Yixiang Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yixiang Zhang has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Chang Sun
School of Instrument Science and Opto-electronics Engineering, Beihang University, Beijing, China
2 shared publications - Ming Ding
School of Instrumentation Science and Opto-Electronics Engineering, Beihang University, Beijing 100191, PR China
2 shared publications - Baicheng Xiao
School of Instrument Science and Opto-electronics Engineering, Beihang University, Beijing, China
1 shared publication - Bing Yan
School of Instrumentation and Optoelectronic Engineering Beihang University Beijing China
1 shared publication - Botao Wang
School of Instrument Science and Opto-electronics Engineering, Beihang University, Beijing, China
1 shared publication - Chao You
Department of Neurosurgery, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
1 shared publication
Latest Publications
Assessment of the utility of optically pumped magnetometer magnetoencephalography in preoperative localization of refractory epilepsy: A prospective study
Objective: Precise localization of the epileptogenic zone (EZ) is crucial for epilepsy surgery success. Optically pumped magnetometer magnetoencephalography (OPM‐MEG) is a promising noninvasive technique requiring rigorous clinical validation. Methods: In this prospective diagnostic study, 68 patients with refractory epilepsy underwent 90‐min interictal OPM‐MEG. Dipoles were fitted to interictal epileptiform discharges for localization. The primary objective was to evaluate the spatial concordance between OPM‐MEG and the EZ defined by intracranial electroencephalography (iEEG; stereo‐EEG or electrocorticography), assessed at the sublobar level using Gwet AC1. The secondary objective was to evaluate the diagnostic value of OPM‐MEG for surgical outcome. This analysis included 51 patients who underwent curative intervention (resection or thermocoagulation). The reference standard was a composite of the treated brain region and seizure freedom (International League Against Epilepsy [ILAE] class 1 or Engel class I) at ≥12‐month follow‐up, from which sensitivity, specificity, and diagnostic odds ratio (OR) were calculated. Results: OPM‐MEG showed almost perfect agreement with iEEG‐based EZ localization overall (AC1 = .885, concordance rate = 90.0%), with substantial agreement in temporal (80.1%, AC1 = .723) and almost perfect agreement in extratemporal regions (92.0%, AC1 = .926). The Euclidean centroid distance between OPM‐MEG and iEEG localizations was significantly shorter in concordant versus discordant cases. In the assessment of diagnostic value, OPM‐MEG demonstrated a sensitivity of 85.7% and specificity of 65.2% (OR = 11.25) under ILAE criteria, and a sensitivity of 73.0% and specificity of 64.3% (OR = 4.86) under Engel criteria. Significance: OPM‐MEG demonstrates high concordance with iEEG for EZ localization and provides robust diagnostic value for predicting postoperative seizure freedom, supporting its utility in the presurgical evaluation of refractory epilepsy.
Assessment of the utility of optically pumped magnetometer magnetoencephalography in preoperative localization of refractory epilepsy: A prospective study
Objective: Precise localization of the epileptogenic zone (EZ) is crucial for epilepsy surgery success. Optically pumped magnetometer magnetoencephalography (OPM‐MEG) is a promising noninvasive technique requiring rigorous clinical validation. Methods: In this prospective diagnostic study, 68 patients with refractory epilepsy underwent 90‐min interictal OPM‐MEG. Dipoles were fitted to interictal epileptiform discharges for localization. The primary objective was to evaluate the spatial concordance between OPM‐MEG and the EZ defined by intracranial electroencephalography (iEEG; stereo‐EEG or electrocorticography), assessed at the sublobar level using Gwet AC1. The secondary objective was to evaluate the diagnostic value of OPM‐MEG for surgical outcome. This analysis included 51 patients who underwent curative intervention (resection or thermocoagulation). The reference standard was a composite of the treated brain region and seizure freedom (International League Against Epilepsy [ILAE] class 1 or Engel class I) at ≥12‐month follow‐up, from which sensitivity, specificity, and diagnostic odds ratio (OR) were calculated. Results: OPM‐MEG showed almost perfect agreement with iEEG‐based EZ localization overall (AC1 = .885, concordance rate = 90.0%), with substantial agreement in temporal (80.1%, AC1 = .723) and almost perfect agreement in extratemporal regions (92.0%, AC1 = .926). The Euclidean centroid distance between OPM‐MEG and iEEG localizations was significantly shorter in concordant versus discordant cases. In the assessment of diagnostic value, OPM‐MEG demonstrated a sensitivity of 85.7% and specificity of 65.2% (OR = 11.25) under ILAE criteria, and a sensitivity of 73.0% and specificity of 64.3% (OR = 4.86) under Engel criteria. Significance: OPM‐MEG demonstrates high concordance with iEEG for EZ localization and provides robust diagnostic value for predicting postoperative seizure freedom, supporting its utility in the presurgical evaluation of refractory epilepsy.
- 16 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-8
Fiber Optic Array Temperature Field Measurement System for High-Temperature Turbine Blades
Turbine blades are the core components of aeroengines, and the measurement of the blade surface temperature field is a top priority in aeroengine design, development, and health monitoring. In this article, a fiber optic array temperature field measurement system for high-temperature turbine blades is proposed. First, a high-temperature resistant probe was designed by using sapphire fiber arrays. Then, an array temperature field measurement system was built based on the principle of colorimetric thermometry. Finally, temperature field measurement experiments of blades are conducted by building a high-temperature field rotor test rig. The experimental results show that the maximum temperature measurement error of the system is 0.96% in the temperature measurement range of 1400–2000 K, and according to the proposed temperature field reconstruction algorithm, the 3-D temperature field reconstruction of the blade is achieved.
- 16 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-8
Fiber Optic Array Temperature Field Measurement System for High-Temperature Turbine Blades
Turbine blades are the core components of aeroengines, and the measurement of the blade surface temperature field is a top priority in aeroengine design, development, and health monitoring. In this article, a fiber optic array temperature field measurement system for high-temperature turbine blades is proposed. First, a high-temperature resistant probe was designed by using sapphire fiber arrays. Then, an array temperature field measurement system was built based on the principle of colorimetric thermometry. Finally, temperature field measurement experiments of blades are conducted by building a high-temperature field rotor test rig. The experimental results show that the maximum temperature measurement error of the system is 0.96% in the temperature measurement range of 1400–2000 K, and according to the proposed temperature field reconstruction algorithm, the 3-D temperature field reconstruction of the blade is achieved.