Karl-Philippe Beaudet
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Karl-Philippe Beaudet has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
Juan Verde
Inria, Strasbourg, France
4 shared publicationsSidaty El Hadramy
Inria, Strasbourg, France
4 shared publicationsStéphane Cotin
Inria, Strasbourg, France
4 shared publicationsPhilippe Cattin
University of Basel, Basel, Switzerland
2 shared publications- Stéphane Cotin
Inria, Strasbourg, France
2 shared publications - Alain García Vázquez
IHU, Institute of Image-Guided Surgery, 1 Pl. de l’Hôpital, 67000 Strasbourg, France
1 shared publication
Latest Publications
- Open Access
Reimagining Nodal Staging in Colorectal Cancer: Toward a Novel Non-Invasive Imaging Approach
Colorectal cancer (CRC) remains the third most common malignancy worldwide and a leading cause of cancer mortality, largely driven by metastatic dissemination. Among metastatic routes, lymphatic spread is crucial to determine the prognosis and establish an adequate therapeutic strategy. Lymph node metastasis (LNM) defines stage III disease in the TNM classification, guiding adjuvant chemotherapy and surgical planning. However, nodal staging based on lymphadenectomy and histopathology is invasive, time-consuming, and may lead to overtreatment. Conventional imaging modalities, including computed tomography, magnetic resonance imaging, and endorectal ultrasound, show limited sensitivity and specificity for small or micro-metastatic nodes. Despite multimodal progress, no non-invasive technique reliably identifies malignant nodes in real time. PET–MRI, contrast-enhanced ultrasound, photoacoustic and fluorescence approaches, ICG mapping, and sentinel node biopsy improve detection but remain limited by specificity, cost, or availability. Extranodal extension (ENE) and tumor deposits (TDs) carry major prognostic value, reflecting aggressive biology and association with distant spread. Meanwhile, phylogenetic studies challenge linear dissemination models, indicating that some metastases arise directly from the primary tumor or TDs rather than LNMs. These data support refinement of staging and surgical strategies according to tumor biology rather than purely anatomical criteria. High-frequency quantitative ultrasound (HF-QUS) enables real-time, operator-independent, three-dimensional nodal assessment with reported sensitivity and specificity exceeding 85%. Combined with artificial intelligence and molecular profiling, it may support biologically informed staging, reduce unnecessary surgery, and foster precision oncology. Lymphatic dissemination in CRC offers a platform to merge tumor biology with technological innovation, where advanced imaging, molecular insight, and artificial intelligence may redefine nodal staging toward precision, non-invasive care.
Open AccessReimagining Nodal Staging in Colorectal Cancer: Toward a Novel Non-Invasive Imaging Approach
Colorectal cancer (CRC) remains the third most common malignancy worldwide and a leading cause of cancer mortality, largely driven by metastatic dissemination. Among metastatic routes, lymphatic spread is crucial to determine the prognosis and establish an adequate therapeutic strategy. Lymph node metastasis (LNM) defines stage III disease in the TNM classification, guiding adjuvant chemotherapy and surgical planning. However, nodal staging based on lymphadenectomy and histopathology is invasive, time-consuming, and may lead to overtreatment. Conventional imaging modalities, including computed tomography, magnetic resonance imaging, and endorectal ultrasound, show limited sensitivity and specificity for small or micro-metastatic nodes. Despite multimodal progress, no non-invasive technique reliably identifies malignant nodes in real time. PET–MRI, contrast-enhanced ultrasound, photoacoustic and fluorescence approaches, ICG mapping, and sentinel node biopsy improve detection but remain limited by specificity, cost, or availability. Extranodal extension (ENE) and tumor deposits (TDs) carry major prognostic value, reflecting aggressive biology and association with distant spread. Meanwhile, phylogenetic studies challenge linear dissemination models, indicating that some metastases arise directly from the primary tumor or TDs rather than LNMs. These data support refinement of staging and surgical strategies according to tumor biology rather than purely anatomical criteria. High-frequency quantitative ultrasound (HF-QUS) enables real-time, operator-independent, three-dimensional nodal assessment with reported sensitivity and specificity exceeding 85%. Combined with artificial intelligence and molecular profiling, it may support biologically informed staging, reduce unnecessary surgery, and foster precision oncology. Lymphatic dissemination in CRC offers a platform to merge tumor biology with technological innovation, where advanced imaging, molecular insight, and artificial intelligence may redefine nodal staging toward precision, non-invasive care.
- 21 May 2026
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 21 (6) , 1351-1358
DefSynUS: Real-time patient-specific intrahepatic vessel identification via deformation-aware CT-US domain adaptation
Laparoscopic ultrasound (LUS) enhances the safety of liver surgery by visualizing intrahepatic vessels in real time. Still, vessel identification remains difficult due to probe constraints, complex vascular structure, and tissue deformation. This work aims to enable real-time, patient-specific vessel identification that remains robust under deformation through deformable ultrasound augmentation. Preoperative CT vessel annotations are used to generate synthetic ultrasound data via optimized physics-based rendering, coupled with domain adaptation to intraoperative ultrasound. The rendering is trained end to end for vessel identification and patient specificity, eliminating the need for preoperative ultrasound. A deformation-aware augmentation simulates realistic intraoperative motion and tissue deformation within the rendering pipeline. In abdominal phantom and limited clinical feasibility experiments (single-case clinical evaluation), the framework achieved real-time intrahepatic vessel-branch identification, maintaining performance under new patient poses. The framework enables real-time vessel identification without preoperative ultrasound and supports technical feasibility, but multi-patient validation is still needed for generalizability and clinical feasibility.
- 21 May 2026
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 21 (6) , 1351-1358
DefSynUS: Real-time patient-specific intrahepatic vessel identification via deformation-aware CT-US domain adaptation
Laparoscopic ultrasound (LUS) enhances the safety of liver surgery by visualizing intrahepatic vessels in real time. Still, vessel identification remains difficult due to probe constraints, complex vascular structure, and tissue deformation. This work aims to enable real-time, patient-specific vessel identification that remains robust under deformation through deformable ultrasound augmentation. Preoperative CT vessel annotations are used to generate synthetic ultrasound data via optimized physics-based rendering, coupled with domain adaptation to intraoperative ultrasound. The rendering is trained end to end for vessel identification and patient specificity, eliminating the need for preoperative ultrasound. A deformation-aware augmentation simulates realistic intraoperative motion and tissue deformation within the rendering pipeline. In abdominal phantom and limited clinical feasibility experiments (single-case clinical evaluation), the framework achieved real-time intrahepatic vessel-branch identification, maintaining performance under new patient poses. The framework enables real-time vessel identification without preoperative ultrasound and supports technical feasibility, but multi-patient validation is still needed for generalizability and clinical feasibility.
- 27 September 2025
- Published by Springer Nature
- p. 53-62
Optimization-Based Calibration for Intravascular Ultrasound Volume Reconstruction
- 27 September 2025
- Published by Springer Nature
- p. 53-62
Optimization-Based Calibration for Intravascular Ultrasound Volume Reconstruction
- Open Access
Optimization-Based Calibration for Intravascular Ultrasound Volume Reconstruction
Intraoperative ultrasound images are inherently challenging to interpret in liver surgery due to the limited field of view and complex anatomical structures. Bridging the gap between preoperative and intraoperative data is crucial for effective surgical guidance. 3D IntraVascular UltraSound (IVUS) offers a potential solution by enabling the reconstruction of the entire organ, which facilitates registration between preoperative computed tomography (CT) scans and intraoperative IVUS images. In this work, we propose an optimization-based calibration method using a 3D-printed phantom for accurate 3D Intravascular Ultrasound volume reconstruction. Our approach ensures precise alignment of tracked IVUS data with preoperative CT images, improving intraoperative navigation. We validated our method using in vivo swine liver images, achieving a calibration error from 0.88 to 1.80 mm and a registration error from 3.40 to 5.71 mm between the 3D IVUS data and the corresponding CT scan. Our method provides a reliable and accurate means of calibration and volume reconstruction. It can be used to register intraoperative ultrasound images with preoperative CT images in the context of liver surgery, and enhance intraoperative guidance.
Open AccessOptimization-Based Calibration for Intravascular Ultrasound Volume Reconstruction
Intraoperative ultrasound images are inherently challenging to interpret in liver surgery due to the limited field of view and complex anatomical structures. Bridging the gap between preoperative and intraoperative data is crucial for effective surgical guidance. 3D IntraVascular UltraSound (IVUS) offers a potential solution by enabling the reconstruction of the entire organ, which facilitates registration between preoperative computed tomography (CT) scans and intraoperative IVUS images. In this work, we propose an optimization-based calibration method using a 3D-printed phantom for accurate 3D Intravascular Ultrasound volume reconstruction. Our approach ensures precise alignment of tracked IVUS data with preoperative CT images, improving intraoperative navigation. We validated our method using in vivo swine liver images, achieving a calibration error from 0.88 to 1.80 mm and a registration error from 3.40 to 5.71 mm between the 3D IVUS data and the corresponding CT scan. Our method provides a reliable and accurate means of calibration and volume reconstruction. It can be used to register intraoperative ultrasound images with preoperative CT images in the context of liver surgery, and enhance intraoperative guidance.
- Open Access
Optimization-Based Calibration for Intravascular Ultrasound Volume Reconstruction
Intraoperative ultrasound images are inherently challenging to interpret in liver surgery due to the limited field of view and complex anatomical structures. Bridging the gap between preoperative and intraoperative data is crucial for effective surgical guidance. 3D IntraVascular UltraSound (IVUS) offers a potential solution by enabling the reconstruction of the entire organ, which facilitates registration between preoperative computed tomography (CT) scans and intraoperative IVUS images. In this work, we propose an optimization-based calibration method using a 3D-printed phantom for accurate 3D Intravascular Ultrasound volume reconstruction. Our approach ensures precise alignment of tracked IVUS data with preoperative CT images, improving intraoperative navigation. We validated our method using in vivo swine liver images, achieving a calibration error from 0.88 to 1.80 mm and a registration error from 3.40 to 5.71 mm between the 3D IVUS data and the corresponding CT scan. Our method provides a reliable and accurate means of calibration and volume reconstruction. It can be used to register intraoperative ultrasound images with preoperative CT images in the context of liver surgery, and enhance intraoperative guidance.
Open AccessOptimization-Based Calibration for Intravascular Ultrasound Volume Reconstruction
Intraoperative ultrasound images are inherently challenging to interpret in liver surgery due to the limited field of view and complex anatomical structures. Bridging the gap between preoperative and intraoperative data is crucial for effective surgical guidance. 3D IntraVascular UltraSound (IVUS) offers a potential solution by enabling the reconstruction of the entire organ, which facilitates registration between preoperative computed tomography (CT) scans and intraoperative IVUS images. In this work, we propose an optimization-based calibration method using a 3D-printed phantom for accurate 3D Intravascular Ultrasound volume reconstruction. Our approach ensures precise alignment of tracked IVUS data with preoperative CT images, improving intraoperative navigation. We validated our method using in vivo swine liver images, achieving a calibration error from 0.88 to 1.80 mm and a registration error from 3.40 to 5.71 mm between the 3D IVUS data and the corresponding CT scan. Our method provides a reliable and accurate means of calibration and volume reconstruction. It can be used to register intraoperative ultrasound images with preoperative CT images in the context of liver surgery, and enhance intraoperative guidance.
- 3 October 2024
- Published by Springer Nature
- p. 649-659
Towards Real-Time Intrahepatic Vessel Identification in Intraoperative Ultrasound-Guided Liver Surgery
- 3 October 2024
- Published by Springer Nature
- p. 649-659
Towards Real-Time Intrahepatic Vessel Identification in Intraoperative Ultrasound-Guided Liver Surgery