Nikolay Nefediev
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nikolay Nefediev has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Nikolay Evgenievich Staroverov
Department of Electronic Instruments and Devices, Saint Petersburg Electrotechnical University "LETI", 197022 Saint Petersburg, Russia, Russia
5 shared publications - Roman V. Davydov
Higher School of Cyber-Physical Systems & Control, Peter the Great St. Petersburg Polytechnic University, 195251 St. Petersburg, Russia
4 shared publications - A. A. Pashkovskaya
Yudin Moscow State Clinical Hospital
1 shared publication - A. A. Ustalov
A.V. Vishnevsky National Medical Research Center of Surgery of the Ministry of Healthcare of the Russian Federation
1 shared publication - Alexander V. Govorov
Russian University of Medicine, Ministry of Health of Russia
1 shared publication - Alexandra V. Zharikova
A.V. Vishnevsky National Medical Research Center of Surgery of the Ministry of Healthcare of the Russian Federation
1 shared publication
Latest Publications
- Open Access
- 4 November 2026
- Published by MDPI AG in Preprints.org
Phase-Mixed Versus Phase-Specific Training for Pancreatic Lesion Segmentation on Contrast-Enhanced CT: A Non-Inferiority Study on PanTS
A model that segments pancreatic lesions from either arterial or portal venous CT could simplify deployment, provided that its performance is not inferior to that of phase-specific models. We evaluated nnU-Net ResEnc-M models trained on arterial scans (A), portal venous scans (P), or the combined dataset (M-full). Quality control, reconstruction of patient groups, and automatic phase assignment yielded 3,085 development scans and 438 held-out PanTS test scans. Five-fold cross-validation was repeated with three training seeds for A, P, and M-full; five reduced, phase-balanced training subsets were evaluated using seed 0. Non-inferiority required the lower confidence bound for the paired difference in lesion Dice to exceed −0.03. M-full met this criterion in both phases during cross-validation with all three seeds. On 85 lesion-positive portal test scans, its Dice advantage over P was 0.0387–0.0473, with all corresponding 95% confidence intervals above zero. M-full had fewer complete misses (17–19 versus 21–23 of 85), but more false-positive scans (34–39 versus 23–27 of 243 lesion-negative scans). Reducing the portal training subset lowered portal cross-validation performance in all five balanced variants. The arterial test contained only four positive scans and was therefore descriptive. Evaluation on 281 annotated Task07 scans was also descriptive because of known and unresolved dataset overlap. Mixed-phase training met the specified non-inferiority criterion while requiring only one CT volume at inference, but small-lesion misses and the false-positive trade-off remained.
- 4 November 2026
- Published by MDPI AG in Preprints.org
Open AccessPhase-Mixed Versus Phase-Specific Training for Pancreatic Lesion Segmentation on Contrast-Enhanced CT: A Non-Inferiority Study on PanTS
A model that segments pancreatic lesions from either arterial or portal venous CT could simplify deployment, provided that its performance is not inferior to that of phase-specific models. We evaluated nnU-Net ResEnc-M models trained on arterial scans (A), portal venous scans (P), or the combined dataset (M-full). Quality control, reconstruction of patient groups, and automatic phase assignment yielded 3,085 development scans and 438 held-out PanTS test scans. Five-fold cross-validation was repeated with three training seeds for A, P, and M-full; five reduced, phase-balanced training subsets were evaluated using seed 0. Non-inferiority required the lower confidence bound for the paired difference in lesion Dice to exceed −0.03. M-full met this criterion in both phases during cross-validation with all three seeds. On 85 lesion-positive portal test scans, its Dice advantage over P was 0.0387–0.0473, with all corresponding 95% confidence intervals above zero. M-full had fewer complete misses (17–19 versus 21–23 of 85), but more false-positive scans (34–39 versus 23–27 of 243 lesion-negative scans). Reducing the portal training subset lowered portal cross-validation performance in all five balanced variants. The arterial test contained only four positive scans and was therefore descriptive. Evaluation on 281 annotated Task07 scans was also descriptive because of known and unresolved dataset overlap. Mixed-phase training met the specified non-inferiority criterion while requiring only one CT volume at inference, but small-lesion misses and the false-positive trade-off remained.
- 14 September 2026
- Published by Pleiades Publishing Ltd in Bulletin of the Russian Academy of Sciences: Physics
- Vol. 90 (9) , 1531-1538
Application of Convolutional Neural Networks to Improve Tumor Segmentation in Prostate MRI
The study aims to obtain segmentations (masks) of areas with prostate cancer in MRI studies of the pelvic organs in men. Various neural network architectures for 2D and 3D segmentation in MRI series were examined, as well as methods for improving results of prostate presegmentation using a classification neural network. Methods for improving prostate segmentation were also considered.
- 14 September 2026
- Published by Pleiades Publishing Ltd in Bulletin of the Russian Academy of Sciences: Physics
- Vol. 90 (9) , 1531-1538
Application of Convolutional Neural Networks to Improve Tumor Segmentation in Prostate MRI
The study aims to obtain segmentations (masks) of areas with prostate cancer in MRI studies of the pelvic organs in men. Various neural network architectures for 2D and 3D segmentation in MRI series were examined, as well as methods for improving results of prostate presegmentation using a classification neural network. Methods for improving prostate segmentation were also considered.
- Open Access
- 29 January 2026
- Published by Baltic Medical Education Center in Diagnostic radiology and radiotherapy
- Vol. 16 (4)
The possibilities of artificial intelligence in detecting prostate cancer according to magnetic resonance imaging: intermediate indicators of the effectiveness of the national second opinion system
Introduction: The use of deep learning in the detection of prostate cancer (PCa) based on multiparametric MRI (mpMRI) data is one of the most controversial areas of development of this technology in medicine. Despite high international interest in such systems, the number of thematic studies in the Russian Federation remains limited. Objective: To describe the process of creating and validating a domestic medical decision support system (MDSS) designed to diagnose PCa based on mpMRI results using AI. Materials and methods: Data on patients with a confirmed diagnosis who underwent radical prostatectomy were collected both retrospectively and prospectively. The patient sample was formed between January 10, 2023 and May 1, 2025. T2- weighted images (T2-WI) and measured diffusion coefficient (MDC) data were used as working sequences. Data annotation was performed manually by three specialists with more than 10 years of experience in independently performing and analyzing MR data of patients with suspected PCa. During the study, four different architectures were tested to evaluate their effectiveness and determine the most suitable one for the tasks at hand. The following metrics were used to measure accuracy: sensitivity, specificity, accuracy, area under the ROC curve (AUC), and Dice score (DSC). Results: In accordance with the inclusion criteria, 441 studies performed on 19 different MRI scanners were collected. Validation of the most productive neural network architecture revealed the following indicators: accuracy — 73%, sensitivity — 71%, specificity — 71%, AUC — 0.70, DSC — 0.70. Discussion: The work presented by us is aimed at familiarizing specialists with the intermediate results of the development of the first national MDSS, implemented according to a strategy of avoiding the shortcomings present in the works of other teams. Conclusion: The results of testing the developed AI-based program for the detection and reconstruction of PCa on MRI images showed promising prospects for the domestic medical decision support system. To confirm the clinical applicability and effectiveness of the developed program, further multicenter studies are needed to assess its potential and feasibility for implementation in real clinical practice.
- 29 January 2026
- Published by Baltic Medical Education Center in Diagnostic radiology and radiotherapy
- Vol. 16 (4)
Open AccessThe possibilities of artificial intelligence in detecting prostate cancer according to magnetic resonance imaging: intermediate indicators of the effectiveness of the national second opinion system
Introduction: The use of deep learning in the detection of prostate cancer (PCa) based on multiparametric MRI (mpMRI) data is one of the most controversial areas of development of this technology in medicine. Despite high international interest in such systems, the number of thematic studies in the Russian Federation remains limited. Objective: To describe the process of creating and validating a domestic medical decision support system (MDSS) designed to diagnose PCa based on mpMRI results using AI. Materials and methods: Data on patients with a confirmed diagnosis who underwent radical prostatectomy were collected both retrospectively and prospectively. The patient sample was formed between January 10, 2023 and May 1, 2025. T2- weighted images (T2-WI) and measured diffusion coefficient (MDC) data were used as working sequences. Data annotation was performed manually by three specialists with more than 10 years of experience in independently performing and analyzing MR data of patients with suspected PCa. During the study, four different architectures were tested to evaluate their effectiveness and determine the most suitable one for the tasks at hand. The following metrics were used to measure accuracy: sensitivity, specificity, accuracy, area under the ROC curve (AUC), and Dice score (DSC). Results: In accordance with the inclusion criteria, 441 studies performed on 19 different MRI scanners were collected. Validation of the most productive neural network architecture revealed the following indicators: accuracy — 73%, sensitivity — 71%, specificity — 71%, AUC — 0.70, DSC — 0.70. Discussion: The work presented by us is aimed at familiarizing specialists with the intermediate results of the development of the first national MDSS, implemented according to a strategy of avoiding the shortcomings present in the works of other teams. Conclusion: The results of testing the developed AI-based program for the detection and reconstruction of PCa on MRI images showed promising prospects for the domestic medical decision support system. To confirm the clinical applicability and effectiveness of the developed program, further multicenter studies are needed to assess its potential and feasibility for implementation in real clinical practice.
- Top Cited PapersOpen Access
- 19 January 2026
- Published by MDPI AG in Algorithms
- Vol. 19 (1) , 85
Improving Prostate Cancer Segmentation on T2-Weighted MRI Using Prostate Detection and Cascaded Networks
Prostate cancer is one of the most lethal cancers in the male population, and accurate localization of intraprostatic lesions on MRI remains challenging. In this study, we investigated methods for improving prostate cancer segmentation on T2-weighted pelvic MRI using cascaded neural networks. We used an anonymized dataset of 400 multiparametric MRI scans from two centers, in which experienced radiologists had delineated the prostate and clinically significant cancer on the T2 series. Our baseline approach applies 2D and 3D segmentation networks (UNETR, UNET++, Swin-UNETR, SegResNetDS, and SegResNetVAE) directly to full MRI volumes. We then introduce additional stages that filter slices using DenseNet-201 classifiers (cancer/no-cancer and prostate/no-prostate) and localize the prostate via a YOLO-based detector to crop the 3D region of interest before segmentation. Using Swin-UNETR as the backbone, the prostate segmentation Dice score increased from 71.37% for direct 3D segmentation to 76.09% when using prostate detection and cropped 3D inputs. For cancer segmentation, the final cascaded pipeline—prostate detection, 3D prostate segmentation, and 3D cancer segmentation within the prostate—improved the Dice score from 55.03% for direct 3D segmentation to 67.11%, with an ROC AUC of 0.89 on the test set. These results suggest that cascaded detection- and segmentation-based preprocessing of the prostate region can substantially improve automatic prostate cancer segmentation on MRI while remaining compatible with standard segmentation architectures.
- 19 January 2026
- Published by MDPI AG in Algorithms
- Vol. 19 (1) , 85
Top Cited PapersOpen AccessImproving Prostate Cancer Segmentation on T2-Weighted MRI Using Prostate Detection and Cascaded Networks
Prostate cancer is one of the most lethal cancers in the male population, and accurate localization of intraprostatic lesions on MRI remains challenging. In this study, we investigated methods for improving prostate cancer segmentation on T2-weighted pelvic MRI using cascaded neural networks. We used an anonymized dataset of 400 multiparametric MRI scans from two centers, in which experienced radiologists had delineated the prostate and clinically significant cancer on the T2 series. Our baseline approach applies 2D and 3D segmentation networks (UNETR, UNET++, Swin-UNETR, SegResNetDS, and SegResNetVAE) directly to full MRI volumes. We then introduce additional stages that filter slices using DenseNet-201 classifiers (cancer/no-cancer and prostate/no-prostate) and localize the prostate via a YOLO-based detector to crop the 3D region of interest before segmentation. Using Swin-UNETR as the backbone, the prostate segmentation Dice score increased from 71.37% for direct 3D segmentation to 76.09% when using prostate detection and cropped 3D inputs. For cancer segmentation, the final cascaded pipeline—prostate detection, 3D prostate segmentation, and 3D cancer segmentation within the prostate—improved the Dice score from 55.03% for direct 3D segmentation to 67.11%, with an ROC AUC of 0.89 on the test set. These results suggest that cascaded detection- and segmentation-based preprocessing of the prostate region can substantially improve automatic prostate cancer segmentation on MRI while remaining compatible with standard segmentation architectures.
- Open Access
- 22 December 2025
- Published by MDPI AG in Preprints.org
Improving Prostate Cancer Segmentation on T2-Weighted MRI Using Prostate Detection and Cascaded Networks
Prostate cancer is one of the most lethal cancers in the male population, and accurate localization of intraprostatic lesions on MRI remains challenging. In this work, we investigate methods for improving prostate cancer segmentation on T2weighted pelvic MRI using cascaded neural networks. We use anonymized dataset of 400 multiparametric MRI studies from two centers, in which experienced radiologists delineated the prostate and clinically significant cancer on the T2 series. Our baseline approach applies 2D and 3D segmentation networks (UNETR, UNET++, SwinUNETR, SegResNetDS, SegResNetVAE) directly to full MRI volumes. We then introduce additional stages that filter slices using DenseNet201 classifiers (cancer/nocancer and prostate/noprostate) and localize the prostate with a YOLObased detector to crop a 3D region of interest before segmentation. Using SwinUNETR as the backbone, the prostate segmentation Dice score increased from 71.37% for direct 3D segmentation to 76.09% when using prostate detection and cropped 3D inputs. For cancer segmentation, the final cascaded pipeline – prostate detection, 3D prostate segmentation, and 3D cancer segmentation within the prostate – improved Dice score from 55.03% for direct 3D segmentation to 67.11%, with a ROC AUC of 0.89 on the test set. These results suggest that cascaded detection and segmentationbased preprocessing of the prostate region can substantially improve automatic prostate cancer segmentation on MRI while remaining compatible with standard segmentation architectures.
- 22 December 2025
- Published by MDPI AG in Preprints.org
Open AccessImproving Prostate Cancer Segmentation on T2-Weighted MRI Using Prostate Detection and Cascaded Networks
Prostate cancer is one of the most lethal cancers in the male population, and accurate localization of intraprostatic lesions on MRI remains challenging. In this work, we investigate methods for improving prostate cancer segmentation on T2weighted pelvic MRI using cascaded neural networks. We use anonymized dataset of 400 multiparametric MRI studies from two centers, in which experienced radiologists delineated the prostate and clinically significant cancer on the T2 series. Our baseline approach applies 2D and 3D segmentation networks (UNETR, UNET++, SwinUNETR, SegResNetDS, SegResNetVAE) directly to full MRI volumes. We then introduce additional stages that filter slices using DenseNet201 classifiers (cancer/nocancer and prostate/noprostate) and localize the prostate with a YOLObased detector to crop a 3D region of interest before segmentation. Using SwinUNETR as the backbone, the prostate segmentation Dice score increased from 71.37% for direct 3D segmentation to 76.09% when using prostate detection and cropped 3D inputs. For cancer segmentation, the final cascaded pipeline – prostate detection, 3D prostate segmentation, and 3D cancer segmentation within the prostate – improved Dice score from 55.03% for direct 3D segmentation to 67.11%, with a ROC AUC of 0.89 on the test set. These results suggest that cascaded detection and segmentationbased preprocessing of the prostate region can substantially improve automatic prostate cancer segmentation on MRI while remaining compatible with standard segmentation architectures.
- Open Access
- 7 August 2024
- Published by Vidar, Ltd. in Medical Visualization
- Vol. 28 (3) , 12-21
Deep Machine Learning for Automatic Segmentation of the Pancreatic Parenchyma and its hypo- and hypervascular lesions on CT Images
Objective of the study. To develop and evaluate the effectiveness of a technology for segmenting the pancreatic parenchyma and its hyper- and hypovascular lesions on abdominal computed tomography (CT) scans using deep machine learning. Materials and methods. CT scans from the database of the A.V. Vishnevsky National Medical Research Center of Surgery were used for training and testing the algorithms – a total number of approximately 150 studies (arterial and venous phases). A test dataset of 46 anonymized CT scans (arterial and venous phases) was prepared for validation of the obtained algorithms, independently assessed by expert physicians. The primary segmentation neural network used is nn-UNet (M. Antonelli et al., 2022). Results . The average accuracy of the test dataset for the model determining segmentation masks of the pancreas on CT images had an AUC of 0.8 for the venous phase and 0.85 for the arterial phase. The segmentation masks of pancreatic formations had an AUC of 0.6. Conclusion. Automated segmentation of the pancreatic parenchyma structure using deep machine learning technologies demonstrated high accuracy. However, the segmentation of hypo- and hypervascular pancreatic lesions requires improvement. The overlap of the masks showed a rather low result, but in all cases, the location of the pathological formation was correctly identified by the algorithm. Enhancing the training dataset and the algorithm used could increase the accuracy of the algorithm. No false negative results were obtained when detecting pancreatic formations; in all cases, the INS detected “suspicious” areas of the pancreatic parenchyma. This can help reduce the omission of pancreatic pathologies in CT scans, and their further assessment can be carried out by the radiologist himself.
- 7 August 2024
- Published by Vidar, Ltd. in Medical Visualization
- Vol. 28 (3) , 12-21
Open AccessDeep Machine Learning for Automatic Segmentation of the Pancreatic Parenchyma and its hypo- and hypervascular lesions on CT Images
Objective of the study. To develop and evaluate the effectiveness of a technology for segmenting the pancreatic parenchyma and its hyper- and hypovascular lesions on abdominal computed tomography (CT) scans using deep machine learning. Materials and methods. CT scans from the database of the A.V. Vishnevsky National Medical Research Center of Surgery were used for training and testing the algorithms – a total number of approximately 150 studies (arterial and venous phases). A test dataset of 46 anonymized CT scans (arterial and venous phases) was prepared for validation of the obtained algorithms, independently assessed by expert physicians. The primary segmentation neural network used is nn-UNet (M. Antonelli et al., 2022). Results . The average accuracy of the test dataset for the model determining segmentation masks of the pancreas on CT images had an AUC of 0.8 for the venous phase and 0.85 for the arterial phase. The segmentation masks of pancreatic formations had an AUC of 0.6. Conclusion. Automated segmentation of the pancreatic parenchyma structure using deep machine learning technologies demonstrated high accuracy. However, the segmentation of hypo- and hypervascular pancreatic lesions requires improvement. The overlap of the masks showed a rather low result, but in all cases, the location of the pathological formation was correctly identified by the algorithm. Enhancing the training dataset and the algorithm used could increase the accuracy of the algorithm. No false negative results were obtained when detecting pancreatic formations; in all cases, the INS detected “suspicious” areas of the pancreatic parenchyma. This can help reduce the omission of pancreatic pathologies in CT scans, and their further assessment can be carried out by the radiologist himself.