Tianle Zeng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tianle Zeng has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Dominic Jones
University of Leeds
2 shared publications - Gerardo Loza Galindo
School of Computer Science, University of Leeds, Leeds, U.K.
2 shared publications - Junlei Hu
University of Leeds
2 shared publications - Pietro Valdastri
University of Leeds
2 shared publications - Dengke He
China University of Mining and Technology (Beijing), Beijing 100083, People’s Republic of China
1 shared publication - Duygu Sarikaya
University of Leeds
1 shared publication
Latest Publications
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 11 (9) , 1-8
TARIC: Memory-Augmented Traversability-Aware Outdoor VLN Under Interrupted Semantic Cues
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 11 (9) , 1-8
TARIC: Memory-Augmented Traversability-Aware Outdoor VLN Under Interrupted Semantic Cues
- 30 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 45 (5) , 2100-2112
NeeCo: Image Synthesis of Novel Instrument States Based on Dynamic and Deformable 3-D Gaussian Reconstruction
Computer vision-based technologies significantly enhance surgical automation by advancing tool tracking, detection, and localization. However, Current data-driven approaches are data-voracious, requiring large, high-quality labeled image datasets. Our Work introduces a novel dynamic Gaussian Splatting technique to address the data scarcity in surgical image datasets. We propose a dynamic Gaussian model to represent dynamic surgical scenes, enabling the rendering of surgical instruments from unseen viewpoints and deformations with real tissue backgrounds. We utilize a dynamic training adjustment strategy to address challenges posed by poorly calibrated camera poses from real-world scenarios. Additionally, automatically generate annotations for our synthetic data. For evaluation, we constructed a new dataset featuring seven scenes with 14,000 frames of tool and camera motion and tool jaw articulation, with a background of an exvivo porcine model. Using this dataset, we synthetically replicate the scene deformation from the ground truth data, allowing direct comparisons of synthetic image quality. Experimental results illustrate that our method generates photo-realistic labeled image datasets with the highest PSNR (29.87). We further evaluate the performance of medical-specific neural networks trained on real and synthetic images using an unseen real-world image dataset. Our results show that the performance of models trained on synthetic images generated by the proposed method outperforms those trained with state-of-the-art standard data augmentation by 10%, leading to an overall improvement in model performances by nearly 15%.
- 30 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 45 (5) , 2100-2112
NeeCo: Image Synthesis of Novel Instrument States Based on Dynamic and Deformable 3-D Gaussian Reconstruction
Computer vision-based technologies significantly enhance surgical automation by advancing tool tracking, detection, and localization. However, Current data-driven approaches are data-voracious, requiring large, high-quality labeled image datasets. Our Work introduces a novel dynamic Gaussian Splatting technique to address the data scarcity in surgical image datasets. We propose a dynamic Gaussian model to represent dynamic surgical scenes, enabling the rendering of surgical instruments from unseen viewpoints and deformations with real tissue backgrounds. We utilize a dynamic training adjustment strategy to address challenges posed by poorly calibrated camera poses from real-world scenarios. Additionally, automatically generate annotations for our synthetic data. For evaluation, we constructed a new dataset featuring seven scenes with 14,000 frames of tool and camera motion and tool jaw articulation, with a background of an exvivo porcine model. Using this dataset, we synthetically replicate the scene deformation from the ground truth data, allowing direct comparisons of synthetic image quality. Experimental results illustrate that our method generates photo-realistic labeled image datasets with the highest PSNR (29.87). We further evaluate the performance of medical-specific neural networks trained on real and synthetic images using an unseen real-world image dataset. Our results show that the performance of models trained on synthetic images generated by the proposed method outperforms those trained with state-of-the-art standard data augmentation by 10%, leading to an overall improvement in model performances by nearly 15%.
- 1 July 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (7) , 075009
YOCO: you only calibrate once for accurate extrinsic parameter in LiDAR-camera systems
In a multi-sensor fusion system composed of cameras and light detection and ranging (LiDAR), precise extrinsic calibration contributes to the system’s long-term stability and accurate perception of the environment. However, methods based on extracting and registering corresponding points still face challenges in terms of automation and precision. This paper proposes a novel fully automatic extrinsic calibration method for LiDAR-camera systems that circumvents the need for corresponding point registration. In our approach, a novel algorithm to extract required LiDAR correspondence point is proposed. This method can effectively filter out irrelevant points by computing the orientation of plane point clouds and extracting points by applying distance- and density-based thresholds. We avoid the need for corresponding point registration by introducing extrinsic parameters between the LiDAR and camera into the projection of extracted points and constructing co-planar constraints. These parameters are then optimized to solve for the extrinsic. We validated our method across multiple sets of LiDAR-camera systems. In synthetic experiments, our method demonstrates superior performance compared to current calibration techniques. Real-world data experiments further confirm the precision and robustness of the proposed algorithm, with average rotation and translation calibration errors between LiDAR and camera of less than 0.05∘ and 0.015 m, respectively. This method enables automatic and accurate extrinsic calibration in a single one step, emphasizing the potential of calibration algorithms beyond using corresponding point registration to enhance the automation and precision of LiDAR-camera system calibration.
- 1 July 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 36 (7) , 075009
YOCO: you only calibrate once for accurate extrinsic parameter in LiDAR-camera systems
In a multi-sensor fusion system composed of cameras and light detection and ranging (LiDAR), precise extrinsic calibration contributes to the system’s long-term stability and accurate perception of the environment. However, methods based on extracting and registering corresponding points still face challenges in terms of automation and precision. This paper proposes a novel fully automatic extrinsic calibration method for LiDAR-camera systems that circumvents the need for corresponding point registration. In our approach, a novel algorithm to extract required LiDAR correspondence point is proposed. This method can effectively filter out irrelevant points by computing the orientation of plane point clouds and extracting points by applying distance- and density-based thresholds. We avoid the need for corresponding point registration by introducing extrinsic parameters between the LiDAR and camera into the projection of extracted points and constructing co-planar constraints. These parameters are then optimized to solve for the extrinsic. We validated our method across multiple sets of LiDAR-camera systems. In synthetic experiments, our method demonstrates superior performance compared to current calibration techniques. Real-world data experiments further confirm the precision and robustness of the proposed algorithm, with average rotation and translation calibration errors between LiDAR and camera of less than 0.05∘ and 0.015 m, respectively. This method enables automatic and accurate extrinsic calibration in a single one step, emphasizing the potential of calibration algorithms beyond using corresponding point registration to enhance the automation and precision of LiDAR-camera system calibration.
- 3 October 2024
- Published by Springer Nature
- p. 510-519
Realistic Surgical Image Dataset Generation Based on 3D Gaussian Splatting
- 3 October 2024
- Published by Springer Nature
- p. 510-519
Realistic Surgical Image Dataset Generation Based on 3D Gaussian Splatting