SASalman A. Arain

Salman A. Arain

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Salman A. Arain has a total of 80 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • HydroDynamic Recanalization for Chronic Total Occlusion Percutaneous Coronary Intervention: Insights From the PROGRESS‐CTO Registry

    by Eleni Kladou, Dimitrios Strepkos, Michaella Alexandrou, Pedro E. P. Carvalho, Jaskanwal Deep Singh Sara, Khaldoon Alaswad, Mir B. Basir, Dmitrii Khelimskii, Farouc A. Jaffer, Nidal Abi Rafeh, et al.

    Background: HydroDynamic Recanalization (HDR) is a novel technique for crossing coronary chronic total occlusions (CTOs) that involves intraplaque contrast injection followed by polymer‐jacketed guidewire advancement. Aim: The aim of this study is to compare the technical and procedural outcomes, and safety of CTO PCIs performed with HDR versus (vs.) without HDR. Methods: We analyzed the baseline clinical and angiographic characteristics and outcomes of HDR‐treated patients in the multicenter PROGRESS‐CTO registry. Results: Of 1807 CTO percutaneous coronary interventions (PCIs) (1797 patients) performed in 2025, HDR was utilized in 90 (5%) cases. HDR patients had similar baseline clinical characteristics with non‐HDR patients, although a history of prior PCI was more common among HDR patients (75.3% vs. 60.2%, p = 0.006). HDR‐treated patients were less likely to have interventional collaterals (38.2% vs. 55.4%, p = 0.002) but more likely to have in‐stent restenosis (35.6% vs. 14.9%, p < 0.001). HDR cases had higher prevalence of blunt/no stump (62.2% vs. 50.1%, p = 0.025), smaller lesion diameter (2.88 ± 0.67 vs. 3.03 ± 0.55, p = 0.011), and less frequently side branch at the proximal cap (43.7% vs. 64.0%, p < 0.001). They had higher J‐CTO (2.63 ± 1.10 vs. 2.29 ± 1.14, p = 0.006), PROGRESS‐CTO (1.33 ± 1.02 vs. 1.13 ± 0.93, p = 0.048) and PROGRESS‐CTO MACE (3.06 ± 1.55 vs. 2.65 ± 1.67, p = 0.014) scores. Antegrade wiring was both the first and the most successful crossing strategy in both groups. HDR cases had significantly longer procedural (131 [107, 174] vs. 109 [74, 151] min, p < 0.001), fluoroscopy (48 [34, 70] vs. 39 [25, 61]) min, p = 0.001), and crossing (39 [22, 86] vs. 25 [11, 56] min, p < 0.001) time compared with non‐HDR cases. Technical success was lower in HDR patients (80.0% vs. 88.5%, p = 0.024), while MACE (1.1% vs. 2.6%, p = 0.7) was not different between the two groups. Conclusions: HDR was performed in 5% of CTO PCIs in 2025, in more complex lesions and was associated with lower technical success but similar MACE compared with patients who underwent CTO PCI without HDR.

  • Open Access

    Rotational Atherectomy Through Guide Extension Catheters: Indications, Technique, and Limitations

    by Evandro Martins Filho, Thomas E. Kaier, M. Bilal Iqbal, Rodrigo Vugman Wainstein, Guilherme Pinheiro Machado, Marco Wainstein, Ricardo F. O. Suruagy Motta, Salman A. Arain, Marielle Rodrigues Martins, Konstantin Schwarz

    Rotational atherectomy (RA) is an established technique for the treatment of heavily calcified coronary artery disease. Severe coronary calcification remains a frequent cause of procedural difficulty and device delivery failure during complex percutaneous coronary intervention (PCI). Delivery of the atherectomy burr to the target lesion may be particularly challenging in the presence of limited guide support, proximal vessel tortuosity, or unfavorable coronary anatomy that restricts safe access to distal calcified segments. Guide extension catheters (GECs) are widely used to enhance guide support and improve coaxial alignment during complex PCI. However, their use in combination with RA represents an advanced and selectively applied strategy that is not routinely addressed in conventional atherectomy training and is often avoided because of concerns regarding device interaction and difficulties during burr delivery and retrieval. Despite increasing anecdotal use in complex PCI, the technical principles and procedural safety considerations of performing RA through GECs remain insufficiently described in the literature. This review provides a focused technical overview of RA performed through GECs. We summarize the rationale for this approach, describe key technical considerations including device compatibility and burr advancement strategies, and discuss practical measures to minimize procedural complications. In addition, we outline clinical scenarios in which this technique may be beneficial, as well as situations where it should be avoided. Rather than advocating routine use, this review aims to define the role of guide extension–facilitated RA as a selective strategy for highly complex coronary anatomies.

  • Intravascular Ultrasound Findings Associated With Hydrodynamic Contrast Recanalization (HDR) of Coronary Chronic Total Occlusions

    by Salman A. Arain, Angelo Nascimbene, Akshitha Yarrabothula, Jaime Hudson, Emmanouil S. Brilakis, Antonio Colombo, Lorenzo Azzalini, M. Bilal Iqbal, Bernardo Cortese, Yukata Tadano, et al.

    Background: Hydrodynamic contrast recanalization (HDR) is a novel technique to facilitate wire crossing during chronic total occlusion (CTO) percutaneous coronary interventions (PCI). The mechanisms underlying HDR have not been fully described. Aims: To investigate the impact of HDR on plaque morphology and wire tracking during CTO PCI using intravascular ultrasound (IVUS) imaging. Methods: We identified 35 patients who underwent successful HDR and IVUS‐guided CTO PCI at our institution between January 2023 and December 2024. We collected the following from IVUS images: wire position (intraplaque vs. extraplaque) within the CTO segment, plaque morphology, and evidence of vascular injury (intramural hematoma or dissection). Results: Immediate post‐HDR IVUS images were available for analysis in all 35 patients. IVUS imaging revealed intraplaque guidewire crossing in 91% ( n = 32) of cases. Intraplaque speckling, which we have termed the “Starry Sky” sign, was observed in 24 cases (68%), and intramural hematoma was found in 11 cases (31%). Four dissections were detected: two precluded direct distal wire re‐entry necessitating the use of non‐HDR techniques (94% technical success). The overall procedural success rate was 100%, and there were no PCI‐related complications (perforation, myocardial infarction, or death). Conclusions: HDR is a novel CTO PCI technique that appears to facilitate intraplaque wire crossing without causing significant vessel injury. The presence of speckled plaque by IVUS is a unique feature of HDR that may suggest a mechanism underlying this technique. Additional studies are needed to confirm these findings.


  • Open Access

    Aligning Surgical Decisions With Older Adults' Outcome Goals

    by Aanand D. Naik, Margaret L. Schwarze, Jack Banks, Suha Soni, Salman A. Arain, Parag Goyal, Daniel D. Matlock, Rachel Lampert, Mary E. Tinetti

  • HydroDynamic contrast Recanalization (HDR): Description of a new crossing technique for coronary chronic total occlusions

    by Mauro Carlino, Angelo Nascimbene, Emmanouil S. Brilakis, Akshitha Yarrabothula, Antonio Colombo, Sunao Nakamura, Lorenzo Azzalini, Bashir Hanif, M. Bilal Iqbal, Salman A. Arain

    Background: Intraplaque delivery of contrast has been utilized during percutaneous coronary interventions (PCI) of chronic total occlusions (CTO) to delineate anatomy and to facilitate wire crossing. Its utility as a tool to accomplish primary crossing of CTOs has not been described or validated.Aims: We describe a new technique leveraging the diagnostic and therapeutic roles of intraplaque contrast injection to accomplish primary crossing of CTOs: HydroDynamic contrast Recanalization (HDR).Methods: HDR is an antegrade crossing method for coronary CTOs based on the synergistic use of contrast microinjections and polymer jacketed wires. We present a retrospective, first‐in‐man, case series utilizing HDR for CTO PCI in patients with favorable CTO anatomy (visible proximal segment and identifiable distal target). The primary outcome was procedural success. The secondary outcome was any procedural complications.Results: A total of 43 patients with 45 CTOs underwent CTO PCI with HDR. Mean patient age was 64.3 ± 11 years. The mean Japanese CTO and PROGRESS CTO scores were 2.3 ± 0.7 and 1.8 ± 0.7, respectively. CTO complexity was high, with an ambiguous or blunt cap in 34 occlusions (76%); lesion length ≥ 20 mm in 27 occlusions (60%); and moderate/heavy calcification in 36 occlusions (80%). Procedural success using HDR was 100%. There were no complications.Conclusions: This study shows the utility of HDR in CTO PCI. HDR appears to be a safe and promising new contrast‐based primary crossing technique in selected patients. This strategy warrants further evaluation in larger prospective studies.


  • Open Access

    D-18 | Mortality Impact of Cardiac Index Prior To Revascularization in Patients With Viable Ischemic Cardiomyopathy

    by Jawad Chohan, Andrew Huynh, Salman A. Arain, Abhijeet Dhoble, Sukhdeep Singh Basra, Sachin Kumar, Angelo Nascimbene, Marwan Jumean, Biswajit Kar

  • Open Access

    C-38 | Improving TAVR Procedural Volume Disparities Among Active Cancer: Propensity Score and Machine Learning Case-control Analysis of 101 Million+ Hospitalizations From 2016-2018

    by Jin Wan Kim, Dominique J. Monlezun, Kevin A. Honan, Cesar A. Simbaqueba Clavijo, Siddharth Chauhan, Andrew Badalamenti, Victor Liu, Awad Javaid, Dinu-Valentin V. Balanescu, Nicolas Palaskas, et al.

  • Open Access

    B-7 | Impella Has Greater Mortality Benefit For Patients With Versus Without Cancer: Machine Learning Supported Propensity Score Case-control Analysis of 101 Million+ Hospitalizations From 2016-2018

    by Kevin A. Honan, Dominique J. Monlezun, Andrew Badalamenti, Jin Wan Kim, Victor Liu, Awad Javaid, Siddharth Chauhan, Cesar A. Simbaqueba Clavijo, Dinu-Valentin V. Balanescu, Nicolas Palaskas, et al.

  • Successful endovascular extraction of newer generation Angio-Seal collagen plug and anchor after acute embolization

    by Nidal Abi Rafeh, Faisal B Saiful, Georges Khoueiry, Mohammad Zgheib, Salman Arain

    A 75-year-old woman with past medical history of coronary bypass, atrial fibrillation, mitral valve repair undergoes percutaneous coronary intervention of left circumflex artery with a drug eluting stent. An Angio-Seal vascular closure device was used post procedure to obtain hemostasis. Shortly after deployment, frank bleeding was observed necessitating manual compression at the arteriotomy site. After hemostasis was achieved, the right lower extremity was found to be pale, bluish with feeble pulses. Doppler ultrasound was emergently performed revealing decreased blood flow after mid superficial femoral artery (SFA) and an echo lucent object lodged luminally in the SFA. Patient was urgently taken to the vascular laboratory where an Angio-Seal device, including the collagen plug and anchor, was successfully removed endovascularly patient made full recovery and was discharged home the following day.