Josephine Olsen Kipp
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Josephine Olsen Kipp has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Maiken Stilling
Aarhus University Hospital
8 shared publications Emil Toft Petersen
AutoRSA Research Group, Orthopaedic Research Unit Aarhus University Hospital Aarhus Denmark
5 shared publicationsTheis Muncholm Thillemann
Department of Orthopaedic Surgery Aarhus University Hospital Aarhus Denmark
5 shared publicationsMaiken Stilling
AutoRSA Research Group, Orthopaedic Research Unit Aarhus University Hospital Aarhus Denmark
4 shared publications- Mats Bue
Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
4 shared publications Rikke Jellesen Åberg
Department of Radiology Aarhus University Hospital Aarhus Denmark
4 shared publications
Latest Publications
- Open Access
- 11 October 2026
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 13 (4) , e70930
Restoration of shoulder kinematics during active throwing after the Latarjet procedure in anterior shoulder instability: A dynamic radiostereometric study
Purpose: To evaluate glenohumeral joint (GHJ) kinematics during a throwing motion in patients with anterior shoulder instability before and 1 year after the Latarjet procedure. Methods: In this prospective study, 13 patients with unilateral, traumatic anterior shoulder instability scheduled for the Latarjet procedure were examined preoperatively and at 1‐year follow‐up. GHJ kinematics were assessed during a standardized throwing motion using dynamic radiostereometric analysis. Preoperatively, both the injured and contralateral healthy shoulders were assessed. One year post‐operatively, only the injured shoulder was assessed. GHJ kinematics were evaluated in six degrees of freedom, including rotations and translations of the humeral head centre and contact point, as well as the glenohumeral contact area, throughout the throwing motion. Results: Post‐operatively, the humeral head centre shifted up to 1.1 mm posteriorly (95% confidence interval [CI]: 0.3–1.9) and 0.4 mm superiorly (95% CI: 0.0–0.7) compared with the injured shoulder and was 1.4 mm (95% CI: −1.2 to 4.1) more posterior compared with the healthy shoulder. The contact point translations showed similar patterns, although not statistically significant. The GHJ contact area increased post‐operatively by up to 87.0 mm 2 (95% CI: 35.9–138.0) compared with the injured shoulder and with no statistically significant difference compared with the healthy shoulder. Conclusions: The Latarjet procedure produced a posterior–superior shift of the humeral head compared with the preoperative injured shoulder and restored glenohumeral contact area to levels similar to the healthy shoulder during an active throwing motion. These findings support the stabilizing effect of Latarjet procedures under functional, load‐bearing conditions relevant to overhead athletes. Level of Evidence: Level III.
- 11 October 2026
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 13 (4) , e70930
Open AccessRestoration of shoulder kinematics during active throwing after the Latarjet procedure in anterior shoulder instability: A dynamic radiostereometric study
Purpose: To evaluate glenohumeral joint (GHJ) kinematics during a throwing motion in patients with anterior shoulder instability before and 1 year after the Latarjet procedure. Methods: In this prospective study, 13 patients with unilateral, traumatic anterior shoulder instability scheduled for the Latarjet procedure were examined preoperatively and at 1‐year follow‐up. GHJ kinematics were assessed during a standardized throwing motion using dynamic radiostereometric analysis. Preoperatively, both the injured and contralateral healthy shoulders were assessed. One year post‐operatively, only the injured shoulder was assessed. GHJ kinematics were evaluated in six degrees of freedom, including rotations and translations of the humeral head centre and contact point, as well as the glenohumeral contact area, throughout the throwing motion. Results: Post‐operatively, the humeral head centre shifted up to 1.1 mm posteriorly (95% confidence interval [CI]: 0.3–1.9) and 0.4 mm superiorly (95% CI: 0.0–0.7) compared with the injured shoulder and was 1.4 mm (95% CI: −1.2 to 4.1) more posterior compared with the healthy shoulder. The contact point translations showed similar patterns, although not statistically significant. The GHJ contact area increased post‐operatively by up to 87.0 mm 2 (95% CI: 35.9–138.0) compared with the injured shoulder and with no statistically significant difference compared with the healthy shoulder. Conclusions: The Latarjet procedure produced a posterior–superior shift of the humeral head compared with the preoperative injured shoulder and restored glenohumeral contact area to levels similar to the healthy shoulder during an active throwing motion. These findings support the stabilizing effect of Latarjet procedures under functional, load‐bearing conditions relevant to overhead athletes. Level of Evidence: Level III.
- Open Access
- 9 August 2026
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 44 (8) , e70258
Glenohumeral Stability During External Rotation in Patients Treated With the Latarjet Procedure: A Two‐Year Dynamic Radiostereometric Study
The Latarjet procedure is widely used for anterior shoulder instability with glenoid bone loss, yet its influence on glenohumeral joint (GHJ) kinematics during functional movement remains unclear. This study evaluated GHJ kinematics during active external rotation compared with the contralateral shoulder preoperatively and at 1‐ and 2‐year follow‐up using dynamic radiostereometry (RSA) and CT‐derived 3D bone models registered to the radiographs. Patient‐reported outcomes were assessed using the Western Ontario Shoulder Instability Index (WOSI). Preoperatively, the injured shoulder showed a tendency toward a more anterior (up to 1.5 mm, CI −0.3–3.3) and inferior (up to 1.1 mm, CI −0.3–2.5) humeral head position. At 1 year postoperatively, the humeral head was more posterior (up to 1.8 mm, CI 0.8–2.9) and superior (4.0 mm, CI −4.1–12.1) compared with preoperatively, with an additional posterior shift at 2 years (1.5 mm, CI 0.4–2.6). Postoperative kinematics did not differ from the healthy shoulder. Contact area decreased preoperatively by up to 121.7 mm 2 (CI 57.1–186.3) and increased by up to 110.8 mm 2 (CI 42.3–179.3) at 2 years. WOSI improved from 55% (CI 49–61) preoperatively to 36% (CI 25–48) at 1 year and 27% (CI 17–36) at 2 years. The Latarjet procedure resulted in GHJ kinematics comparable to the healthy shoulder during external rotation. Postoperatively, kinematics shifted posteriorly and superiorly with improved WOSI scores over 2 years. Clinical Significance: Near‐normal GHJ kinematics during external rotation are achieved within 2 years, supporting improved shoulder function in anterior instability following the Latarjet procedure.
- 9 August 2026
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 44 (8) , e70258
Open AccessGlenohumeral Stability During External Rotation in Patients Treated With the Latarjet Procedure: A Two‐Year Dynamic Radiostereometric Study
The Latarjet procedure is widely used for anterior shoulder instability with glenoid bone loss, yet its influence on glenohumeral joint (GHJ) kinematics during functional movement remains unclear. This study evaluated GHJ kinematics during active external rotation compared with the contralateral shoulder preoperatively and at 1‐ and 2‐year follow‐up using dynamic radiostereometry (RSA) and CT‐derived 3D bone models registered to the radiographs. Patient‐reported outcomes were assessed using the Western Ontario Shoulder Instability Index (WOSI). Preoperatively, the injured shoulder showed a tendency toward a more anterior (up to 1.5 mm, CI −0.3–3.3) and inferior (up to 1.1 mm, CI −0.3–2.5) humeral head position. At 1 year postoperatively, the humeral head was more posterior (up to 1.8 mm, CI 0.8–2.9) and superior (4.0 mm, CI −4.1–12.1) compared with preoperatively, with an additional posterior shift at 2 years (1.5 mm, CI 0.4–2.6). Postoperative kinematics did not differ from the healthy shoulder. Contact area decreased preoperatively by up to 121.7 mm 2 (CI 57.1–186.3) and increased by up to 110.8 mm 2 (CI 42.3–179.3) at 2 years. WOSI improved from 55% (CI 49–61) preoperatively to 36% (CI 25–48) at 1 year and 27% (CI 17–36) at 2 years. The Latarjet procedure resulted in GHJ kinematics comparable to the healthy shoulder during external rotation. Postoperatively, kinematics shifted posteriorly and superiorly with improved WOSI scores over 2 years. Clinical Significance: Near‐normal GHJ kinematics during external rotation are achieved within 2 years, supporting improved shoulder function in anterior instability following the Latarjet procedure.
- Open Access
- 10 April 2026
- Published by Elsevier in Clinical Biomechanics
- Vol. 137, 106847
Daily shoulder activity in patients with anterior shoulder instability before and after shoulder stabilizing surgery measured with inertial measurement units
- 10 April 2026
- Published by Elsevier in Clinical Biomechanics
- Vol. 137, 106847
Open AccessDaily shoulder activity in patients with anterior shoulder instability before and after shoulder stabilizing surgery measured with inertial measurement units
- 3 November 2025
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 107 (23) , 2661-2670
The Latarjet Procedure May Induce Pathokinematics with Posterior Humeral Head Subluxation
Background: The effectiveness of the Latarjet procedure in stabilizing the glenohumeral joint (GHJ) in the abducted and externally rotated position is well documented. However, evidence of its ability to restore the GHJ kinematics in other positions and without anterior-directed load is sparse. The purpose of this study was to evaluate the GHJ kinematics, throughout external rotation, following the Latarjet procedure in shoulders with 15% anterior glenoid bone loss. Methods: Eight human donor arms were examined using dynamic radiostereometry during GHJ external rotation with anterior-directed loads of 0 to 30 N. Kinematics, measured on the basis of the humeral head center and the contact point relative to the glenoid, were assessed at 30° and 60° of GHJ abduction for 3 conditions: the native GHJ, 15% glenoid bone loss, and following the Latarjet procedure. Results: Following the Latarjet procedure, the humeral head center and contact point were up to 9.7 mm (95% confidence interval [CI], 0.5 to 18.8 mm) more posterior and 7.4 mm (95% CI, 0.3 to 14.4 mm) more superior compared with 15% glenoid bone loss. With a 30 N anterior-directed load, the contact point was up to 4.4 mm (95% CI, 2.4 to 6.4 mm) more anterior compared with 15% glenoid bone loss. No significant differences in kinematics between the native GHJ and following the Latarjet procedure were observed with anterior-directed load application. However, without an anterior-directed load, the humeral head center and contact point were up to 7.9 mm (95% CI, 2.3 to 13.5 mm) more posterior and 6.1 mm (95% CI, 0.0 to 12.2 mm) more inferior following the Latarjet procedure compared with the native GHJ. Conclusions: With anterior-directed loading, the Latarjet procedure to treat 15% glenoid bone loss restored the native GHJ kinematics, with the largest stabilizing effect at the end-range external rotation. However, without anterior-directed loading, the humeral head center and contact point were more posterior and inferior following the Latarjet procedure than in the native GHJ, suggesting potential excessive posterior humeral head translation. Clinical Relevance: Posterior subluxation of the humeral head during resting and non-loaded activities following the Latarjet procedure may be a concern in terms of future posterior glenoid cartilage wear and GHJ osteoarthritis. However, these results need to be confirmed in a clinical setting.
- 3 November 2025
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 107 (23) , 2661-2670
The Latarjet Procedure May Induce Pathokinematics with Posterior Humeral Head Subluxation
Background: The effectiveness of the Latarjet procedure in stabilizing the glenohumeral joint (GHJ) in the abducted and externally rotated position is well documented. However, evidence of its ability to restore the GHJ kinematics in other positions and without anterior-directed load is sparse. The purpose of this study was to evaluate the GHJ kinematics, throughout external rotation, following the Latarjet procedure in shoulders with 15% anterior glenoid bone loss. Methods: Eight human donor arms were examined using dynamic radiostereometry during GHJ external rotation with anterior-directed loads of 0 to 30 N. Kinematics, measured on the basis of the humeral head center and the contact point relative to the glenoid, were assessed at 30° and 60° of GHJ abduction for 3 conditions: the native GHJ, 15% glenoid bone loss, and following the Latarjet procedure. Results: Following the Latarjet procedure, the humeral head center and contact point were up to 9.7 mm (95% confidence interval [CI], 0.5 to 18.8 mm) more posterior and 7.4 mm (95% CI, 0.3 to 14.4 mm) more superior compared with 15% glenoid bone loss. With a 30 N anterior-directed load, the contact point was up to 4.4 mm (95% CI, 2.4 to 6.4 mm) more anterior compared with 15% glenoid bone loss. No significant differences in kinematics between the native GHJ and following the Latarjet procedure were observed with anterior-directed load application. However, without an anterior-directed load, the humeral head center and contact point were up to 7.9 mm (95% CI, 2.3 to 13.5 mm) more posterior and 6.1 mm (95% CI, 0.0 to 12.2 mm) more inferior following the Latarjet procedure compared with the native GHJ. Conclusions: With anterior-directed loading, the Latarjet procedure to treat 15% glenoid bone loss restored the native GHJ kinematics, with the largest stabilizing effect at the end-range external rotation. However, without anterior-directed loading, the humeral head center and contact point were more posterior and inferior following the Latarjet procedure than in the native GHJ, suggesting potential excessive posterior humeral head translation. Clinical Relevance: Posterior subluxation of the humeral head during resting and non-loaded activities following the Latarjet procedure may be a concern in terms of future posterior glenoid cartilage wear and GHJ osteoarthritis. However, these results need to be confirmed in a clinical setting.
- Open Access
- 3 June 2025
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Research
- Vol. 14 (6) , 506-515
One-year follow-up of 20 patients undergoing the Latarjet procedure
Aims: The Latarjet procedure is the treatment of choice for patients who have recurrent anterior shoulder instability with glenoid bone loss. However, the stabilizing effect of the Latarjet procedure in patients is sparsely described. The aim of this study was to evaluate the glenohumeral joint (GHJ) kinematics during an apprehension-relocation test in patients with anterior shoulder instability before and after their Latarjet procedure, and in comparison with their contralateral healthy shoulder.Methods: A total of 20 patients scheduled for the Latarjet procedure were enrolled. The patients were examined preoperatively with bilateral radiostereometric analysis (RSA) and one year after surgery on the operated shoulder with an apprehension-relocation test. Bone models were obtained from CT scans and aligned with the RSA images. The GHJ kinematics was evaluated with two methods: the humeral head centre location relative to the glenoid centre, and the GHJ contact point relative to the glenoid centre.Results: No difference in GHJ kinematics was found between the healthy and the postoperative GHJ. Compared with the preoperative injured shoulder, the postoperative mean (95% CI) humeral head centre was 0.8 mm (0.1 to 1.4) more superior and 0.7 mm (-0.1. to 1.4) more posterior during the apprehension test, and 0.5 mm (0.0 to 1.1) more posterior during the relocation test. The postoperative contact point was posterior to the coracoid bone block and 0.9 mm (-0.2 to 2.0) more posterior than in the preoperative injured shoulder during the apprehension test. The articulating area of the coracoid bone block was decreased by 63.9% (75.5 to 114.6) one year after surgery.Conclusion: The Latarjet procedure restored the humeral head centre location posterior and superior, and the contact point posterior, to the coracoid bone block. This suggests that the stabilizing effect of the GHJ following the Latarjet procedure is primarily due to the conjoined tendon rather than the coracoid bone block itself.Cite this article: Bone Joint Res 2025;14(6):506–515.
- 3 June 2025
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Research
- Vol. 14 (6) , 506-515
Open AccessOne-year follow-up of 20 patients undergoing the Latarjet procedure
Aims: The Latarjet procedure is the treatment of choice for patients who have recurrent anterior shoulder instability with glenoid bone loss. However, the stabilizing effect of the Latarjet procedure in patients is sparsely described. The aim of this study was to evaluate the glenohumeral joint (GHJ) kinematics during an apprehension-relocation test in patients with anterior shoulder instability before and after their Latarjet procedure, and in comparison with their contralateral healthy shoulder.Methods: A total of 20 patients scheduled for the Latarjet procedure were enrolled. The patients were examined preoperatively with bilateral radiostereometric analysis (RSA) and one year after surgery on the operated shoulder with an apprehension-relocation test. Bone models were obtained from CT scans and aligned with the RSA images. The GHJ kinematics was evaluated with two methods: the humeral head centre location relative to the glenoid centre, and the GHJ contact point relative to the glenoid centre.Results: No difference in GHJ kinematics was found between the healthy and the postoperative GHJ. Compared with the preoperative injured shoulder, the postoperative mean (95% CI) humeral head centre was 0.8 mm (0.1 to 1.4) more superior and 0.7 mm (-0.1. to 1.4) more posterior during the apprehension test, and 0.5 mm (0.0 to 1.1) more posterior during the relocation test. The postoperative contact point was posterior to the coracoid bone block and 0.9 mm (-0.2 to 2.0) more posterior than in the preoperative injured shoulder during the apprehension test. The articulating area of the coracoid bone block was decreased by 63.9% (75.5 to 114.6) one year after surgery.Conclusion: The Latarjet procedure restored the humeral head centre location posterior and superior, and the contact point posterior, to the coracoid bone block. This suggests that the stabilizing effect of the GHJ following the Latarjet procedure is primarily due to the conjoined tendon rather than the coracoid bone block itself.Cite this article: Bone Joint Res 2025;14(6):506–515.
- 24 December 2024
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 43 (3) , 492-504
Evaluation of Glenohumeral Joint Kinematics Following the Latarjet and Eden‐Hybinette Procedures a Dynamic Radiostereometric Cadaver Study
Anterior shoulder instability with glenoid bone lesion can be treated with the Eden‐Hybinette procedure utilizing a tricortical iliac crest bone graft or the Latarjet procedure. This study aimed to evaluate the glenohumeral joint (GHJ) kinematics throughout an external shoulder rotation following the Eden‐Hybinette and Latarjet procedures. Nine human specimens were examined with dynamic radiostereometry during a GHJ external rotation with anteriorly directed loads from 0 to 30 N. In 30‐ and 60‐degree GHJ abduction, the kinematics (measured as the humeral head center and contact point) was sequentially recorded for a 15% anterior glenoid bone lesion, the Eden‐Hybinette, and the Latarjet procedure. The Latarjet and Eden‐Hybinette procedures resulted in up to 9.7 mm (95%CI 0.5; 18.8) more posterior and a 7.4 mm (95%CI 0.3; 14.4) superior humeral head center location compared to the glenoid bone lesion. With 0–20 N anterior directed loads, the Latarjet procedure resulted in a more posterior humeral head center and contact point of up to 7.6 mm (95%CI 3.6; 11.5), especially in 60 degrees of GHJ abduction, compared to the Eden‐Hybinette procedure. Opposite, at 30 N anterior‐directed load, the Eden‐Hybinette procedure resulted in a more posterior humeral head center of up to 7.6 mm (95%CI 0.3; 14.9) in 30 degrees GHJ abduction compared to the Latarjet procedure. The results support considering the Latarjet procedures in patients who need the stabilizing effect with the arm in the abducted and externally rotated position (e.g., throwers) and the Eden‐Hybinette procedure in patients exposed to high anterior‐directed loads with the arm at lower abduction angles (e.g., epilepsia).
- 24 December 2024
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 43 (3) , 492-504
Evaluation of Glenohumeral Joint Kinematics Following the Latarjet and Eden‐Hybinette Procedures a Dynamic Radiostereometric Cadaver Study
Anterior shoulder instability with glenoid bone lesion can be treated with the Eden‐Hybinette procedure utilizing a tricortical iliac crest bone graft or the Latarjet procedure. This study aimed to evaluate the glenohumeral joint (GHJ) kinematics throughout an external shoulder rotation following the Eden‐Hybinette and Latarjet procedures. Nine human specimens were examined with dynamic radiostereometry during a GHJ external rotation with anteriorly directed loads from 0 to 30 N. In 30‐ and 60‐degree GHJ abduction, the kinematics (measured as the humeral head center and contact point) was sequentially recorded for a 15% anterior glenoid bone lesion, the Eden‐Hybinette, and the Latarjet procedure. The Latarjet and Eden‐Hybinette procedures resulted in up to 9.7 mm (95%CI 0.5; 18.8) more posterior and a 7.4 mm (95%CI 0.3; 14.4) superior humeral head center location compared to the glenoid bone lesion. With 0–20 N anterior directed loads, the Latarjet procedure resulted in a more posterior humeral head center and contact point of up to 7.6 mm (95%CI 3.6; 11.5), especially in 60 degrees of GHJ abduction, compared to the Eden‐Hybinette procedure. Opposite, at 30 N anterior‐directed load, the Eden‐Hybinette procedure resulted in a more posterior humeral head center of up to 7.6 mm (95%CI 0.3; 14.9) in 30 degrees GHJ abduction compared to the Latarjet procedure. The results support considering the Latarjet procedures in patients who need the stabilizing effect with the arm in the abducted and externally rotated position (e.g., throwers) and the Eden‐Hybinette procedure in patients exposed to high anterior‐directed loads with the arm at lower abduction angles (e.g., epilepsia).
- Open Access
- 26 October 2024
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 11 (4) , e70065
Short arm splints for wrist stabilization: A mechanical material test and cadaveric radiography study
Purpose: Documentation of the wrist stabilizing effect and mechanical properties of common splinting materials is warranted to support evidence‐based condition‐specific recommendations for wrist immobilization. The objectives of this study were to assess the wrist stabilizing properties of volar and dorsal short‐arm splints made of four different materials and evaluate the mechanical properties of the splinting materials.Methods: Dorsal and volar short arm splints made of plaster of Paris (PoP) (eight layers), Woodcast (2 mm, rigid vented), X‐lite (classic, two layers) or a 3D‐printed material (polypropylene) were sequentially mounted on 10 cadaveric arm specimens and fixed in a radiolucent fixture. This enabled the evaluation of maximum wrist flexion and extension relative under an orthogonal load of 42 N via radiographic images. In addition, a three‐point bending test was performed on ten sheet duplicates of each of the four splinting materials.Results: When applied as a volar splint, PoP had the highest capability to resist wrist flexion and extension. However, when applied as a dorsal splint, Woodcast exhibited a lower wrist flexion and a similar wrist extension. The 3D‐printed splints—both volar and dorsal—showed the highest mean wrist flexion and extension. The mechanical properties of the Woodcast, X‐lite and 3D‐printed splinting materials were very similar. PoP exhibited distinct properties with a stiffness of 146 (95% confidence interval [CI]: 120–173) N/mm and a deflection at Fmax of 0.6 (95% CI: 0.5–0.7) mm compared to ≤7.7 (95% CI: 7.4–7.9) N/mm and ≥20 (95% CI: 18–22) mm for the other materials.Conclusion: PoP displayed better wrist stabilizing properties and material stiffness than Woodcast, X‐lite and 3D‐printed polypropylene. When considering wrist stabilizing properties, PoP may still prove to be the preferred choice for wrist immobilization.Level of Evidence: Not applicable.
- 26 October 2024
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 11 (4) , e70065
Open AccessShort arm splints for wrist stabilization: A mechanical material test and cadaveric radiography study
Purpose: Documentation of the wrist stabilizing effect and mechanical properties of common splinting materials is warranted to support evidence‐based condition‐specific recommendations for wrist immobilization. The objectives of this study were to assess the wrist stabilizing properties of volar and dorsal short‐arm splints made of four different materials and evaluate the mechanical properties of the splinting materials.Methods: Dorsal and volar short arm splints made of plaster of Paris (PoP) (eight layers), Woodcast (2 mm, rigid vented), X‐lite (classic, two layers) or a 3D‐printed material (polypropylene) were sequentially mounted on 10 cadaveric arm specimens and fixed in a radiolucent fixture. This enabled the evaluation of maximum wrist flexion and extension relative under an orthogonal load of 42 N via radiographic images. In addition, a three‐point bending test was performed on ten sheet duplicates of each of the four splinting materials.Results: When applied as a volar splint, PoP had the highest capability to resist wrist flexion and extension. However, when applied as a dorsal splint, Woodcast exhibited a lower wrist flexion and a similar wrist extension. The 3D‐printed splints—both volar and dorsal—showed the highest mean wrist flexion and extension. The mechanical properties of the Woodcast, X‐lite and 3D‐printed splinting materials were very similar. PoP exhibited distinct properties with a stiffness of 146 (95% confidence interval [CI]: 120–173) N/mm and a deflection at Fmax of 0.6 (95% CI: 0.5–0.7) mm compared to ≤7.7 (95% CI: 7.4–7.9) N/mm and ≥20 (95% CI: 18–22) mm for the other materials.Conclusion: PoP displayed better wrist stabilizing properties and material stiffness than Woodcast, X‐lite and 3D‐printed polypropylene. When considering wrist stabilizing properties, PoP may still prove to be the preferred choice for wrist immobilization.Level of Evidence: Not applicable.
- 1 October 2024
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 106-B (10) , 1165-1175
Elbow kinematics with increased lengthening of a radial head arthroplasty evaluated with dynamic radiostereometric analysis
Aims: The aim of this study was to evaluate the kinematics of the elbow following increasing length of the radius with implantation of radial head arthroplasties (RHAs) using dynamic radiostereometry (dRSA).Methods: Eight human donor arms were examined by dRSA during motor-controlled flexion and extension of the elbow with the forearm in an unloaded neutral position, and in pronation and supination with and without a 10 N valgus or varus load, respectively. The elbows were examined before and after RHA with stem lengths of anatomical size, + 2 mm, and + 4 mm. The ligaments were maintained intact by using a step-cut lateral humeral epicondylar osteotomy, allowing the RHAs to be repeatedly exchanged. Bone models were obtained from CT scans, and specialized software was used to match these models with the dRSA recordings. The flexion kinematics of the elbow were described using anatomical coordinate systems to define translations and rotations with six degrees of freedom.Results: The greatest kinematic changes in the elbows were seen with the longest, + 4 mm, implant, which imposed a mean joint distraction of 2.8 mm in the radiohumeral joint and of 1.1 mm in the ulnohumeral joint, an increased mean varus angle of up to 2.4° for both the radius and the ulna, a mean shift of the radius of 2.0 mm in the ulnar direction, and a mean shift of the ulna of 1.0 mm posteriorly.Conclusion: The kinematics of the elbow deviated increasingly from those of the native joint with a 2 mm to a 4 mm lengthening of the radius. This confirms the importance of restoring the natural length of the radius when undertaking RHA.Cite this article: Bone Joint J 2024;106-B(10):1165–1175.
- 1 October 2024
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 106-B (10) , 1165-1175
Elbow kinematics with increased lengthening of a radial head arthroplasty evaluated with dynamic radiostereometric analysis
Aims: The aim of this study was to evaluate the kinematics of the elbow following increasing length of the radius with implantation of radial head arthroplasties (RHAs) using dynamic radiostereometry (dRSA).Methods: Eight human donor arms were examined by dRSA during motor-controlled flexion and extension of the elbow with the forearm in an unloaded neutral position, and in pronation and supination with and without a 10 N valgus or varus load, respectively. The elbows were examined before and after RHA with stem lengths of anatomical size, + 2 mm, and + 4 mm. The ligaments were maintained intact by using a step-cut lateral humeral epicondylar osteotomy, allowing the RHAs to be repeatedly exchanged. Bone models were obtained from CT scans, and specialized software was used to match these models with the dRSA recordings. The flexion kinematics of the elbow were described using anatomical coordinate systems to define translations and rotations with six degrees of freedom.Results: The greatest kinematic changes in the elbows were seen with the longest, + 4 mm, implant, which imposed a mean joint distraction of 2.8 mm in the radiohumeral joint and of 1.1 mm in the ulnohumeral joint, an increased mean varus angle of up to 2.4° for both the radius and the ulna, a mean shift of the radius of 2.0 mm in the ulnar direction, and a mean shift of the ulna of 1.0 mm posteriorly.Conclusion: The kinematics of the elbow deviated increasingly from those of the native joint with a 2 mm to a 4 mm lengthening of the radius. This confirms the importance of restoring the natural length of the radius when undertaking RHA.Cite this article: Bone Joint J 2024;106-B(10):1165–1175.
- 1 October 2024
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 106-B (10) , 1133-1140
Glenohumeral joint kinematics during apprehension-relocation test in patients with anterior shoulder instability and glenoid bone loss
Aims: This study aimed to quantify the shoulder kinematics during an apprehension-relocation test in patients with anterior shoulder instability (ASI) and glenoid bone loss using the radiostereometric analysis (RSA) method. Kinematics were compared with the patient’s contralateral healthy shoulder.Methods: A total of 20 patients with ASI and > 10% glenoid bone loss and a healthy contralateral shoulder were included. RSA imaging of the patient’s shoulders was performed during a repeated apprehension-relocation test. Bone volume models were generated from CT scans, marked with anatomical coordinate systems, and aligned with the digitally reconstructed bone projections on the RSA images. The glenohumeral joint (GHJ) kinematics were evaluated in the anteroposterior and superoinferior direction of: the humeral head centre location relative to the glenoid centre; and the humeral head contact point location on the glenoid.Results: During the apprehension test, the centre of the humeral head was 1.0 mm (95% CI 0.0 to 2.0) more inferior on the glenoid for the ASI shoulder compared with the healthy shoulder. Furthermore, the contact point of the ASI shoulder was 1.4 mm (95% CI 0.3 to 2.5) more anterior and 2.0 mm (95% CI 0.8 to 3.1) more inferior on the glenoid compared with the healthy shoulder. The contact point of the ASI shoulder was 1.2 mm (95% CI 0.2 to 2.6) more anterior during the apprehension test compared to the relocation test.Conclusion: The humeral head centre was located more inferior, and the GHJ contact point was located both more anterior and inferior during the apprehension test for the ASI shoulders than the healthy shoulders. Furthermore, the contact point displacement between the apprehension and relocation test revealed increased joint laxity for the ASI shoulder than the healthy shoulders. These results contribute to existing knowledge that ASI shoulders with glenoid bone loss may also suffer from inferior shoulder instability.Cite this article: Bone Joint J 2024;106-B(10):1133–1140.
- 1 October 2024
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 106-B (10) , 1133-1140
Glenohumeral joint kinematics during apprehension-relocation test in patients with anterior shoulder instability and glenoid bone loss
Aims: This study aimed to quantify the shoulder kinematics during an apprehension-relocation test in patients with anterior shoulder instability (ASI) and glenoid bone loss using the radiostereometric analysis (RSA) method. Kinematics were compared with the patient’s contralateral healthy shoulder.Methods: A total of 20 patients with ASI and > 10% glenoid bone loss and a healthy contralateral shoulder were included. RSA imaging of the patient’s shoulders was performed during a repeated apprehension-relocation test. Bone volume models were generated from CT scans, marked with anatomical coordinate systems, and aligned with the digitally reconstructed bone projections on the RSA images. The glenohumeral joint (GHJ) kinematics were evaluated in the anteroposterior and superoinferior direction of: the humeral head centre location relative to the glenoid centre; and the humeral head contact point location on the glenoid.Results: During the apprehension test, the centre of the humeral head was 1.0 mm (95% CI 0.0 to 2.0) more inferior on the glenoid for the ASI shoulder compared with the healthy shoulder. Furthermore, the contact point of the ASI shoulder was 1.4 mm (95% CI 0.3 to 2.5) more anterior and 2.0 mm (95% CI 0.8 to 3.1) more inferior on the glenoid compared with the healthy shoulder. The contact point of the ASI shoulder was 1.2 mm (95% CI 0.2 to 2.6) more anterior during the apprehension test compared to the relocation test.Conclusion: The humeral head centre was located more inferior, and the GHJ contact point was located both more anterior and inferior during the apprehension test for the ASI shoulders than the healthy shoulders. Furthermore, the contact point displacement between the apprehension and relocation test revealed increased joint laxity for the ASI shoulder than the healthy shoulders. These results contribute to existing knowledge that ASI shoulders with glenoid bone loss may also suffer from inferior shoulder instability.Cite this article: Bone Joint J 2024;106-B(10):1133–1140.
- Open Access
- 14 May 2023
- Published by MDPI AG in Antibiotics
- Vol. 12 (5) , 907
Concentrations of Co-Administered Meropenem and Vancomycin in Spinal Tissues Relevant for the Treatment of Pyogenic Spondylodiscitis—An Experimental Microdialysis Study
Co-administration of meropenem and vancomycin has been suggested as a systemic empirical antibiotic treatment of pyogenic spondylodiscitis. The aim of this study was, in an experimental porcine model, to evaluate the percentage of an 8-h dosing interval of co-administered meropenem and vancomycin concentrations above the relevant minimal inhibitory concentrations (MICs) (%T>MIC) in spinal tissues using microdialysis. Eight female pigs (Danish Landrace breed, weight 78–82 kg) received a single-dose bolus infusion of 1000 mg of meropenem and 1000 mg vancomycin simultaneously before microdialysis sampling. Microdialysis catheters were applied in the third cervical (C3) vertebral cancellous bone, the C3–C4 intervertebral disc, paravertebral muscle, and adjacent subcutaneous tissue. Plasma samples were obtained for reference. The main finding was that for both drugs, the %T>MICs were highly reliant on the applied MIC target, but were heterogeneous across all targeted tissues, ranging from 25–90% for meropenem, and 10–100% for vancomycin. For both MIC targets, the highest %T>MIC was demonstrated in plasma, and the lowest %T>MIC was demonstrated in the vertebral cancellous bone for meropenem, and in the intervertebral disc for vancomycin. When indicated, our findings may suggest a more aggressive dosing approach of both meropenem and vancomycin to increase the spinal tissue concentrations to treat the full spectrum of potentially encountered bacteria in a spondylodiscitis treatment setting.
- 14 May 2023
- Published by MDPI AG in Antibiotics
- Vol. 12 (5) , 907
Open AccessConcentrations of Co-Administered Meropenem and Vancomycin in Spinal Tissues Relevant for the Treatment of Pyogenic Spondylodiscitis—An Experimental Microdialysis Study
Co-administration of meropenem and vancomycin has been suggested as a systemic empirical antibiotic treatment of pyogenic spondylodiscitis. The aim of this study was, in an experimental porcine model, to evaluate the percentage of an 8-h dosing interval of co-administered meropenem and vancomycin concentrations above the relevant minimal inhibitory concentrations (MICs) (%T>MIC) in spinal tissues using microdialysis. Eight female pigs (Danish Landrace breed, weight 78–82 kg) received a single-dose bolus infusion of 1000 mg of meropenem and 1000 mg vancomycin simultaneously before microdialysis sampling. Microdialysis catheters were applied in the third cervical (C3) vertebral cancellous bone, the C3–C4 intervertebral disc, paravertebral muscle, and adjacent subcutaneous tissue. Plasma samples were obtained for reference. The main finding was that for both drugs, the %T>MICs were highly reliant on the applied MIC target, but were heterogeneous across all targeted tissues, ranging from 25–90% for meropenem, and 10–100% for vancomycin. For both MIC targets, the highest %T>MIC was demonstrated in plasma, and the lowest %T>MIC was demonstrated in the vertebral cancellous bone for meropenem, and in the intervertebral disc for vancomycin. When indicated, our findings may suggest a more aggressive dosing approach of both meropenem and vancomycin to increase the spinal tissue concentrations to treat the full spectrum of potentially encountered bacteria in a spondylodiscitis treatment setting.