QWQingsong Wu

Qingsong Wu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Qingsong Wu has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Image Motion Blur Mechanism-Based Measurement Method for Low-Frequency Vibration Amplitude and Direction

    by Huinan Gong, Zhenjie Zhou, Jun Pan, Ming Yang, Hongquan Ding, Xin Zhu, Qingsong Wu

    The low-frequency vibration measurement is crucial to the mechanical system dynamic performance testing, structural health monitoring, and auxiliary medical diagnostics. Machine vision has gradually been applied in low-frequency vibration measurement because of its portability, flexibility, and non-contact nature. However, the relative motion between the camera and the measured vibration object inevitably causes motion blur in the image, which decreases the measurement accuracy. To eliminate the influence of motion blur on vibration measurement performance, this study proposes a new motion blur mechanism-based low-frequency vibration measurement method. This method models the mathematical relation between stripe features and vibration parameters in the Fast Fourier Transform spectrum so that the vibration amplitude and direction can be solved from the stripe width and direction. Meanwhile, median filtering and Kaiser window are utilized to pre-process the vibration blurred images to reduce the environmental noise interference and spectrum leakage and to improve the contrast of the stripes. Additionally, the Canny edge detection method is added to Radon Transform to overcome its limitation in direction detection, so as to improve the accuracy and reliability. To avoid the problem of excessive edge smoothing in stripe edge extraction, the method improves Canny edge detection to achieve accurate localization of spectrum stripe edges. The simulation results show that the maximum relative error in amplitude was 1.7% and the maximum difference in direction was 0.19°, respectively. Experimental results from the 1-7 Hz vibration measurements indicate that the proposed method achieves a maximum relative deviation 1.8% in amplitude and a maximum difference 0.04° in direction.


  • Monocular Vision-Based Decoupling Measurement Method for Multi-Degree-of-Freedom Motion

    by Qingsong Wu, Ming Yang, Zhihua Liu, Chenguang Cai, Ying Wang, Deguang Wang

    The most common forms of target multi-degree-of-freedom (MDOF) motion include plane and space motions, whose accurate measurement is crucial for the fields of pose estimation, inertial navigation, and structural health monitoring of buildings. Currently, the primary methods used for the MDOF motion measurement are laser interferometry, grating ruler-based method, and sensor-based method. However, the laser interferometry is operationally complex, costly, and it requires strict environmental conditions. Although the grating ruler-based method is low-cost and accurate, its applicable frequency range is limited. Moreover, the sensor-based method suffers from limited accuracy and dynamic range. To achieve accurate measurement of MDOF motion across a wide frequency range, a new monocular vision (MV)-based decoupling measurement method is investigated. This method utilizes a specially designed measurement mark, combined with an improved Harris corner positioning algorithm with sub-pixel accuracy and decoupling models for plane and space motions, which has the advantages of high measurement accuracy, simple algorithm, and strong robustness. Comparison experiments with the current methods demonstrated that the investigated method can simultaneously accomplish the decoupling measurements of plane and space motions, which achieved the accuracy of 0.66% and 1.29% in the range of 0.1-2 Hz.