SMSvetozar Matanov

Svetozar Matanov

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Svetozar Matanov has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Subacute Stent Deformities as an Underlying Reason for Vessel Stenosis after Flow Diversion with the p64 Stent: Review and Discussion of Biologic Mechanisms and Consequences

    by G. Vladev, A. Sirakov, S. Matanov, K. Sirakova, K. Ninov, S. Sirakov

    Flow-diverter stents are a potent and efficient tool in the instrumentarium of neurointerventional radiologists for the treatment of intracranial aneurysms. With their implementation, some adverse effects and complications such as hemorrhagic and ischemic ones, have been seen as a potential downfall of the method. In-stent stenosis is one such complication, which until now has not received enormous attention due to its seemingly benign characteristic. In our study we propose a different point of view on this matter and aim to establish a potential mechanism for its development: a subacute postprocedural stent deformation, due to segmental vessel constriction as a reaction to the implant. We enrolled 48 patients between the ages of 31 and 71 (8 men) with aneurysms on the distal portions of the ICA, all of whom were treated with the p64 flow-diverter stent, to assess the incidence of this phenomenon, as well as establish a correlation between it and subsequent clinical symptoms. A protocol for short-term follow-up, consisting only of a high-dose fluoroscopy image of the implant (conducted on the 14th postprocedural day) was implemented to assess the state of the implant before endothelization was to be expected. Stent deformities were seen in 58% of cases. One patient with an observed stent deformity presented with several episodes of acute contralateral 1-sided weakness of the limbs. Seventy-one percent of those patients presented with a mild/moderate unilateral headache postprocedurally. A correlation between the deformity and a subsequent narrowing of the parent vessel diameter was established on follow-ups. Notable in-stent stenosis was reported in 35% of all cases. Cases with subacute stent deformities are presented in a nonnegligible percent of flow-diversion therapies with the p64 stent. A statistically significant association between the observed deformation and subsequent in-stent stenosis was observed on follow-up.


  • Open Access

    The significance of stent sizing for parent vessel stenosis after flow diversion of MCA bifurcation aneurysms

    by Svetozar Matanov, Georgi Vladev, Alexander Sirakov, Kristian Ninov, Marin Penkov, Hristo Tsonev, Kristina Sirakova, Vasil Karakostov, Stanimir Sirakov

    Background: Wide-necked bifurcation aneurysms (WNBA) of the middle cerebral artery (MCA) present significant therapeutic challenges. Flow-diverter stents have been increasingly adopted for their management, though they may give rise to adverse outcomes such as in-stent stenosis (ISS). This study explores the association between stent oversizing and the incidence of ISS following flow-diverter stent placement in MCA bifurcation aneurysms. Methods: A retrospective study included 34 patients who underwent flow-diverter stent placement for MCA bifurcation aneurysms between 2020 and 2023. Data on patient demographics, aneurysm morphology, and stent sizing were collected. ISS was evaluated through follow-up imaging at 6-month post-procedure. Stent oversizing was determined by calculating the difference between the stent diameter and the proximal and distal parent vessel diameters. Statistical analyses included Pearson correlation and chi-square tests, with significance established at p < 0.05. Results: The studied group had a mean age of 57.8 years, with 81.6% female patients. The average aneurysm neck size was 3.6 mm, with a mean dome-to-neck ratio of 1.6. ISS was detected in 64.7% of cases proximally and 88.2% distally. A statistically significant negative correlation ( r = −0.496, p = 0.003) was observed between stent oversizing and ISS, indicating that increased stent oversizing was associated with a higher incidence of ISS, particularly in the distal vessel segments. Conclusion: The findings indicate that stent oversizing is significantly associated with the development of ISS in MCA bifurcation aneurysms treated with flow-diverter stents. Careful consideration of stent sizing, particularly minimizing oversizing in distal segments, may mitigate the risk of ISS and improve clinical outcomes. These results underscore the importance of meticulous stent selection and procedural planning in neurointerventional practice.