Henrique Barcelos Brandão
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Henrique Barcelos Brandão has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Luiz Gonzaga Gandini Junior
Adjunct Professor, Department of Orthodontics, School of Dentistry at Araraquara, UNESP, São Paulo State University, Araraquara, São Paulo, Brazil
6 shared publications - Ary dos Santos Pinto4 shared publications
- José Roberto Alves Moreira4 shared publications
- Alberto Consolaro
Universidade de São Paulo
2 shared publications - Alyssa Schiavon Gandini
São Paulo State University, Brazil
2 shared publications - Alyssa Schiavon Gandini2 shared publications
Latest Publications
- Open Access
- 13 January 2026
- Published by Seven Events
- p. 344-353
MANDIBULAR BONE EROSION ASSOCIATED WITH HYALURONIC ACID FILLER: CBCT CASE REPORT
We report a case of bone erosion in the mental region associated with hyaluronic acid (HA) injection for cosmetic purposes, incidentally identified in a patient undergoing orthodontic treatment with miniscrew-assisted rapid palatal expansion (MARPE). This case offers rare sequential radiographic documentation using cone-beam computed tomography (CBCT) both before and after HA injection, along with intraoperative confirmation of the lesion. These findings provide further support for the hypothesis of HA-induced bone resorption. This report underscores the critical role of imaging in interdisciplinary clinical practice and contributes meaningful evidence regarding the potential adverse effects of facial fillers on underlying osseous structures.
- 13 January 2026
- Published by Seven Events
- p. 344-353
Open AccessMANDIBULAR BONE EROSION ASSOCIATED WITH HYALURONIC ACID FILLER: CBCT CASE REPORT
We report a case of bone erosion in the mental region associated with hyaluronic acid (HA) injection for cosmetic purposes, incidentally identified in a patient undergoing orthodontic treatment with miniscrew-assisted rapid palatal expansion (MARPE). This case offers rare sequential radiographic documentation using cone-beam computed tomography (CBCT) both before and after HA injection, along with intraoperative confirmation of the lesion. These findings provide further support for the hypothesis of HA-induced bone resorption. This report underscores the critical role of imaging in interdisciplinary clinical practice and contributes meaningful evidence regarding the potential adverse effects of facial fillers on underlying osseous structures.
- Open Access
- 9 January 2026
- Published by Seven Events
- p. 238-251
COMPARATIVE ANALYSIS OF MACROSCOPIC VS MICROSCOPIC MEASUREMENT CRITERIA OF INDUCED TOOTH MOVEMENT
This study aims to compare microscopic changes in the periodontal ligament (PDL) thickness with macroscopic tooth displacement in a rat model of orthodontic tooth movement. Seventy rats were divided into two experimental groups (GI and GII, N = 30 each) and a control group (GC, N = 10). GI received continuous orthodontic force with a coil spring appliance (50 cN), while GII received interrupted forces, applied in four-day cycles. The experimental groups were randomly subdivided (N = 10 per subgroup), and euthanized on days 8, 16, and 24 post-appliance installation. The distance between the distal face of the last molar and the mesial face of the first molar was measured to assess macroscopic displacement, calculated by subtracting the measurements of the unmoved side. PDL thickness was measured microscopically, and thickness changes (TC) were calculated by subtracting the mean PDL thickness of the control group. Pearson correlation analysis revealed a strong positive correlation between PDL TC and tooth displacement across all time points (r > 0.83). No significant differences in macroscopic displacement were observed between GI and GII at any time point (p > 0.05), however, the PDL TCs were significantly smaller in GI at all time points (p < 0.02), suggesting faster bone formation in this group. Microscopic changes in PDL TC correlated strongly with macroscopic tooth displacement in our rat model. Bone formation was achieved faster in the continuous force group compared to the interrupted force group while the final tooth displacement was similar.
- 9 January 2026
- Published by Seven Events
- p. 238-251
Open AccessCOMPARATIVE ANALYSIS OF MACROSCOPIC VS MICROSCOPIC MEASUREMENT CRITERIA OF INDUCED TOOTH MOVEMENT
This study aims to compare microscopic changes in the periodontal ligament (PDL) thickness with macroscopic tooth displacement in a rat model of orthodontic tooth movement. Seventy rats were divided into two experimental groups (GI and GII, N = 30 each) and a control group (GC, N = 10). GI received continuous orthodontic force with a coil spring appliance (50 cN), while GII received interrupted forces, applied in four-day cycles. The experimental groups were randomly subdivided (N = 10 per subgroup), and euthanized on days 8, 16, and 24 post-appliance installation. The distance between the distal face of the last molar and the mesial face of the first molar was measured to assess macroscopic displacement, calculated by subtracting the measurements of the unmoved side. PDL thickness was measured microscopically, and thickness changes (TC) were calculated by subtracting the mean PDL thickness of the control group. Pearson correlation analysis revealed a strong positive correlation between PDL TC and tooth displacement across all time points (r > 0.83). No significant differences in macroscopic displacement were observed between GI and GII at any time point (p > 0.05), however, the PDL TCs were significantly smaller in GI at all time points (p < 0.02), suggesting faster bone formation in this group. Microscopic changes in PDL TC correlated strongly with macroscopic tooth displacement in our rat model. Bone formation was achieved faster in the continuous force group compared to the interrupted force group while the final tooth displacement was similar.
- Open Access
- 1 January 2026
- Published by Seven Events in Boletim de Conjuntura (BOCA)
- Vol. 25 (74) , e8105
MANDIBULAR BONE EROSION ASSOCIATED WITH HYALURONIC ACID FILLER: CBCT CASE REPORT
We report a case of bone erosion in the mental region associated with hyaluronic acid (HA) injection for cosmetic purposes, incidentally identified in a patient undergoing orthodontic treatment with miniscrew-assisted rapid palatal expansion (MARPE). This case offers rare sequential radiographic documentation using cone-beam computed tomography (CBCT) both before and after HA injection, along with intraoperative confirmation of the lesion. These findings provide further support for the hypothesis of HA-induced bone resorption. This report underscores the critical role of imaging in interdisciplinary clinical practice and contributes meaningful evidence regarding the potential adverse effects of facial fillers on underlying osseous structures.
- 1 January 2026
- Published by Seven Events in Boletim de Conjuntura (BOCA)
- Vol. 25 (74) , e8105
Open AccessMANDIBULAR BONE EROSION ASSOCIATED WITH HYALURONIC ACID FILLER: CBCT CASE REPORT
We report a case of bone erosion in the mental region associated with hyaluronic acid (HA) injection for cosmetic purposes, incidentally identified in a patient undergoing orthodontic treatment with miniscrew-assisted rapid palatal expansion (MARPE). This case offers rare sequential radiographic documentation using cone-beam computed tomography (CBCT) both before and after HA injection, along with intraoperative confirmation of the lesion. These findings provide further support for the hypothesis of HA-induced bone resorption. This report underscores the critical role of imaging in interdisciplinary clinical practice and contributes meaningful evidence regarding the potential adverse effects of facial fillers on underlying osseous structures.
- Open Access
- 1 January 2026
- Published by Seven Events in ERR01
- Vol. 11 (1) , e11764
THE EFFECT OF MOLAR UPRIGHTING SPRING LENGTH ON FORCE SYSTEMS GENERATED BY NICKEL-TITANIUM SPRINGS
This study evaluated the force system generated by the Memory Titanol Spring (MTS) with different nickel-titanium segment lengths for molar uprighting using an orthodontic force tester (OFT). The springs were activated at 30° in the posterior segment (β) and divided into four groups (G0, G1, G2, G3). The nickel-titanium and steel connection were fixed at 0 mm, 1 mm, 2 mm, and 3 mm from the molar auxiliary tube curvature. Each group had five MTS, with steel measuring 0.017" by 0.022" and nickel-titanium 0.018" by 0.025". Molars showed extrusion in all groups, with mean values of -0.54 N (G0), -0.68 N (G1), -0.66 N (G2), and -0.66 N (G3). The anterior reacting unit showed mandibular premolar intrusion from 0.56 N (G0, G2) to 0.67 N (G3). Uprighting moments (Ty) of the molars indicated distal moments of 17.62 N·mm (G0), 16.47 N·mm (G1), 16.58 N·mm (G2), and 14.76 N·mm (G3). Distal premolar moments were 1.49 N·mm (G0), 2.63 N·mm (G1), 2.44 N·mm (G2), and 2.42 N·mm (G3). Nickel-titanium segment length showed statistical differences. All pre-activations generated molar extrusion and premolar intrusion at low intensity. G0 was most favorable for molar uprighting. All groups showed low-intensity distal moments on the anterior anchorage side, likely sub-optimal.
- 1 January 2026
- Published by Seven Events in ERR01
- Vol. 11 (1) , e11764
Open AccessTHE EFFECT OF MOLAR UPRIGHTING SPRING LENGTH ON FORCE SYSTEMS GENERATED BY NICKEL-TITANIUM SPRINGS
This study evaluated the force system generated by the Memory Titanol Spring (MTS) with different nickel-titanium segment lengths for molar uprighting using an orthodontic force tester (OFT). The springs were activated at 30° in the posterior segment (β) and divided into four groups (G0, G1, G2, G3). The nickel-titanium and steel connection were fixed at 0 mm, 1 mm, 2 mm, and 3 mm from the molar auxiliary tube curvature. Each group had five MTS, with steel measuring 0.017" by 0.022" and nickel-titanium 0.018" by 0.025". Molars showed extrusion in all groups, with mean values of -0.54 N (G0), -0.68 N (G1), -0.66 N (G2), and -0.66 N (G3). The anterior reacting unit showed mandibular premolar intrusion from 0.56 N (G0, G2) to 0.67 N (G3). Uprighting moments (Ty) of the molars indicated distal moments of 17.62 N·mm (G0), 16.47 N·mm (G1), 16.58 N·mm (G2), and 14.76 N·mm (G3). Distal premolar moments were 1.49 N·mm (G0), 2.63 N·mm (G1), 2.44 N·mm (G2), and 2.42 N·mm (G3). Nickel-titanium segment length showed statistical differences. All pre-activations generated molar extrusion and premolar intrusion at low intensity. G0 was most favorable for molar uprighting. All groups showed low-intensity distal moments on the anterior anchorage side, likely sub-optimal.
- Open Access
- 1 January 2026
- Published by Seven Events in LUMEN ET VIRTUS
- Vol. 17 (56) , e11702
PHOTOELASTIC STRESS ANALYSIS OF DIFFERENT MOLAR UPRIGHTING SPRINGS
The aim of this study was to analyze and compare the stress distributions in three molar uprighting techniques: cantilever, uprighting spring and Sander’s Spring, using quantitative and qualitative photoelastic analysis. Seven photoelastic models were made, the second molar was tipped forward 30º and the mandibular right canine and the first and second premolars were the anchor teeth. In each of the photoelastic models, we tested uprighting mechanics randomly. A software Fringes® was used to quantify the model’s shear stress. In the quantitative analysis the nonparametric Kruskal-wallis test demonstrated that only one point of the 18 analyzed, presented statistically significant difference, on point 14 (P=.033). The Post hoc Dunn’s test showed difference between cantilever group and the group Sander's Spring bended 135°. In the qualitative analysis, the highest concentration order of isochromatic fringes was on point 6 of the molar. There was no statistically significant difference in all molar points. On anchor teeth the Sander’s Spring bended 135º presented higher values on the order of fringes. With the results obtained in this research, the clinical decision of which mechanism of verticalization to use will be a personal preference of the orthodontist.
- 1 January 2026
- Published by Seven Events in LUMEN ET VIRTUS
- Vol. 17 (56) , e11702
Open AccessPHOTOELASTIC STRESS ANALYSIS OF DIFFERENT MOLAR UPRIGHTING SPRINGS
The aim of this study was to analyze and compare the stress distributions in three molar uprighting techniques: cantilever, uprighting spring and Sander’s Spring, using quantitative and qualitative photoelastic analysis. Seven photoelastic models were made, the second molar was tipped forward 30º and the mandibular right canine and the first and second premolars were the anchor teeth. In each of the photoelastic models, we tested uprighting mechanics randomly. A software Fringes® was used to quantify the model’s shear stress. In the quantitative analysis the nonparametric Kruskal-wallis test demonstrated that only one point of the 18 analyzed, presented statistically significant difference, on point 14 (P=.033). The Post hoc Dunn’s test showed difference between cantilever group and the group Sander's Spring bended 135°. In the qualitative analysis, the highest concentration order of isochromatic fringes was on point 6 of the molar. There was no statistically significant difference in all molar points. On anchor teeth the Sander’s Spring bended 135º presented higher values on the order of fringes. With the results obtained in this research, the clinical decision of which mechanism of verticalization to use will be a personal preference of the orthodontist.
- Open Access
- 1 January 2026
- Published by Seven Events in LUMEN ET VIRTUS
- Vol. 17 (56) , e11680
COMPARATIVE ANALYSIS OF MACROSCOPIC VS MICROSCOPIC MEASUREMENT CRITERIA OF INDUCED TOOTH MOVEMENT
This study aims to compare microscopic changes in the periodontal ligament (PDL) thickness with macroscopic tooth displacement in a rat model of orthodontic tooth movement. Seventy rats were divided into two experimental groups (GI and GII, N = 30 each) and a control group (GC, N = 10). GI received continuous orthodontic force with a coil spring appliance (50 cN), while GII received interrupted forces, applied in four-day cycles. The experimental groups were randomly subdivided (N = 10 per subgroup), and euthanized on days 8, 16, and 24 post-appliance installation. The distance between the distal face of the last molar and the mesial face of the first molar was measured to assess macroscopic displacement, calculated by subtracting the measurements of the unmoved side. PDL thickness was measured microscopically, and thickness changes (TC) were calculated by subtracting the mean PDL thickness of the control group. Pearson correlation analysis revealed a strong positive correlation between PDL TC and tooth displacement across all time points (r > 0.83). No significant differences in macroscopic displacement were observed between GI and GII at any time point (p > 0.05), however, the PDL TCs were significantly smaller in GI at all time points (p < 0.02), suggesting faster bone formation in this group. Microscopic changes in PDL TC correlated strongly with macroscopic tooth displacement in our rat model. Bone formation was achieved faster in the continuous force group compared to the interrupted force group while the final tooth displacement was similar.
- 1 January 2026
- Published by Seven Events in LUMEN ET VIRTUS
- Vol. 17 (56) , e11680
Open AccessCOMPARATIVE ANALYSIS OF MACROSCOPIC VS MICROSCOPIC MEASUREMENT CRITERIA OF INDUCED TOOTH MOVEMENT
This study aims to compare microscopic changes in the periodontal ligament (PDL) thickness with macroscopic tooth displacement in a rat model of orthodontic tooth movement. Seventy rats were divided into two experimental groups (GI and GII, N = 30 each) and a control group (GC, N = 10). GI received continuous orthodontic force with a coil spring appliance (50 cN), while GII received interrupted forces, applied in four-day cycles. The experimental groups were randomly subdivided (N = 10 per subgroup), and euthanized on days 8, 16, and 24 post-appliance installation. The distance between the distal face of the last molar and the mesial face of the first molar was measured to assess macroscopic displacement, calculated by subtracting the measurements of the unmoved side. PDL thickness was measured microscopically, and thickness changes (TC) were calculated by subtracting the mean PDL thickness of the control group. Pearson correlation analysis revealed a strong positive correlation between PDL TC and tooth displacement across all time points (r > 0.83). No significant differences in macroscopic displacement were observed between GI and GII at any time point (p > 0.05), however, the PDL TCs were significantly smaller in GI at all time points (p < 0.02), suggesting faster bone formation in this group. Microscopic changes in PDL TC correlated strongly with macroscopic tooth displacement in our rat model. Bone formation was achieved faster in the continuous force group compared to the interrupted force group while the final tooth displacement was similar.
- Open Access
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Revista de Odontologia da UNESP
- Vol. 54, e20250019
Three-dimensional analysis of dental arch changes after first premolar extractions and en masse or two-step retraction in Class I biprotrusions
Introduction The extraction of permanent teeth, particularly premolars, has been a subject of debate in orthodontics centered on the space requirements for resolving malocclusion and its potential impact on the development of dental arches.
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Revista de Odontologia da UNESP
- Vol. 54, e20250019
Open AccessThree-dimensional analysis of dental arch changes after first premolar extractions and en masse or two-step retraction in Class I biprotrusions
Introduction The extraction of permanent teeth, particularly premolars, has been a subject of debate in orthodontics centered on the space requirements for resolving malocclusion and its potential impact on the development of dental arches.
- Open Access
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Dental Press Journal of Orthodontics
- Vol. 29 (5) , e242430
Evaluation of force systems generated by Memory Titanol® springs with different preactivation bends
Objective: This study evaluated the force system generated by the Memory Titanol® spring (MTS) with different preactivation bends using an orthodontic force tester (OFT). Methods: Three preactivations were tested using a 0.017 × 0.022-in stainless steel (SS) wire and a 0.018 × 0.025-in NiTi segment, with an activation of 30º in the posterior segment (β), with 0º (Group 1 [G1]), 45º (Group 2 [G2]), and 60º (Group 3 [G3]) in the anterior segment (α). Results: The molars showed extrusion values of −1.33 N for G1 and −0.78 N for G2, and an intrusion value of 0.33 N for G3. The force in the premolars was intrusive with a variation of 1.34 N for G1 and 0.77 N for G2; and extrusive with a variation of −0.31 N for G3. Regarding the upright moment (Ty) of the molar, a distal moment was observed with values of 53.45 N.mm for G1 and 19.87 N.mm for G2, while G3 presented a mesial moment of −6.23 N.mm. G1, G2, and G3 all exhibited distal premolar moments (Ty) of 3.58, 2.45, and 0.68 N.mm, respectively. Conclusions: The tested preactivations exerted an extrusive force in G1 and G2 and an intrusive force in G3 during molar vertical movement. The premolar region in G1 and G2 showed intrusive force and distal moment.
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Dental Press Journal of Orthodontics
- Vol. 29 (5) , e242430
Open AccessEvaluation of force systems generated by Memory Titanol® springs with different preactivation bends
Objective: This study evaluated the force system generated by the Memory Titanol® spring (MTS) with different preactivation bends using an orthodontic force tester (OFT). Methods: Three preactivations were tested using a 0.017 × 0.022-in stainless steel (SS) wire and a 0.018 × 0.025-in NiTi segment, with an activation of 30º in the posterior segment (β), with 0º (Group 1 [G1]), 45º (Group 2 [G2]), and 60º (Group 3 [G3]) in the anterior segment (α). Results: The molars showed extrusion values of −1.33 N for G1 and −0.78 N for G2, and an intrusion value of 0.33 N for G3. The force in the premolars was intrusive with a variation of 1.34 N for G1 and 0.77 N for G2; and extrusive with a variation of −0.31 N for G3. Regarding the upright moment (Ty) of the molar, a distal moment was observed with values of 53.45 N.mm for G1 and 19.87 N.mm for G2, while G3 presented a mesial moment of −6.23 N.mm. G1, G2, and G3 all exhibited distal premolar moments (Ty) of 3.58, 2.45, and 0.68 N.mm, respectively. Conclusions: The tested preactivations exerted an extrusive force in G1 and G2 and an intrusive force in G3 during molar vertical movement. The premolar region in G1 and G2 showed intrusive force and distal moment.