth movement monitoring task as a multi-view multi-object pose estimation problem via different views that capture multiple texture-less and severely occluded objects (i.e. teeth). Specifically, we exploit a pre-scanned 3D tooth model and a sparse set of multi-view tooth images as inputs for our proposed tooth monitoring framework. After extracting tooth contours and localizing the initial camera pose of each view from the initial configuration, we propose a joint pose estimation scheme to precisely estimate the 3D pose of each individual tooth, so as to infer their relative offsets during treatment. Furthermore, we introduce the metric of Relative Pose Bias to evaluate the individual tooth pose accuracy in a small scale. We demonstrate that our approach is capable of reaching high accuracy and efficiency as practical orthodontic treatment monitoring requires.
- 27 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 44 (2) , 868-879
Integrating Eye Tracking With Grouped Fusion Networks for Semantic Segmentation on Mammogram Images
Medical image segmentation has seen great progress in recent years, largely due to the development of deep neural networks. However, unlike in computer vision, high-quality clinical data is relatively scarce, and the annotation process is often a burden for clinicians. As a result, the scarcity of medical data limits the performance of existing medical image segmentation models. In this paper, we propose a novel framework that integrates eye tracking information from experienced radiologists during the screening process to improve the performance of deep neural networks with limited data. Our approach, a grouped hierarchical network, guides the network to learn from its faults by using gaze information as weak supervision. We demonstrate the effectiveness of our framework on mammogram images, particularly for handling segmentation classes with large scale differences.We evaluate the impact of gaze information on medical image segmentation tasks and show that our method achieves better segmentation performance compared to state-of-the-art models. A robustness study is conducted to investigate the influence of distraction or inaccuracies in gaze collection. We also develop a convenient system for collecting gaze data without interrupting the normal clinical workflow. Our work offers novel insights into the potential benefits of integrating gaze information into medical image segmentation tasks.
- 27 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 44 (2) , 868-879
Integrating Eye Tracking With Grouped Fusion Networks for Semantic Segmentation on Mammogram Images
Medical image segmentation has seen great progress in recent years, largely due to the development of deep neural networks. However, unlike in computer vision, high-quality clinical data is relatively scarce, and the annotation process is often a burden for clinicians. As a result, the scarcity of medical data limits the performance of existing medical image segmentation models. In this paper, we propose a novel framework that integrates eye tracking information from experienced radiologists during the screening process to improve the performance of deep neural networks with limited data. Our approach, a grouped hierarchical network, guides the network to learn from its faults by using gaze information as weak supervision. We demonstrate the effectiveness of our framework on mammogram images, particularly for handling segmentation classes with large scale differences.We evaluate the impact of gaze information on medical image segmentation tasks and show that our method achieves better segmentation performance compared to state-of-the-art models. A robustness study is conducted to investigate the influence of distraction or inaccuracies in gaze collection. We also develop a convenient system for collecting gaze data without interrupting the normal clinical workflow. Our work offers novel insights into the potential benefits of integrating gaze information into medical image segmentation tasks.
- 10 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 434-437
The Impact of Unbalanced Condition on Short-Circuit Performance of Multi-Chip Parallel SiC MOSFETs
In the parallel SiC MOSFETs circuit, ignoring the influence of the different parameters of the chip itself, only the parasitic inductance and the initial case temperature of the SiC MOSFET are different in each branch of the parallel circuit. The difference between these two parameters causes the relationship between the total short-circuit protection threshold current of the parallel SiC MOSFET and the threshold current of each branch in the parallel circuit. Through the two SiC MOSFETs in parallel short-circuit experiments, it is found that the parasitic inductance differs by 25% and the initial case temperature differs by 400%. The peak current value of the branch with the smallest parasitic inductance and case temperature is 1.04 times than the other. The total short-circuit protection threshold current is set according to this peak current, and the total threshold current is 1.02 times than the actual threshold current. In practice, the parasitic inductance and initial case temperature of parallel SiC MOSFETs will not obviously differ. It implies that the total short-circuit protection threshold current in parallel SiC MOSFETs can be determined by multiplying the short-circuit threshold current on any of the parallel circuits in the branch by the total number of branches.
- 10 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 434-437
The Impact of Unbalanced Condition on Short-Circuit Performance of Multi-Chip Parallel SiC MOSFETs
In the parallel SiC MOSFETs circuit, ignoring the influence of the different parameters of the chip itself, only the parasitic inductance and the initial case temperature of the SiC MOSFET are different in each branch of the parallel circuit. The difference between these two parameters causes the relationship between the total short-circuit protection threshold current of the parallel SiC MOSFET and the threshold current of each branch in the parallel circuit. Through the two SiC MOSFETs in parallel short-circuit experiments, it is found that the parasitic inductance differs by 25% and the initial case temperature differs by 400%. The peak current value of the branch with the smallest parasitic inductance and case temperature is 1.04 times than the other. The total short-circuit protection threshold current is set according to this peak current, and the total threshold current is 1.02 times than the actual threshold current. In practice, the parasitic inductance and initial case temperature of parallel SiC MOSFETs will not obviously differ. It implies that the total short-circuit protection threshold current in parallel SiC MOSFETs can be determined by multiplying the short-circuit threshold current on any of the parallel circuits in the branch by the total number of branches.