Christelle Marquié
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Christelle Marquié has a total of 144 co-authors. Here are the top co-authors by number of shared publications:
- Pascal Defaye
University Hospital of Grenoble-Alpes, 38043 Grenoble, France
4 shared publications - Eloi Marijon
Division of Cardiology, European Georges Pompidou Hospital, Paris, France
3 shared publications - Alexis Mechulan
Ramsay Santé, Hôpital Privé Clairval, Service Cardiologie-Rythmologie, Marseille, France
2 shared publications - Antoine Da Costa
Department of Cardiology Jean Monnet University Saint‐Etienne France
2 shared publications - Christophe Leclercq
University of Rennes, Rennes, France
2 shared publications - Jean Luc Pasquier
Department of Cardiology, University Hospital of Montpellier , Montpellier
2 shared publications
Latest Publications
- Open Access
- 12 June 2026
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 28 (7)
Early complications and long-term outcome of patients treated with a Subcutaneous Cardioverter-Defibrillator: temporal trends and clinical implications of the anesthetic strategies adopted at implant
Background and Aims: Subcutaneous implantable cardioverter defibrillator (S-ICD) therapy is well-established therapy for the prevention of sudden cardiac death. Although general anesthesia (GA) was initially advocated for implantation, non-GA has emerged as a feasible alternative in clinical practice. This study evaluated the early and long-term outcomes associated with anesthetic modality during S-ICD implantation procedures. Methods: The HONEST study nationwide, single-arm, observational cohort included all patients implanted with an S-ICD (EMBLEM™, Boston Scientific) in France between 2012 and 2019. GA was characterized by controlled unconsciousness with airway management, while non-GA included all alternative techniques. Results: Among 4,924 patients, 1,041 (21.1%) underwent non-GA. The proportion of non-GA use increased from 2.5% to 26.9% between 2012 and 2019 (p<0.001). Patients implanted with non-GA modality tended to be older (51 ± 14 vs. 50 ± 15 years), had lower left ventricular ejection fraction (41±16 vs. 43±17%), and fewer secondary prevention indications (33 vs. 38%) (all p0.1). Conclusion: Anesthesia strategy used for S-ICD implantation was not associated with poorer short- or long-term clinical outcomes, supporting non–general anesthesia as a feasible alternative in appropriately selected patients.
- 12 June 2026
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 28 (7)
Open AccessEarly complications and long-term outcome of patients treated with a Subcutaneous Cardioverter-Defibrillator: temporal trends and clinical implications of the anesthetic strategies adopted at implant
Background and Aims: Subcutaneous implantable cardioverter defibrillator (S-ICD) therapy is well-established therapy for the prevention of sudden cardiac death. Although general anesthesia (GA) was initially advocated for implantation, non-GA has emerged as a feasible alternative in clinical practice. This study evaluated the early and long-term outcomes associated with anesthetic modality during S-ICD implantation procedures. Methods: The HONEST study nationwide, single-arm, observational cohort included all patients implanted with an S-ICD (EMBLEM™, Boston Scientific) in France between 2012 and 2019. GA was characterized by controlled unconsciousness with airway management, while non-GA included all alternative techniques. Results: Among 4,924 patients, 1,041 (21.1%) underwent non-GA. The proportion of non-GA use increased from 2.5% to 26.9% between 2012 and 2019 (p<0.001). Patients implanted with non-GA modality tended to be older (51 ± 14 vs. 50 ± 15 years), had lower left ventricular ejection fraction (41±16 vs. 43±17%), and fewer secondary prevention indications (33 vs. 38%) (all p0.1). Conclusion: Anesthesia strategy used for S-ICD implantation was not associated with poorer short- or long-term clinical outcomes, supporting non–general anesthesia as a feasible alternative in appropriately selected patients.
- Open Access
- 25 April 2026
- Published by Wolters Kluwer Health in Circulation
- Vol. 154 (6) , 520-531
Subcutaneous Defibrillator Implantation With or Without Defibrillation Test: The Primary Results of the Randomized PRAETORIAN-DFT Trial
Background: To improve survival in patients at risk of sudden cardiac death, subcutaneous ICDs (S-ICDs) require optimal implant positioning for effective shocks. Defibrillation (DF) testing is recommended but carries serious risks. The PRAETORIAN score predicts defibrillation outcomes based on chest X-rays. The PRAETORIAN-DFT trial evaluated whether omission of DF testing guided by the PRAETORIAN score is non-inferior for first-shock efficacy. Methods: In this multinational trial, S-ICD patients from 37 centers were randomized to DF testing or no DF testing. In the No-DF testing group, the PRAETORIAN score was evaluated before discharge. The primary endpoint was failed first shock for spontaneous ventricular arrhythmias, as a surrogate for defibrillation success, tested for non-inferiority with a 3% absolute risk margin. Secondary endpoints included mortality, potential DF testing-related complications, and S-ICD revisions. Results: The included 965 patients (No-DF testing, n=483;DF testing, n=482) were followed for a median of 41 months. Failed first shock for spontaneous ventricular arrhythmia occurred in 1.7% of the No-DF testing group versus 2.3% of the DF testing group (–0.6%, 95% CI [ –2.6 to 1.4]; p<0.001). There were no significant differences in all-cause mortality (HR 0.9 [95% CI 0.6–1.4]) or arrhythmic death (HR 0.4 [95% CI 0.04–3.4]). Potential DF testing-related complications occurred in 1.7% in the DF testing group. Postoperative S-ICD revisions due to inadequate positioning were identical between groups (n=2 each). Conclusions: PRAETORIAN score–guided omission of DF testing- after S-ICD implantation did not increase the risk of failed first shocks for spontaneous ventricular arrhythmias and reduced procedural risk without increasing S-ICD revisions. (Funded by Boston Scientific; PRAETORIAN-DFT).
- 25 April 2026
- Published by Wolters Kluwer Health in Circulation
- Vol. 154 (6) , 520-531
Open AccessSubcutaneous Defibrillator Implantation With or Without Defibrillation Test: The Primary Results of the Randomized PRAETORIAN-DFT Trial
Background: To improve survival in patients at risk of sudden cardiac death, subcutaneous ICDs (S-ICDs) require optimal implant positioning for effective shocks. Defibrillation (DF) testing is recommended but carries serious risks. The PRAETORIAN score predicts defibrillation outcomes based on chest X-rays. The PRAETORIAN-DFT trial evaluated whether omission of DF testing guided by the PRAETORIAN score is non-inferior for first-shock efficacy. Methods: In this multinational trial, S-ICD patients from 37 centers were randomized to DF testing or no DF testing. In the No-DF testing group, the PRAETORIAN score was evaluated before discharge. The primary endpoint was failed first shock for spontaneous ventricular arrhythmias, as a surrogate for defibrillation success, tested for non-inferiority with a 3% absolute risk margin. Secondary endpoints included mortality, potential DF testing-related complications, and S-ICD revisions. Results: The included 965 patients (No-DF testing, n=483;DF testing, n=482) were followed for a median of 41 months. Failed first shock for spontaneous ventricular arrhythmia occurred in 1.7% of the No-DF testing group versus 2.3% of the DF testing group (–0.6%, 95% CI [ –2.6 to 1.4]; p<0.001). There were no significant differences in all-cause mortality (HR 0.9 [95% CI 0.6–1.4]) or arrhythmic death (HR 0.4 [95% CI 0.04–3.4]). Potential DF testing-related complications occurred in 1.7% in the DF testing group. Postoperative S-ICD revisions due to inadequate positioning were identical between groups (n=2 each). Conclusions: PRAETORIAN score–guided omission of DF testing- after S-ICD implantation did not increase the risk of failed first shocks for spontaneous ventricular arrhythmias and reduced procedural risk without increasing S-ICD revisions. (Funded by Boston Scientific; PRAETORIAN-DFT).
- Open Access
- 11 November 2025
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 27 (12)
Micra leadless pacemaker revisions: incidence, characteristics, and outcomes from a multicentre French cohort
Aims: Leadless pacemakers (LLPs) offer a valuable option for selected patients requiring ventricular pacing. However, data on revision procedures—defined as any intervention on an implanted LLP to correct dysfunction or upgrade the system, with or without removal—remain scarce. This study aimed to evaluate the real-world incidence, characteristics, and outcomes of LLP revisions, with particular emphasis on the feasibility and safety of removal. Methods and results: This multicentre retrospective study involved 46 French centres performing LLP implantations between 2015 and 2023. Among 8994 Micra LLPs implanted, 100 revision procedures (1.1%) were performed in 100 patients, including 73 Micra VR and 27 Micra AV devices, at a median follow-up of 229 (68.5–629.8) days. Seventy revisions were managed without device removal, while 30 involved removal. Revision indications included device upgrade (55%), high pacing threshold (33%), battery depletion (3%), ventricular arrhythmias (3%), and miscellaneous causes (6%). No significant differences were observed in pacing indications, implantation characteristics, or initial device indication between the two groups. Revisions occurred significantly earlier in the removal group than in the group without removal [median 81.5 (8–211.5) days, vs. 334 (130.25–882.5) days, P < 0.001], with 80% occurring within 1 year. Device removal was successful in 97% of cases (one failure at 157 days of follow-up), with no major complications reported. Conclusion: LLP revisions are infrequent and predominantly managed without device removal. However, given the high procedural success rate and the low complication rate, device removal appears to be underutilized and should be considered more frequently on a case-by-case basis.
- 11 November 2025
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 27 (12)
Open AccessMicra leadless pacemaker revisions: incidence, characteristics, and outcomes from a multicentre French cohort
Aims: Leadless pacemakers (LLPs) offer a valuable option for selected patients requiring ventricular pacing. However, data on revision procedures—defined as any intervention on an implanted LLP to correct dysfunction or upgrade the system, with or without removal—remain scarce. This study aimed to evaluate the real-world incidence, characteristics, and outcomes of LLP revisions, with particular emphasis on the feasibility and safety of removal. Methods and results: This multicentre retrospective study involved 46 French centres performing LLP implantations between 2015 and 2023. Among 8994 Micra LLPs implanted, 100 revision procedures (1.1%) were performed in 100 patients, including 73 Micra VR and 27 Micra AV devices, at a median follow-up of 229 (68.5–629.8) days. Seventy revisions were managed without device removal, while 30 involved removal. Revision indications included device upgrade (55%), high pacing threshold (33%), battery depletion (3%), ventricular arrhythmias (3%), and miscellaneous causes (6%). No significant differences were observed in pacing indications, implantation characteristics, or initial device indication between the two groups. Revisions occurred significantly earlier in the removal group than in the group without removal [median 81.5 (8–211.5) days, vs. 334 (130.25–882.5) days, P < 0.001], with 80% occurring within 1 year. Device removal was successful in 97% of cases (one failure at 157 days of follow-up), with no major complications reported. Conclusion: LLP revisions are infrequent and predominantly managed without device removal. However, given the high procedural success rate and the low complication rate, device removal appears to be underutilized and should be considered more frequently on a case-by-case basis.
- 19 June 2025
- Published by Elsevier in Archives of Cardiovascular Diseases
- Vol. 118 (11) , 595-604
Long-term risk of ventricular arrhythmia in dilated cardiomyopathy by response to cardiac resynchronization therapy
- 19 June 2025
- Published by Elsevier in Archives of Cardiovascular Diseases
- Vol. 118 (11) , 595-604
Long-term risk of ventricular arrhythmia in dilated cardiomyopathy by response to cardiac resynchronization therapy
- Open Access
- 4 October 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (11)
Multipoint pacing is associated with improved prognosis and cardiac resynchronization therapy response: MORE-CRT MPP randomized study secondary analyses
Aims: Cardiac resynchronization therapy (CRT) via biventricular (BIV) pacing is indicated in patients with heart failure (HF), reduced ejection fraction, and prolonged QRS duration. Quadripolar leads and multipoint pacing (MPP) allow multiple left ventricle (LV) sites pacing. We aimed to assess the clinical benefit of MPP in patients who do not respond to standard BIV pacing. Methods and results: Overall, 3724 patients were treated with standard BIV pacing. After 6 months, 1639 patients were considered as CRT non-responders (echo-measured relative reduction in LV end-systolic volume (LVESV) < 15%) and randomized to MPP or BIV. We analysed 593 randomized patients (291 MPP, 302 BIV), who had BIV pacing >97% of the time before randomization and complete 12 months of clinical and echocardiographic data. The endpoint composed of freedom from cardiac death and HF hospitalizations and by LVESV relative reduction ≥15% between randomization and 12 months occurred more frequently in MPP [96/291 (33.0%)] vs. BIV [71/302 (23.5%), P = 0.0103], which was also confirmed at multivariate analysis (hazard ratio = 1.55, 95% confidence interval = 1.02–2.34, P = 0.0402 vs. BIV). HF hospitalizations occurred less frequently in MPP [14/291 (4.81%)] vs. BIV [29/302 (9.60%), incidence rate ratio = 50%, P = 0.0245]. Selecting patients with a large (>30 ms) dispersion of interventricular electrical delay among the four LV lead dipoles, reverse remodelling was more frequent in MPP [18/51 (35.3%)] vs. BIV [11/62 (17.7%), P = 0.0335]. Conclusion: In patients who do not respond to standard CRT despite the high BIV pacing percentage, MPP is associated with lower occurrence of HF hospitalizations and higher probability of reverse LV remodelling compared with BIV pacing.
- 4 October 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (11)
Open AccessMultipoint pacing is associated with improved prognosis and cardiac resynchronization therapy response: MORE-CRT MPP randomized study secondary analyses
Aims: Cardiac resynchronization therapy (CRT) via biventricular (BIV) pacing is indicated in patients with heart failure (HF), reduced ejection fraction, and prolonged QRS duration. Quadripolar leads and multipoint pacing (MPP) allow multiple left ventricle (LV) sites pacing. We aimed to assess the clinical benefit of MPP in patients who do not respond to standard BIV pacing. Methods and results: Overall, 3724 patients were treated with standard BIV pacing. After 6 months, 1639 patients were considered as CRT non-responders (echo-measured relative reduction in LV end-systolic volume (LVESV) < 15%) and randomized to MPP or BIV. We analysed 593 randomized patients (291 MPP, 302 BIV), who had BIV pacing >97% of the time before randomization and complete 12 months of clinical and echocardiographic data. The endpoint composed of freedom from cardiac death and HF hospitalizations and by LVESV relative reduction ≥15% between randomization and 12 months occurred more frequently in MPP [96/291 (33.0%)] vs. BIV [71/302 (23.5%), P = 0.0103], which was also confirmed at multivariate analysis (hazard ratio = 1.55, 95% confidence interval = 1.02–2.34, P = 0.0402 vs. BIV). HF hospitalizations occurred less frequently in MPP [14/291 (4.81%)] vs. BIV [29/302 (9.60%), incidence rate ratio = 50%, P = 0.0245]. Selecting patients with a large (>30 ms) dispersion of interventricular electrical delay among the four LV lead dipoles, reverse remodelling was more frequent in MPP [18/51 (35.3%)] vs. BIV [11/62 (17.7%), P = 0.0335]. Conclusion: In patients who do not respond to standard CRT despite the high BIV pacing percentage, MPP is associated with lower occurrence of HF hospitalizations and higher probability of reverse LV remodelling compared with BIV pacing.