EREfraín Dueñas Reyes

Efraín Dueñas Reyes

*This is an algorithmically generated author record based on publicly available information.

Efraín Dueñas Reyes has a total of 52 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Frequency-Dependent Cable Modeling for Power-Loss and Voltage-Drop Assessment in Wind Farm Collection Networks: A Tehuantepec Case Study

    by Ana Karen López González, Reynaldo Iracheta Cortez, Gregorio Martínez Reyes, Efraín Dueñas Reyes

    Accurate representation of frequency-dependent cable parameters is essential for evaluating power losses and series-voltage effects in medium-voltage wind-farm collection networks. This paper develops a MATLAB-based electromagnetic framework that derives frequency-dependent series-impedance (Z) and shunt-admittance (Y) matrices for underground cables, including conductor skin and proximity effects and earth-return impedance. Four earth-return formulations—Saad–Gaba–Giroux, Wedepohl series, Wedepohl, and infinite-earth—are implemented and benchmarked against RSCAD from 10 Hz to 1 MHz. The AC series parameters evaluated at 60 Hz are applied to a 7.5 MW wind farm in the Isthmus of Tehuantepec, Oaxaca, Mexico, comprising five 1.5 MW turbines connected at 13.8 kV through two radial underground circuits. The Saad–Gaba–Giroux and Wedepohl-series formulations provide the closest agreement with the RSCAD reference. At a power factor of 0.9, the simplified DC core-resistance baseline underestimates active-power losses by 34.35% in Circuit 1 and 42.83% in Circuit 2 relative to the 60 Hz AC series-resistance model. At rated turbine output and the same power factor, the accumulated AC series-voltage indicators at the farthest turbine are 0.17% and 0.38%, compared with 0.11% and 0.20% using core-only DC resistance. These indicators do not represent terminal-voltage magnitudes, which require an AC network power-flow calculation. A component-level analysis for Circuit 1 identifies the core conductor as the dominant contributor to active-power dissipation, followed by the earth-return path and metallic sheath. An annual economic evaluation yields similar project-level financial indicators for the AC and DC representations, while a parametric resistance sensitivity analysis shows decreasing profitability and longer investment recovery periods as AC cable resistance increases. The frequency sweep validates the cable-parameter formulations; their application to electromagnetic-transient simulations remains future work.

  • Open Access

    ENHANCING SOCIAL IMPACT THROUGH AI: CNN-BASED EARLY MELANOMA DETECTION FOR IMPROVING SKIN CANCER DIAGNOSTICS AND HEALTHCARE ACCESS

    by Ricardo Carreño-Aguilera, Julián Patiño-Ortiz, Miguel Patiño-Ortiz, Verónica Aguilar-Esteva, Adán Acosta-Banda, Sergio Juárez-Vázquez, Efraín Dueñas-Reyes

    Skin cancer, particularly melanoma, remains a critical global health challenge where early detection significantly improves patient survival and reduces healthcare costs. In response to this need, this study presents a deep learning–based approach to transforming skin cancer diagnosis through accessible, accurate automated detection. A convolutional neural network (CNN) architecture with YOLO11 was developed and evaluated to improve melanoma classification in dermatological images. To further enhance diagnostic reliability, an image preprocessing stage was implemented to remove artifacts such as hair, thereby improving overall image quality and classification performance. The proposed model achieved 90% accuracy, with strong sensitivity and specificity, demonstrating its effectiveness in distinguishing benign from malignant lesions. Beyond technical performance, this work highlights the potential of CNN to expand access to early melanoma detection, particularly in resource-limited settings where specialist care may be scarce. By enabling faster, more cost-effective, and more reliable screening, this approach helps reduce diagnostic delays, optimize healthcare resources, and ultimately improve patient outcomes and quality of life. These results support the continued development of AI-driven tools as scalable solutions for equitable and impactful healthcare delivery.

  • Open Access

    A Systematic Design Methodology for Electromagnetic Brakes Applied to Low-Power Wind Turbines Using Analytical Modeling, Numerical Validation, and Experimental Verification

    by Enriquez Santiago, Jesús Antonio, Jiménez Velázquez, Alan de Jesús, Antonio Verde Añorve, Acosta Banda, Adán, Dueñas Reyes, Efraín, Sánchez Albores, et al.

    Low-power wind turbines require reliable braking systems to ensure safe operation during emergency conditions, maintenance procedures, and high wind speeds. Among the available alternatives, eddy-current electromagnetic brakes offer an attractive solution because they operate without mechanical contact, thereby reducing component wear and maintenance requirements compared with conventional braking systems. However, existing studies have primarily focused on the analysis of electromagnetic behavior, the optimization of specific configurations, or industrial applications, while relatively few have addressed a comprehensive methodology for the design and experimental validation of electromagnetic braking systems for low-power wind turbines. This study proposes a reproducible design methodology for an eddy-current electromagnetic brake intended for a 1 kW wind turbine. The proposed methodology integrates the definition of design requirements, the development of an analytical model for electromagnetic sizing, three-dimensional finite element analysis (FEA), and the experimental validation of a prototype manufactured according to the obtained design parameters. The proposed methodology was assessed through three complementary validation stages: analytical modeling, finite element simulation, and experimental testing using a dedicated test bench. The comparison of the obtained results demonstrated good agreement among the analytical predictions, numerical simulations, and experimental measurements, with a relative difference of 1.18 % between the magnetic flux density predicted by the analytical model and that obtained from the finite element analysis. Furthermore, the developed prototype successfully achieved complete rotor stoppage under the prescribed design conditions, confirming the effectiveness of the proposed braking system. The main contribution of this work lies not only in the development of an electromagnetic braking device but also in the formulation and validation of a systematic design methodology that integrates analytical modeling, numerical validation, and experimental verification into a unified design framework. The proposed methodology provides a reproducible approach for the development of electromagnetic brakes for low-power wind turbines and establishes a foundation for future protection strategies, speed regulation systems, and scaling to higher-power wind energy applications.

  • Open Access

    A Symmetric Variable Gain for a Sliding Mode Controller Applied to a Power Converter System in a Small Wind Turbine

    by Eduardo Campos-Mercado, Jonathan Benitez-Ovando, Efraín Dueñas-Reyes, Isaac Montoya-De Los Santos, Hugo Francisco Abundis-Fong, Adán Acosta-Banda, Emmanuel Hernández-Mayoral

    Interest in wind energy systems of different power ratings has increased significantly in recent years; however, low-power wind turbines are particularly sensitive to wind gust disturbances, which strongly affect their power electronic systems. In this work, a control strategy is proposed for regulating the output voltage of a buck converter integrated into a small wind turbine. To this end, a symmetric variable gain is incorporated into the classical sliding mode control framework, enabling the controller to dynamically adjust the control effort according to the operating conditions. The main objective of the proposed approach is to mitigate output voltage fluctuations induced by Extreme Operating Gusts (EOGs), which have a more pronounced impact on low-power wind turbines. The effectiveness of the proposed controller is validated through both simulation and experimental results.

  • Open Access

    Inversores Fotovoltaicos Conectados a la Red Eléctrica para Análisis Supra-Armónico

    by E. Hernández-Mayoral, E. Dueñas-Reyes, J.A. Enríquez-Santiago, G. Martínez-Reyes, J.P. Marvens, S. Juárez-Vázquez, I.G. Ortiz-Jiménez

    Las emisiones de alta frecuencia, conocidas como supraarmónicas, proliferan en las redes de baja y media tensión debido al creciente uso de tecnologías que generan distorsiones en el rango de 2 kHz a 150 kHz. Las consecuencias de este fenómeno son interferencias con los componentes de la fuente de alimentación y los equipos del usuario final. Por lo tanto, es imperativo establecer directrices y normativas que limiten la cantidad de emisiones supraarmónicas que se inyectan en la red eléctrica provenientes de los sistemas fotovoltaicos (SFVs) en el contexto del cambio climático. El objetivo de este trabajo es analizar las emisiones de dos inversores FVs presentes en una red eléctrica. Este estudio además examina señales reales de SFVs, que presentan emisiones de banda estrecha, banda ancha y variables en el tiempo. Este artículo concluye enfatizando la necesidad de regulaciones específicas para altas frecuencia, a la vez que proporciona indicaciones para futuras investigaciones.

  • Open Access

    Enhancing the Reliability of Back-to-Back Converters in Small Wind Turbines: A Comprehensive Robust Stability Study of NL-PI Control Under Extreme Operating Gusts

    by Efraín Dueñas-Reyes, O. A. Jaramillo, E. Campos Mercado, Emmanuel Hernández-Mayoral, Daniel Pacheco-Bautista

    The reliability of Wind Energy Conversion Systems (WECSs) is frequently limited by failures in Back-to-Back Power Converters (BTB-PCs), particularly within the Rotor-Side Converter (RSC) switches, which are subjected to electrical and thermal stresses induced by extreme wind gusts. This study investigates the most intense Extreme Operating Gust (EOG) recorded in 2018 at La Ventosa, Oaxaca, Mexico, using a small-scale, grid-connected WECS based on a Doubly Fed Induction Generator (DFIG) and employing classical vector control. This study confirms that such extreme wind events can cause power quality disturbances–namely low-frequency overcurrents in the RSC and electrical flicker on the DC-bus–that have been shown in the literature to accelerate switch degradation. To address these issues, a vector control strategy employing Nonlinear Proportional-Integral (NL-PI) controllers is proposed, replacing Conventional Proportional-Integral (CPI) controllers. Validation through robust stability analysis, utilizing unstructured uncertainty models and MATLAB®'s stability margin analysis, indicates that NL-PI controllers achieve stability margins exceeding unity, while CPI controllers fall below this threshold, suggesting a higher susceptibility to instability. Sensitivity analysis highlights frequency-dependent gain uncertainty ($\delta$) as the primary factor affecting robustness. Overall, the results demonstrate that NL-PI-based vector control markedly improves converter resilience, providing a cost-effective solution for WECSs operating in gust-prone environments.


  • Open Access

    Detection, Taxonomic Characterization, and Modeling of Extreme Operational Gusts in La Ventosa, Oaxaca, Mexico

    by Ángel D. J. Guillén-Olivera, Efraín Dueñas-Reyes, Emmanuel Hernández-Mayoral, Isaac Montoya De Los Santos, Ricardo Carreño-Aguilera, O. A. Jaramillo

    Extreme Operational Gusts (EOGs) are critical for assessing the effects of extreme winds on Wind Energy Conversion Systems (WECSs). In regions like La Ventosa, Oaxaca, Mexico—characterized by strong and frequent gusts—the performance and reliability of low-power WECSs can be severely impacted. Traditionally, EOG effects have been analyzed using mathematical models from the IEC 61400-2 standard, which assumes a symmetric gust taxonomy. However, field data have revealed inconsistencies with this model, leading to the development of new asymmetrical taxonomies, such as Manwell’s. This study presents a taxonomic characterization of EOGs in La Ventosa using 1 Hz wind speed data collected over one year (December 2017–November 2018), during which 1655 events were detected. A dedicated detection method was implemented to capture gusts with amplitudes and durations exceeding the IEC range, allowing systematic classification of previously unrecognized patterns. Based on these results, a new taxonomy and a mathematical model were developed to simulate any identified gust. These tools provide more realistic simulations for improving WECS protection under extreme conditions. The analysis shows that Manwell’s taxonomy represents 50.39% of events, the proposed classification 37.04%, and IEC 61400-2 only 12.57%, underscoring its limited applicability to high-wind sites like La Ventosa.

  • Open Access

    Extreme Operating Gusts Detection and Their Effects on Back-to-Back Converter Reliability in Small Wind Turbines

    by Efraín Dueñas-Reyes, O. A. Jaramillo, E. Campos Mercado, Emmanuel Hernández-Mayoral, Reynaldo Iracheta-Cortez

    The Rotor Side Converter (RSC) is recognized as a crucial component of the back-to-back power converter utilized in wind turbines, and high failure rates and annual downtime are significantly attributed to it. The challenges encountered are primarily linked to the thermal cycles experienced by power switches due to low-frequency overcurrents. Consequently, the reliability of the RSC is deemed essential for enhancement. This research aims to determine whether low-frequency overcurrents are prompted in the RSC by Extreme Operating Gusts (EOGs) and whether electrical flicker on the direct current bus of the power converter is induced—both of which have been connected to device failures and reduced operational lifespan in existing literature. To address this issue, a novel time-domain EOGs detector is proposed to identify the most intense EOG recorded in La Ventosa, Oaxaca, Mexico, in 2018. Based on this EOG event, two types of small wind turbines were evaluated: one utilizing a grid-connected Doubly Fed Induction Generator (DFIG) and the other employing a grid-isolated Permanent Magnet Synchronous Generator (PMSG). Both systems exhibited significant low-frequency overcurrents and electrical flicker during EOG condition. Furthermore, a full factorial 42 experimental design was implemented on the grid-isolated PMSG-based wind turbine to investigate the influence of EOG amplitude and intensity on the magnitude of RSC overcurrents and the characteristics of flicker-induced voltage oscillations on the direct current bus. The findings reveal that EOG amplitude is the dominant factor driving both overcurrents in the RSC and significant electrical flickers on the direct current bus, ultimately undermining the reliability of the back-to-back power converter.


  • Open Access

    Cómputo reconfigurable en la aceleración de herramientas de Mapeo de ADN

    by Daniel Pacheco Bautista, Francisco Aguilar Acevedo, Yuliana García Amaya, Efraín Dueñas Reyes

    La extracción del código genético a partir del núcleo celular es conocido como secuenciación de ADN y es un tema de investigación actual relevante a nivel mundial dada la importancia que representa. Uno de los pasos de la secuenciación consiste en alinear millones de secuencias cortas a genomas completos de varios cientos de millones de nucleótidos mediante complejos programas informáticos denominados Alineadores o Mapeadores de ADN. No obstante, sus tiempos de ejecución aún son muy largos comparados con la velocidad en que las máquinas NGS producen las secuencias, lo que los convierte en el cuello de botella del proceso general de análisis de ADN. En este artículo se revisa sistemáticamente el uso del cómputo reconfigurable utilizando FPGAs para acelerar herramientas de alineación de lecturas cortas de ADN, identificando los principales algoritmos que se han podido implementar de manera eficiente dentro de cada una de las etapas de tales herramientas, así como los factores de aceleración logrados. Se espera que este artículo sirva de base a futuras investigaciones relacionadas.

  • Open Access

    Aprendizaje flexible a través de materiales interactivos: evaluación del uso de H5P en programación estructurada en estudiantes universitarios

    by Sergio Juárez Vázquez, Abdiel Pérez Méndez, Joel Antonio López Trinidad, Efraín Dueñas Reyes

    Hoy en día, el aprendizaje flexible impulsado por las herramientas tecnológicas se ha vuelto fundamental en la educación superior. El objetivo de este estudio fue analizar el impacto de la implementación de recursos interactivos creados con H5P en la enseñanza de programación estructurada en la Universidad del Istmo. Participaron estudiantes de diversas carreras de ingenierías y matemáticas aplicadas. Se evaluó la aceptación tecnológica, motivación estudiantil e impacto académico de estos recursos. La metodología incluyó una encuesta inicial para identificar necesidades de aprendizaje de los estudiantes, luego se desarrollaron 52 actividades interactivas en una plataforma web. Se utilizó el modelo TAM (Technology Acceptance Model) para medir la aceptación, mientras que para evaluar la motivación se utilizó el cuestionario IMMS, así como el cuestionario SUS (System Usability Scale) para medir la usabilidad. Los resultados mostraron una alta aceptación tecnológica (84/100 en TAM) y motivación (4.45/5 en IMMS), destacando la facilidad de uso y claridad de los contenidos. También se observó una mejora en las calificaciones y una reducción en las tasas de reprobación. Al finalizar el estudio se concluye que H5P es una herramienta efectiva para apoyar el aprendizaje flexible, especialmente en situaciones donde los estudiantes tienen dificultades para comprender conceptos complejos, por eso se recomienda su uso en otros cursos y combinarlo con estrategias pedagógicas como el aula invertida.