Tian Xia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tian Xia has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Ben Glocker
Department of Computing Imperial College London UK
3 shared publicationsFabio De Sousa Ribeiro
Department of Computing Imperial College London UK
3 shared publicationsAndreas Schuh
Department of Computing Imperial College London UK
2 shared publicationsEsther Puyol-Antón
Department of Computing Imperial College London UK
2 shared publicationsKersten Petersen
Heartflow, Inc Mountain View CA USA
2 shared publicationsMatthew Sinclair
Department of Computing Imperial College London UK
2 shared publications
Latest Publications
- Open Access
Segmentor-Guided Counterfactual Fine-Tuning for Locally Coherent and Targeted Image Synthesis
Counterfactual image generation is a powerful tool for augmenting training data, de-biasing datasets, and modeling disease. Current approaches rely on external classifiers or regressors to increase the effectiveness of subject-level interventions (e.g., changing the patient's age). For structure-specific interventions (e.g., changing the area of the left lung in a chest radiograph), we show that this is insufficient, and can result in undesirable global effects across the image domain. Previous work used pixel-level label maps as guidance, requiring a user to provide hypothetical segmentations which are tedious and difficult to obtain. We propose Segmentor-guided Counterfactual Fine-Tuning (Seg-CFT), which preserves the simplicity of intervening on scalar-valued, structure-specific variables while producing locally coherent and effective counterfactuals. We demonstrate the capability of generating realistic chest radiographs, and we show promising results for modeling coronary artery disease. Code: https://github.com/biomedia-mira/seg-cft.
Open AccessSegmentor-Guided Counterfactual Fine-Tuning for Locally Coherent and Targeted Image Synthesis
Counterfactual image generation is a powerful tool for augmenting training data, de-biasing datasets, and modeling disease. Current approaches rely on external classifiers or regressors to increase the effectiveness of subject-level interventions (e.g., changing the patient's age). For structure-specific interventions (e.g., changing the area of the left lung in a chest radiograph), we show that this is insufficient, and can result in undesirable global effects across the image domain. Previous work used pixel-level label maps as guidance, requiring a user to provide hypothetical segmentations which are tedious and difficult to obtain. We propose Segmentor-guided Counterfactual Fine-Tuning (Seg-CFT), which preserves the simplicity of intervening on scalar-valued, structure-specific variables while producing locally coherent and effective counterfactuals. We demonstrate the capability of generating realistic chest radiographs, and we show promising results for modeling coronary artery disease. Code: https://github.com/biomedia-mira/seg-cft.
- 20 September 2025
- Published by Springer Nature
- p. 526-536
Segmentor-Guided Counterfactual Fine-Tuning for Locally Coherent and Targeted Image Synthesis
- 20 September 2025
- Published by Springer Nature
- p. 526-536
Segmentor-Guided Counterfactual Fine-Tuning for Locally Coherent and Targeted Image Synthesis
- 3 October 2024
- Published by Springer Nature
- p. 546-556
Mitigating Attribute Amplification in Counterfactual Image Generation
- 3 October 2024
- Published by Springer Nature
- p. 546-556
Mitigating Attribute Amplification in Counterfactual Image Generation
- Open Access
Mitigating attribute amplification in counterfactual image generation
Causal generative modelling is gaining interest in medical imaging due to its ability to answer interventional and counterfactual queries. Most work focuses on generating counterfactual images that look plausible, using auxiliary classifiers to enforce effectiveness of simulated interventions. We investigate pitfalls in this approach, discovering the issue of attribute amplification, where unrelated attributes are spuriously affected during interventions, leading to biases across protected characteristics and disease status. We show that attribute amplification is caused by the use of hard labels in the counterfactual training process and propose soft counterfactual fine-tuning to mitigate this issue. Our method substantially reduces the amplification effect while maintaining effectiveness of generated images, demonstrated on a large chest X-ray dataset. Our work makes an important advancement towards more faithful and unbiased causal modelling in medical imaging.
Open AccessMitigating attribute amplification in counterfactual image generation
Causal generative modelling is gaining interest in medical imaging due to its ability to answer interventional and counterfactual queries. Most work focuses on generating counterfactual images that look plausible, using auxiliary classifiers to enforce effectiveness of simulated interventions. We investigate pitfalls in this approach, discovering the issue of attribute amplification, where unrelated attributes are spuriously affected during interventions, leading to biases across protected characteristics and disease status. We show that attribute amplification is caused by the use of hard labels in the counterfactual training process and propose soft counterfactual fine-tuning to mitigate this issue. Our method substantially reduces the amplification effect while maintaining effectiveness of generated images, demonstrated on a large chest X-ray dataset. Our work makes an important advancement towards more faithful and unbiased causal modelling in medical imaging.