NKNakaret Kano

Nakaret Kano

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Nakaret Kano has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effects of Induced Current From High-Voltage Transmission Lines on Voltage-Limiting Device Operation in Electrified Monorail Systems

    by Warayut Kampeerawat, Nakaret Kano, Kittiphan Nawakiattikorn, Chaiyut Sumpavakup

    Voltage-limiting devices (VLDs) are installed in DC railways to limit rail potential and touch voltage by momentarily bonding the negative return conductor to the station grounding grid. Although VLDs act on the return circuit, their switching changes the DC network topology and can also affect the positive-conductor voltage that supplies traction loads. In elevated urban corridors, DC feeders may run alongside high-voltage AC (HVAC) transmission lines, where electromagnetic coupling can inject an AC-induced current into the traction network. This paper studies the combined influence of VLD operation and HVAC-induced current on an operational monorail. A coupled train-movement and nodal DC-network model is developed in MATLAB and applied to the Bangkok Yellow Line. Five case studies are considered: baseline multi-train operation, forced VLD operation, magnetic-field estimation versus HVAC separation distance, induced-current levels of 50–200 A, and headway sensitivity. Results show that VLD closure clamps the negative-conductor potential near ground but can lower the local minimum positive-conductor voltage by about 30–40 V near the operating station. When induced current is present, both conductor potentials rise, with the negative conductor being more sensitive (approximately 45–178% increase over the examined range). Increasing headway reduces traction-driven rail-potential excursions and lessens the impact of VLD switching; however, induced-current effects remain noticeable under light traffic. The findings support practical VLD siting and threshold selection for monorail corridors co-located with HVAC infrastructure.

  • Analysis of Energy Efficiency and Resilience for AC Railways With Solar PV and Energy Storage Systems

    by Nutthaka Chinomi, Zhongbei Tian, Ning Yang, Nakaret Kano, Lin Jiang

    Railway energy consumption and its environmental repercussions, alongside operational costs, are pivotal concerns necessitating attention. With escalating energy prices, renewable energy sources emerge as compelling alternatives to traditional systems, offering clean and cost-effective solutions while advancing decarbonization efforts. This study delves into the integration of photovoltaic (PV) and energy storage systems (ESS) into AC railway traction power supply systems (TPSS) with Direct Feed (DF) and Autotransformer (AT) configurations. The aim is to evaluate energy performance, overhead line current distribution, and conductor temperature. A case study is conducted on a 100 km AC rail route with six passenger stations and suburban trains operational throughout a full day, illustrating the impact of PV and ESS integration in both DF and AT setups. Findings reveal improved voltage drops and significant reductions in substation supply power, energy consumption, contact wire current, and temperature. Notably, a 6.5% and 9.6% reduction in supply energy is observed with PV and ESS integration for DF and AT configurations, respectively. These results underscore the imperative of the integration to optimize energy management in railway systems, fostering efficient energy utilization, potential cost savings, and environmental sustainability.


  • Renewable Sources and Energy Storage Optimization to Minimize the Global Costs of Railways

    by Nakaret Kano, Zhongbei Tian, Nutthaka Chinomi, Xiaoguang Wei, Stuart Hillmansen

    Climate change is one of the biggest global issues for humanity these days, and its effect has become more severe. The transport sector accounts for around 30% of greenhouse gas emissions, which need to be decarbonized urgently. Railway electrification is one of the low-carbon solutions, but it still relies on power grids causing carbon emissions. To further decarbonize electric railways, the renewable energy sources (RESs) and energy storage system (ESS) integration scheme for railway traction power network has been proposed. This paper developed the energy management system to calculate the energy flow and global cost. Moreover, contact wire loss and conversion loss were considered. The optimization problem to find the optimal capacity and location of the PV farm, wind farm and energy storage system to achieve the lowest global daily costs was solved by the Brute Force Algorithm. The traction network of the High Speed 2 Railway in the UK has been taken as a case study. Results revealed that the global cost and carbon emissions are reduced considerably with both ESS and RESs installed. In the scenario of the ESS alone, 1.3% of the global cost is saved by capturing the regenerative energy and reusing it. Furthermore, this figure goes up to 10% and 62% when the PV and wind farms are integrated, respectively. When considering all variables, it is found that installing the wind farm is a more economical option than the PV farm. The study also shows that the optimal locations to install the plants and ESS vary by scenario.