Amparo Averbuj
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Amparo Averbuj has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Heidi Rataj
UC San Diego, La Jolla, California, USA
2 shared publications - Manas Satish Bedmutha
UC San Diego, La Jolla, California, USA
2 shared publications - Nadir Weibel
UC San Diego, La Jolla, California, USA
2 shared publications - Nicole May
UC San Diego Health, San Diego, California, USA
2 shared publications - Poorva Satish Bedmutha
Department of Electrical and Computer Engineering University of California San Diego California USA
2 shared publications - Sahithi Karumudi
UC San Diego, La Jolla, California, USA
2 shared publications
Latest Publications
- Open Access
- 4 July 2026
- Published by Association for Computing Machinery (ACM)
- p. 1-5
Designing for College Mental Health: We Have Resources; We Lack the Reach
- 4 July 2026
- Published by Association for Computing Machinery (ACM)
- p. 1-5
Open AccessDesigning for College Mental Health: We Have Resources; We Lack the Reach
- Open Access
- 13 April 2026
- Published by Association for Computing Machinery (ACM)
- p. 1-7
The Campus Mental Health Problem Isn't Capacity - It's Access!
- 13 April 2026
- Published by Association for Computing Machinery (ACM)
- p. 1-7
Open AccessThe Campus Mental Health Problem Isn't Capacity - It's Access!
- Open Access
- 5 October 2024
- Published by Association for Computing Machinery (ACM)
- p. 220-224
VibroBP: An Oscillometric Smartphone Blood Pressure App
This interactivity features a smartphone-based method for measuring blood pressure (BP) using the oscillometric method. To measure BP, it is necessary to measure (1) the pressure applied to the artery and (2) the local blood volume change. This is accomplished by performing an oscillometric measurement at the finger's digital artery, whereby a user presses down on the phone's camera with steadily increasing force. The camera is used to capture the blood volume change using photoplethysmography. We devised a novel method for measuring the force applied by the finger without the use of specialized smartphone hardware with a technique called Vibrometric Force Estimation (VFE). The fundamental concept of VFE relies on a phenomenon where a vibrating object is dampened when an external force is applied on it. This phenomenon can be recreated using the phone's own vibration motor, where the resulting damped vibration is measured using the smartphone's Inertial Measurement Unit (IMU). A cross device reliability study with three smartphones of different manufacturers, shape, and prices results in similar force estimation performance across all smartphone models. In an N=24 validation study of the BP measurement, the smartphone technique achieves a MAE of 8.4 mmHg and 8.5 mmHg of systolic and diastolic BP, respectively, compared to an FDA approved BP cuff. The mean error (bias) and standard deviation are 0.44±10.2 mmHg and 0.03±10.5mmHg for systolic and diastolic, respectively. The vision for this technology is not necessarily to replace existing BP monitoring solutions, but rather to introduce a downloadable smartphone software application that could serve as a low-barrier hypertension screening measurement fit for widespread adoption.
- 5 October 2024
- Published by Association for Computing Machinery (ACM)
- p. 220-224
Open AccessVibroBP: An Oscillometric Smartphone Blood Pressure App
This interactivity features a smartphone-based method for measuring blood pressure (BP) using the oscillometric method. To measure BP, it is necessary to measure (1) the pressure applied to the artery and (2) the local blood volume change. This is accomplished by performing an oscillometric measurement at the finger's digital artery, whereby a user presses down on the phone's camera with steadily increasing force. The camera is used to capture the blood volume change using photoplethysmography. We devised a novel method for measuring the force applied by the finger without the use of specialized smartphone hardware with a technique called Vibrometric Force Estimation (VFE). The fundamental concept of VFE relies on a phenomenon where a vibrating object is dampened when an external force is applied on it. This phenomenon can be recreated using the phone's own vibration motor, where the resulting damped vibration is measured using the smartphone's Inertial Measurement Unit (IMU). A cross device reliability study with three smartphones of different manufacturers, shape, and prices results in similar force estimation performance across all smartphone models. In an N=24 validation study of the BP measurement, the smartphone technique achieves a MAE of 8.4 mmHg and 8.5 mmHg of systolic and diastolic BP, respectively, compared to an FDA approved BP cuff. The mean error (bias) and standard deviation are 0.44±10.2 mmHg and 0.03±10.5mmHg for systolic and diastolic, respectively. The vision for this technology is not necessarily to replace existing BP monitoring solutions, but rather to introduce a downloadable smartphone software application that could serve as a low-barrier hypertension screening measurement fit for widespread adoption.