Jing Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jing Zhang has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Jiahong Zhang
Kunming University of Science and Technology
8 shared publications - Yingna Li
Kunming University of Science and Technology
4 shared publications - Weichang Li
Faculty of Information Engineering and Automation, Kunming University of Science and Technology, Kunming, China
3 shared publications - Na Li
Faculty of Information Engineering and Automation and Key Laboratory of Artifcial Intelligence in Yunnan Province, Kunming University of Science and Technology, Kunming, China
2 shared publications - Shaoqi He
Kunming University of Science and Technology
2 shared publications - Yang Yang
School of Information Engineering and Automation Kunming University of Science and Technology Kunming China
2 shared publications
Latest Publications
- 1 December 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 13 (23) , 57726-57736
An Optical Intensive Electric Field Sensor Based on LiNbO 3 Crystal for Measuring Both the AC and DC Electric Fields
- 1 December 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 13 (23) , 57726-57736
An Optical Intensive Electric Field Sensor Based on LiNbO 3 Crystal for Measuring Both the AC and DC Electric Fields
- Open Access
- 14 March 2026
- Published by Elsevier in Results in Engineering
- Vol. 30
A robust hybrid framework for load forecasting in smart grid
- 14 March 2026
- Published by Elsevier in Results in Engineering
- Vol. 30
Open AccessA robust hybrid framework for load forecasting in smart grid
- 22 November 2025
- Published by Elsevier in Electric Power Systems Research
- Vol. 253
Hybrid model for short-term wind power prediction by the SAO and a parallel architecture of LSTM and GRU
- 22 November 2025
- Published by Elsevier in Electric Power Systems Research
- Vol. 253
Hybrid model for short-term wind power prediction by the SAO and a parallel architecture of LSTM and GRU
- 8 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 43 (24) , 11119-11126
A Compact Transient Electric Field Sensor Using a Pair of Conjugate Lithium Niobate Crystal
In this paper a compact, high-sensitivity Pockels optical electric field sensor using a pair of Lithium Niobate (LiNbO3) conjugate crystal. By using the side-by-side conjugate crystal both the sensitivity and temperature stability of the sensor are enhanced, while the sensor size remains almost the same. The dimension of the fabricated sensor is 70 × 15 × 10 mm³. Experiment results demonstrate, for the measured nanosecond electromagnetic impulse (EMP) in the time domain, the relative error in the waveform rise time tr is 20.00%, and the maximum error in the pulse width tw is 0.20%, while for the measured lightning electromagnetic impulse (LEMP), the relative errors of in the tr and tw are 16.67% and 0.20% respectively. The measured nanosecond EMP and the LEMP showing good consistency with the input voltage waveform. The sensitivities reach 1.37 mV/(kV·m−1) for measuring the nanosecond EMP and reach 3.04 mV/(kV·m−1) for measuring the LEMP. Besides, in the frequency domain, the sensor output fluctuates within ± 7 dB in the range of 100 kHz to 1 GHz. All these results real that the sensor can be used to accurately measure the time-domain waveforms of the transient EMP.
- 8 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 43 (24) , 11119-11126
A Compact Transient Electric Field Sensor Using a Pair of Conjugate Lithium Niobate Crystal
In this paper a compact, high-sensitivity Pockels optical electric field sensor using a pair of Lithium Niobate (LiNbO3) conjugate crystal. By using the side-by-side conjugate crystal both the sensitivity and temperature stability of the sensor are enhanced, while the sensor size remains almost the same. The dimension of the fabricated sensor is 70 × 15 × 10 mm³. Experiment results demonstrate, for the measured nanosecond electromagnetic impulse (EMP) in the time domain, the relative error in the waveform rise time tr is 20.00%, and the maximum error in the pulse width tw is 0.20%, while for the measured lightning electromagnetic impulse (LEMP), the relative errors of in the tr and tw are 16.67% and 0.20% respectively. The measured nanosecond EMP and the LEMP showing good consistency with the input voltage waveform. The sensitivities reach 1.37 mV/(kV·m−1) for measuring the nanosecond EMP and reach 3.04 mV/(kV·m−1) for measuring the LEMP. Besides, in the frequency domain, the sensor output fluctuates within ± 7 dB in the range of 100 kHz to 1 GHz. All these results real that the sensor can be used to accurately measure the time-domain waveforms of the transient EMP.
- 14 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 21 (6) , 4543-4553
Enhancing Detection of False Data Injection Attacks in Smart Grid Using Spectral Graph Neural Network
The smart grid (SG) exemplifies the utilization of industrial cyber physical systems within the electric power industry. Ensuring information security is an paramount concern in SG. However, false data injection attack (FDIA) poses considerable risk in manipulating data and compromising SG functions. The existing methods that utilize spectral relationships to detect FDIA primarily target sudden changes and cannot be applied to comb-shaped signal variations. So, addressing this issue, this article introduces a spectral graph neural network-based approach utilizing Bernstein polynomials to approximate spectral graph filters for detecting FDIA. The filter coefficients, obtained through neural network training, enabling to create comb-shaped and high-pass spectral filters applied to the different signal variations. To assess the efficacy of our model, we contrast it with other latest methods and conduct experiments on IEEE 14, 30, and 118 bus systems. The results show an average performance improvement 9.22% of our model relative to the latest models.
- 14 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 21 (6) , 4543-4553
Enhancing Detection of False Data Injection Attacks in Smart Grid Using Spectral Graph Neural Network
The smart grid (SG) exemplifies the utilization of industrial cyber physical systems within the electric power industry. Ensuring information security is an paramount concern in SG. However, false data injection attack (FDIA) poses considerable risk in manipulating data and compromising SG functions. The existing methods that utilize spectral relationships to detect FDIA primarily target sudden changes and cannot be applied to comb-shaped signal variations. So, addressing this issue, this article introduces a spectral graph neural network-based approach utilizing Bernstein polynomials to approximate spectral graph filters for detecting FDIA. The filter coefficients, obtained through neural network training, enabling to create comb-shaped and high-pass spectral filters applied to the different signal variations. To assess the efficacy of our model, we contrast it with other latest methods and conduct experiments on IEEE 14, 30, and 118 bus systems. The results show an average performance improvement 9.22% of our model relative to the latest models.
- 4 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
A Magnetic Field Sensor With No Electric Field Perturbation Based on Dual LiNbO3 Crystals
A magnetic field sensor with no electric perturbation based on LiNbO3 twin crystals has been proposed and experimentally demonstrated. The interference of external electric fields accompanying the magnetic field can be eliminated by utilizing a loop antenna equipped with two LiNbO3 crystals positioned along the +x and -x axes. Additionally, the increased electro-optic (EO) modulation length enhances the sensitivity of the sensor. Experimental results indicate that when an external magnetic field along the z-axis is accompanied by an external electric field along the x-axis is applied on the sensor, the output of the sensor is -102.5 dBm (which is almost equal to the noise floor), which demonstrates that the interference from the accompanied electric field can be eliminated. When an external magnetic field along the y-axis, accompanied by an external electric field along the x-axis, is applied, the sensor output is -83.4 dBm at 850 MHz. With an input magnetic field frequency of 850 MHz, the lowest magnetic field the sensor can detect is 67. 93 dBμA/m, and the highest is 213.81 dBμA/m, which results in a dynamic range of 146 dB and a sensitivity of 1.083 dBm/(dBμA/m).
- 4 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
A Magnetic Field Sensor With No Electric Field Perturbation Based on Dual LiNbO3 Crystals
A magnetic field sensor with no electric perturbation based on LiNbO3 twin crystals has been proposed and experimentally demonstrated. The interference of external electric fields accompanying the magnetic field can be eliminated by utilizing a loop antenna equipped with two LiNbO3 crystals positioned along the +x and -x axes. Additionally, the increased electro-optic (EO) modulation length enhances the sensitivity of the sensor. Experimental results indicate that when an external magnetic field along the z-axis is accompanied by an external electric field along the x-axis is applied on the sensor, the output of the sensor is -102.5 dBm (which is almost equal to the noise floor), which demonstrates that the interference from the accompanied electric field can be eliminated. When an external magnetic field along the y-axis, accompanied by an external electric field along the x-axis, is applied, the sensor output is -83.4 dBm at 850 MHz. With an input magnetic field frequency of 850 MHz, the lowest magnetic field the sensor can detect is 67. 93 dBμA/m, and the highest is 213.81 dBμA/m, which results in a dynamic range of 146 dB and a sensitivity of 1.083 dBm/(dBμA/m).
- 1 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (2) , 1218-1227
Surface Electric Field Measurement of Composite Insulator Using an Optical Waveguide Sensor
In this paper, an integrated optical waveguide sensor is designed and developed to comprehensively analyze the surface electric field distribution characteristics of composite insulators. Based on the optical waveguide electric field sensor, a measuring system for the surface axial and radial electric fields of composite insulators is built, and the axial and radial electric fields along the surface of composite insulator is measured under normal, damaged and internally defects. Based on the optical waveguide electric field sensor, an experimental system is setup for measuring the axial and radial electric fields along surface of composite insulators under normal, damaged and internally defective conditions. The experimental results showed that when a 10 kV power frequency voltage is connected, the radial and axial electric fields at the low and high voltage ends of the normal insulator are 21.53 kV/m, 53.07 kV/m and 47.55 kV/m, 105.12 kV/m respectively. When the insulator surface is damaged, the radial and axial electric field intensities at the damaged locations increased by 37.59%-204.85% and 12.89%-32.69%, respectively. When an internal defect occurred, the radial and axial electric field along the defect area increased by 18% and decreased by 127.72%, respectively. The radial electric field is more affected by the defect. The comparison with the calculated results shows that the integrated optical waveguide electric field sensor has great potential capability to be used for measuring the surface electric field of insulators.
- 1 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 32 (2) , 1218-1227
Surface Electric Field Measurement of Composite Insulator Using an Optical Waveguide Sensor
In this paper, an integrated optical waveguide sensor is designed and developed to comprehensively analyze the surface electric field distribution characteristics of composite insulators. Based on the optical waveguide electric field sensor, a measuring system for the surface axial and radial electric fields of composite insulators is built, and the axial and radial electric fields along the surface of composite insulator is measured under normal, damaged and internally defects. Based on the optical waveguide electric field sensor, an experimental system is setup for measuring the axial and radial electric fields along surface of composite insulators under normal, damaged and internally defective conditions. The experimental results showed that when a 10 kV power frequency voltage is connected, the radial and axial electric fields at the low and high voltage ends of the normal insulator are 21.53 kV/m, 53.07 kV/m and 47.55 kV/m, 105.12 kV/m respectively. When the insulator surface is damaged, the radial and axial electric field intensities at the damaged locations increased by 37.59%-204.85% and 12.89%-32.69%, respectively. When an internal defect occurred, the radial and axial electric field along the defect area increased by 18% and decreased by 127.72%, respectively. The radial electric field is more affected by the defect. The comparison with the calculated results shows that the integrated optical waveguide electric field sensor has great potential capability to be used for measuring the surface electric field of insulators.
- 30 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-13
Transient Surface Electric Field Measurement of the Composite Insulators Using an Integrated Optics Sensor
An integrated optics E-field sensor has been developed and used to measure the axial and radial transient surface E-field distribution of a 10 kV composite insulator under the 1.2/50 μs lightning electromagnetic impulse (LEMP). The experimental and simulation results showed that with a 40 mm length internal defect inside the composite insulator, the axial E-field increased tenfold at the positions far from the defect, with little change in the time-domain waveform. However, near the defect, the radial E-field increased threefold, causing significant waveform distortion. When a 60 mm length internal defect, the positions far from the defect, with slight changes in the time-domain waveform. Conversely, near the defect, the radial E-field increased by more than a hundredfold, resulting in severe waveform distortion. When bird pecking damage area of the sheds does not exceed 12% of the total shed area, the surface axial and radial E-field changed by approximately 20%, with slight variation in the time-domain waveform. When the damaged area reaches 25% of the total shed area, the maximum radial E-field increased by over one time, with minimal change in the time-domain waveforms, and the change in radial E-field intensity is greater than that in the axial E-field. These results can serve as a basis for fault identification and optimization design for composite insulators under transient voltages.
- 30 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-13
Transient Surface Electric Field Measurement of the Composite Insulators Using an Integrated Optics Sensor
An integrated optics E-field sensor has been developed and used to measure the axial and radial transient surface E-field distribution of a 10 kV composite insulator under the 1.2/50 μs lightning electromagnetic impulse (LEMP). The experimental and simulation results showed that with a 40 mm length internal defect inside the composite insulator, the axial E-field increased tenfold at the positions far from the defect, with little change in the time-domain waveform. However, near the defect, the radial E-field increased threefold, causing significant waveform distortion. When a 60 mm length internal defect, the positions far from the defect, with slight changes in the time-domain waveform. Conversely, near the defect, the radial E-field increased by more than a hundredfold, resulting in severe waveform distortion. When bird pecking damage area of the sheds does not exceed 12% of the total shed area, the surface axial and radial E-field changed by approximately 20%, with slight variation in the time-domain waveform. When the damaged area reaches 25% of the total shed area, the maximum radial E-field increased by over one time, with minimal change in the time-domain waveforms, and the change in radial E-field intensity is greater than that in the axial E-field. These results can serve as a basis for fault identification and optimization design for composite insulators under transient voltages.