SGSumit Goyal

Sumit Goyal

*This is an algorithmically generated author record based on publicly available information.

Sumit Goyal has a total of 70 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effect of Sleep and Screen Time on Neurobehavioral Problems Among School-Going Children

    by Gaurav Kulshrestha, Pranjali Dwivedi, Rahul Sinha, Sumit Goyal, Sweta Suman

    Purpose: Excess screen exposure affects children's behavior and ability to focus through multiple pathways, including the potential for sleep disturbances that negatively influence developmental outcomes. This study aimed to investigate the relationship between screen time (ST), sleep disturbances, and neurobehavioral problems in school-going children. Methods: An observational cross-sectional study was conducted on 776 children at a tertiary care hospital. Study participants were divided into two groups: pre-adolescent children (aged 6-12 years), and adolescent children (aged 12-18 years). Parents were interviewed to collect demographic information, sleep-related data, and ST patterns. Behavioral issues were assessed using the Child Behavior Checklist (CBCL). Statistical analysis involved the chi-square test and logistic regression to identify associations between variables. Results: Among the 776 participants, preadolescents exhibited longer average daily screen use (mean 6.98 hours), more frequent sleep disturbances (22.9%), and higher neurobehavioral problem scores (mean CBCL T-score 60.9) than adolescents (mean ST 6.02 hours, sleep disturbances 15.2%, CBCL score 57.8). Increased ST, frequent use of mature-rated video games, and the presence of sleep problems were each significantly associated with higher neurobehavioral problem rates, with these relationships being particularly pronounced in preadolescents. Conclusion: This study highlights an age-dependent influence of screen exposure, sleep disturbances, and mature-rated gaming content on neurobehavioral outcomes in school-going children. Preadolescents demonstrate heightened vulnerability, with greater neurobehavioral problems, more sleep disturbances, and higher exposure to problematic digital content compared to adolescents. Age-specific interventions promoting appropriate screen use and healthy sleep hygiene are essential to reduce these risks.

  • Open Access

    Efficacy of mini-scleral lenses in visual rehabilitation for corneal disorders: a prospective study

    by Jaya Kaushik, Sumit Goyal, Ankita Singh, Vipin Rana, Jitendra Kumar Singh Parihar, Alok Sati, Mayank Jhanwar

    Background: Corneal irregularities are a significant cause of visual impairment, impacting patients’ quality of life. Conventional treatment with spectacles and/or contact lenses fail to provide adequate rehabilitation in these cases. This study aimed to evaluate the efficacy and patient satisfaction with use of mini-scleral devices (MSDs) in patients with various corneal disorders including keratoconus, corneal scarring, post-corneal transplant, and post-refractive surgery. Methods: This analytical, observational, prospective study included 40 eyes of 32 patients with corneal surface irregularities and rigid gas permeable (RGP) or soft contact lenses intolerance. Comprehensive ophthalmic evaluation, including corneal topography, was performed. Primary outcomes measured were improvement in best lens-corrected visual acuity (BLCVA) by ≥ 2 lines and daily wear time of ≥ 10 h. Secondary outcomes included patient comfort, lens acceptance, and adverse events. Patients were followed up for a duration of three months. Results: MSDs significantly improved visual outcomes, with 80% of eyes achieving a BLCVA of ≥ 0.4 logMAR. Patients with keratoconus (85%) and post-refractive surgery status (100%) exhibited best visual improvement. The mean daily wear time was 12.1 ± 2.2 h. High comfort levels were reported in 26 eyes, while 12.5% of patients discontinued using the MSDs. No significant adverse events were observed. Conclusion: MSDs represent a valuable therapeutic option offering improved visual outcomes, high levels of patient satisfaction and comfort in patients with various corneal disorders. These are a good alternative for eyes not amenable to correction with glasses or contact lenses, especially in patients planned for or awaiting corneal transplant.


  • Comparison of biomicroscopic fluorescein tear breakup time with noninvasive tear breakup time in diabetic patients with dry eyes

    by Mayank Jhanwar, Sumit Goyal, Saurabh Kushwaha, Mohini Agrawal, V. K. B. Muthu Kamal, Arpit Srivastava

    Objectives: This study aimed to compare biomicroscopic fluorescein tear breakup time (TBUT) with noninvasive tear breakup time (NI-TBUT) using Sirius topography in diabetic patients with dry eyes. We evaluated the correlation between Ocular Surface Disease Index (OSDI) scores, tear film stability, and diabetes duration to assess the effectiveness of NI-TBUT as a diagnostic tool. Materials and Methods: A comparative cross-sectional observational study was conducted on 100 patients (200 eyes) diagnosed with Type II diabetes mellitus and dry eye symptoms (OSDI >23). NI-TBUT was measured using Sirius topography, followed by fluorescein TBUT assessment. Statistical analyses included paired comparisons, correlation with OSDI scores, and the effect of diabetes duration on tear film stability. Results: The mean TBUT was significantly lower than NI-TBUT in both eyes (P < 0.000). NI-TBUT values were consistently longer, indicating better tear film stability. A significant positive correlation was observed between diabetes duration and OSDI scores (r = 0.3864, P < 0.00), as well as between hemoglobin A1c levels and dry eye severity. Discussion and Conclusion: NI-TBUT provides a more stable and reliable assessment of tear film integrity than fluorescein TBUT, making it a valuable noninvasive diagnostic tool. Its integration into routine diabetic eye examinations can enhance early detection and management of dry eye syndrome in diabetic patients.


  • Anterior segment optical coherence tomography-based corneal pachymetry as a potential biomarker for diabetic keratopathy: An observational study on diabetic patients in North India

    by Jaya Kaushik, Rakesh Kumar Jha, Ankita Singh, Sumit Goyal, Vipin Rana, Jitendra Kumar Singh Parihar, Sunandan Bhatta

    Objectives: The objective of this study was to evaluate central corneal epithelial thickness (CCET) and central corneal thickness (CCT) using anterior segment optical coherence tomography (AS-OCT) in diabetic patients and assess their relationship with the duration of diabetes, tear breakup time (TBUT), and Schirmer’s test. These findings were compared with a nondiabetic population. Materials and Methods: This cross-sectional, observational study included 75 eyes from diabetic patients and 75 eyes from nondiabetic controls. CCET and CCT were measured using AS-OCT, while TBUT and Schirmer’s test were conducted to assess the dry eye status. The correlation between CCET, TBUT, and the duration of diabetes was analyzed. Results: CCET was significantly thinner in diabetic patients (47.09 ± 7.09 μm) compared to controls (50.19 ± 5.92 μm, P = 0.004), with a strong negative correlation between CCET and diabetes duration (Rs. = −0.81). TBUT was also lower in diabetics (P = 0.001), indicating a higher prevalence of dry eye. CCT differences between groups were nonsignificant (P = 0.85). Discussion and Conclusion: Baseline CCET and TBUT should be recorded during the initial evaluation of diabetic patients and monitored at regular intervals. AS-OCT-based CCET measurement could serve as a noninvasive biomarker for early detection of diabetic ocular disease progression, enabling prompt management to prevent advanced corneal complications.

  • Open Access

    Analysis of phacoemulsification surgery on quantitative variation of anterior chamber using Sirius tomogram in patients of North India

    by Jaya Kaushik, Sumit Goyal, Ankita Singh, Anushree Cm, Rishi Sharma, Meenu Dangi, Vipin Rana, Vikas Sharma

    BACKGROUND: The purpose of this study was to quantify the alterations in anterior chamber angle (ACA) parameters following phacoemulsification surgery. We also aim to assess changes in intraocular pressure (IOP) by comparing preoperative and postoperative measurements. Furthermore, the study explores potential associations between changes in ACA parameters and clinical outcomes, including IOP control. MATERIAL AND METHODS: A prospective observational study of ACA parameters among patients undergoing phacoemulsification surgery in North India. All patients were examined preoperatively and 1 month postoperatively using the Sirius tomographer to study ACA, anterior chamber depth (ACD), anterior chamber volume (ACV), central corneal thickness (CCT), and corneal volume (CV). IOP was assessed using the Goldmann applanation tonometer. This clinical study included 40 eyes of 40 patients. RESULTS: There is a statistically significant increase in mean ACA measurement from 47.27 ± 6.54° to 56.74 ± 4.72°, mean ACD from 2.76 ± 0.39 mm to 3.45 ± 0.39 mm, mean ACV from 160.47 ± 24.41 mm3 to 196.63 ± 23.63 mm3, mean CV from 52.92 ± 3.22 mm3 to 54.23 ± 2.86 mm3. The mean IOP measurement decreased from 17.03 ± 2.08 mm Hg preoperatively to 15.58 ± 2.92 mm Hg postoperatively and is statistically significant (p ≤ 0.001). CONCLUSION: The study provides valuable insights into quantifying ACA in the North Indian population using Scheimpflug corneal tomography. It shows a significant increase in ACA, ACD, ACV, and CV and a significant decrease in IOP following uneventful cataract surgery. These findings have implications for managing cataracts associated with glaucoma and other ocular conditions. Keywords: cataract phacoemulsification angle Scheimpflug Sirius+ anterior chamber tomography

  • Open Access

    Innovations in ocular drug delivery

    by Sumit Goyal, Pranjali Dwivedi, Jaya Kaushik, Mayank Jhanwar, Ankita Singh, Anushree C M

    Traditional ocular drug delivery methods via topical (eye drops and ointments) and systemic routes (oral or intravenous medications) yield suboptimal therapeutic drug concentrations intraocularly. Innovations aimed at improving the localization, duration, and efficacy of ocular drug delivery have shifted treatment paradigm by enhancing drug penetration, sustaining drug release and also enhancing patient compliance.:Aim of this review is to summarize recent advancements in ocular drug delivery systems, to evaluate their clinical effectiveness and to discuss their potential to improve clinical outcomes. The review will also identify ongoing challenges and future research avenues leading to further progress in this field.Recent advancements in ocular drug delivery systems are based on Nanotechnology-based delivery systems; Sustained-release implants and devices; Hydrogels and contact lens; Microneedle technology and Gene therapy vectors. Nanoparticles, nanomicelles, and nanoemulsions improve drug penetration and provide sustained release within ocular tissues. Biodegradable and non-biodegradable implants and devices offer prolonged drug delivery. Hydrogels and drug-embedded contact lenses improved patient comfort. Microneedle arrays enabling minimally invasive drug delivery directly to ocular tissues. Viral and non-viral vectors address underlying genetic causes in inherited retinal diseases. Traditional methods such as eye drops, ointments, and intravitreal injections have limitations, including poor bioavailability, frequent administration, and non-compliance. Emergence of novel delivery systems, including nanoparticles, microneedles, sustained-release implants, and gene therapy vectors, offers solutions to these challenges. These innovations provide controlled and sustained drug release, improved drug stability, and targeted delivery to specific ocular tissues, resulting in enhanced therapeutic outcomes and reduced side effects.


  • Open Access

    Alpha-adrenergic antagonists and iris dynamics: Challenges and solutions in cataract surgery

    by Jaya Kaushik, Rishi Sharma, Sumit Goyal, Meenu Dangi, Rakesh Kumar Jha, Ankita Singh

    Background: Alpha-1 adrenergic receptor antagonists (α1-ARAs) are frequently used in treatment of Hypertension and symptomatic benign prostatic hypertrophy (BPH). Numerous studies have demonstrated the association between α1-ARAs like Tamsulosin and increased surgical risks for patients undergoing cataract surgery. This study aims to identify and study the effects of α1-ARAs on iris parameters and the subsequent operative challenges encountered during cataract surgery. Methods: A cross-sectional, prospective study involving 30 patients on α1-ARAs planned for cataract surgery and equal number of age and sex matched controls were subjected to evaluation of changes on iris parameters and subsequent challenges in cataract surgery. Results: The study group had statistically significant lesser pupil diameter. Iris thickness at sphincter muscle region (SMR) was similar between groups (P = 0.53). Significantly lower values of iris thickness at dilator muscle region (DMR) found in treated subjects (P = < 0.001). There was statistically significant difference between DMR/SMR ratio of two groups (P < 0.001). Multiple regression analysis revealed longer duration of α1-ARAs treatment correlated with reduced DMR/SMR ratio (P = 0.001; r = 0.47). Conclusion: α1-ARAs have implications for pupil size regulation and surgical procedures involving the eye. Tamsulosin is more potent than alfuzosin in inducing IFIS. Systemic α1-ARAs lower values of DMR thickness, DMR/SMR ratio and reduces pupillary diameter. Therefore, ophthalmologists, primary care physicians, urologists, and patients should be aware of the potential difficulties that these drugs pose for cataract surgery.


  • Open Access

    Quantification of Anterior Chamber Angle in North Indian Population Using Scheimpflug-based Corneal Tomographer

    by Jaya Kaushik, Sumit Goyal, Ankita Singh, Sandeep Gupta, Jitendra Kumar Singh Parihar

    A BSTRACT: Objectives: Primary angle closure glaucoma shows faster clinical progression as compared to open-angle glaucoma. Hence, its early diagnosis is crucial so that prophylactic peripheral iridotomy can be done. The current gold standard for anterior chamber angle (ACA) assessment is gonioscopy but is invasive and requires skilled operators, limiting its widespread use. The objective of this study is to evaluate Sirius + Scheimpflug tomographer as a screening method for the diagnosis of gonioscopically narrow ACA. Materials and Methods: A comparative cross-sectional analysis of ACA and related parameters among glaucoma patients using dual Scheimpflug analyzer Sirius + was done. Sirius + measurements were correlated with gonioscopically closed angle and open angles to determine statistical significance. This clinical study included 80 eyes of 40 patients reporting to the ophthalmology department with raised intraocular pressure. Results: The mean ACA recorded for open-angle eyes was 39.05° ± 5.91° and was 25.92° ± 4.46° for narrow-angle eyes ( P < 0.0001). The Pearson correlation coefficient revealed a significant correlation of Sirius + parameters (ACA, anterior chamber volume [ACV], aqueous depth, horizontal anterior chamber diameter, and lens rise) with gonioscopically closed angles (Shaffer’s grade 2 or below) which was further confirmed by receiving operator characteristic analysis wherein areas under curve revealed excellent discriminant power of ACA, ACV, lens rise, and aqueous depth in detecting closed angles. Conclusions: Scheimpflug-based tomography offers objective measurements, enhancing the reliability of ACA evaluation. The study employed the technology to quantify the ACA and highlighted the statistically significant Sirius + parameters that can be exercised for screening and early diagnosis for patients with angle closure glaucoma.

  • Open Access

    Comparative Analysis of Postoperative Astigmatism Following Two Different Manual Methods of Corneal Marking for Toric Intraocular Lens Implantation

    by Sumit Goyal, Vivek Sharma, Gaurav Kapoor, Sagarika Patyal, Jaya Kaushik, Mayank Jhanwar, Pranjali Dwivedi

    A BSTRACT: Objectives: Astigmatism correction has become an increasingly important component of cataract surgery. The primary objective of the study is to compare the residual astigmatism after toric intraocular lens (IOL) implantation in cataract surgery using two manual methods of corneal marking. The secondary objectives are to compare postoperative uncorrected distance visual acuity (UCDVA) and accuracy of toric IOL alignment in both the groups. Materials and Methods: This was a comparative prospective analysis of postoperative refractive outcome after toric IOL implantation during cataract surgery using manual methods of corneal marking. The first group underwent slit-lamp-assisted corneal axis marking. The second group underwent preoperative reference marking with bubble marker followed by intraoperative axis marking (two-step procedure). This clinical study included 80 eyes of 74 patients undergoing cataract surgery with coexisting corneal astigmatism. Results: The mean postoperative UCDVA at postoperative day 01 for the first group was 0.295 ± 0.14 logMAR (range from 0 to 0.8 logMAR) and for the second group was 0.328 ± 0.22 logMAR (range from 0 to 1.0 logMAR). The difference was not statistically significant ( P = 0.441). The mean postoperative UCDVA at postoperative day 28 for the first group was 0.205 ± 0.13 logMAR (range from 0 to 0.6 logMAR) and for the second group was 0.283 ± 0.19 logMAR (range from 0 to 1.0 logMAR). This difference was statistically significant ( P = 0.045). Conclusions: Slit-lamp marking gave better postoperative results as compared to toric bubble marker in terms of better postoperative visual outcome and lesser mean postoperative IOL misalignment following toric IOL implantation in astigmatic patients undergoing cataract surgery.

  • Open Access

    Molecular Response Assessment with Immune Adaptive PERCIST in Lung Cancer Patients Treated with Nivolumab: Is It Better Than iRECIST?

    by Manoj Gupta, Partha S. Choudhury, Parveen Jain, Manish Sharma, Venkata P. B. Koyyala, Sumit Goyal, Chaturbhuj Agarwal, Ankush Jajodia, Sunil Pasricha, Anurag Sharma, et al.

    Aims We compared the immune response evaluation criteria in solid tumors (iRECIST) with immune adaptive positron emission tomography response criteria in solid tumors (imPERCIST) in lung cancer patients treated with nivolumab. Materials and Methods Twenty lung cancer patients underwent fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) scan at baseline (PET-0), after four cycles (PET-1) and six to eight cycles (PET-2) of nivolumab were included. Kappa coefficient (k) was derived to see the level of agreement in two response criteria. Progression-free survival (PFS) curves were computed by the Kaplan–Meier method and compared with the Log Rank test. Univariate and multivariate regression for the percentage change in the sum of diameters (SoD), standard uptake value maximum (SUVmax), sum of metabolic tumor volume (SoMTV), and sum of total lesion glycolysis (SoTLG) was computed. A p-value less than 0.05 was considered significant. Results Kappa coefficient showed a substantial level of agreement (k 0.769) in two response criteria. Mean PFS in partial response, stable disease, and progressive disease (PD) patients in iRECIST and imPERCIST was 27.3, 17.7, 4.2, and 23.3, 18.8, 3.8 months, respectively. The Kaplan–Meier method with the log rank test showed a significant difference in PFS on intracomparison within both criteria; however, it was not significant on intercomparison. On univariate analysis, the percentage change in SoD, SoMTV, SoTLG was significant. However, on multivariate analysis, only percentage change in SoD was a significant predictor. Conclusions We concluded that imPERCIST was equally effective as currently recommended criteria iRECIST for response evaluation of nivolumab in lung cancer patients.