Nguyen Tat Thang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Nguyen Tat Thang has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Koichi Mashiko
Fujikura Ltd., Tokyo, Japan
2 shared publicationsMasataka Mochizuki
Fujikura Ltd., Tokyo, Japan
2 shared publications- Tien Nguyen
Shibaura Institute of Technology Graduate School, 307 Fukasaku, Minumaku, Saitama city, Saitama, Japan National Research Institute of Mechanical Engineering, 4 Pham Van Dong, Cau Giay, Hanoi, Vietnam
2 shared publications Vijit Wuttijumnong
Fujikura Ltd., Tokyo, Japan
2 shared publications- Yuji Saito
Tohoku University
2 shared publications - Chu Manh Hung
School of Materials Science and Engineering, Hanoi University of Science and Technology, No 1 Dai Co Viet, Hanoi, Vietnam
1 shared publication
Latest Publications
- Open Access
- 15 March 2025
- Published by Elsevier in International Journal of Mechanical Sciences
- Vol. 291-292
Discrete element modelling of electro-mechanical behaviour in modified cementitious materials
- 15 March 2025
- Published by Elsevier in International Journal of Mechanical Sciences
- Vol. 291-292
Open AccessDiscrete element modelling of electro-mechanical behaviour in modified cementitious materials
- Open Access
- 16 September 2024
- Published by Elsevier in Computer Methods in Applied Mechanics and Engineering
- Vol. 432
Development of free-field and compliant base SPH boundary conditions for large deformation seismic response analysis of geomechanics problems
- 16 September 2024
- Published by Elsevier in Computer Methods in Applied Mechanics and Engineering
- Vol. 432
Open AccessDevelopment of free-field and compliant base SPH boundary conditions for large deformation seismic response analysis of geomechanics problems
- Open Access
- 31 May 2022
- Published by Hanoi University of Civil Engineering (HUCE) in Journal of Science and Technology in Civil Engineering
- Vol. 16 (3) , 18-28
Navier solution for static and free vibration analysis of sandwich plate with auxetic honeycomb core resting on pasternak elastic foundation
This study investigates the bending behaviour and free vibration response of a rectangular sandwich plate with auxetic honeycomb core and functionally graded material (FGM) face sheets. Governing equations are established from Hamilton’s principle in the framework of the first-order deformation theory (FSDT). The Navier solution has been utilized to determine the deflection and the natural frequency of the simply supported sandwich plate. The reliability and accuracy of the proposed model have been validated via verification studies. The numerical investigations are conducted to investigate the influence of geometric parameters of auxetic material, volume fraction index of FGM, the thickness ratio of layers, and elastic foundation stiffness on deflection and fundamental frequency of the FG-Auxetic sandwich plate.
- 31 May 2022
- Published by Hanoi University of Civil Engineering (HUCE) in Journal of Science and Technology in Civil Engineering
- Vol. 16 (3) , 18-28
Open AccessNavier solution for static and free vibration analysis of sandwich plate with auxetic honeycomb core resting on pasternak elastic foundation
This study investigates the bending behaviour and free vibration response of a rectangular sandwich plate with auxetic honeycomb core and functionally graded material (FGM) face sheets. Governing equations are established from Hamilton’s principle in the framework of the first-order deformation theory (FSDT). The Navier solution has been utilized to determine the deflection and the natural frequency of the simply supported sandwich plate. The reliability and accuracy of the proposed model have been validated via verification studies. The numerical investigations are conducted to investigate the influence of geometric parameters of auxetic material, volume fraction index of FGM, the thickness ratio of layers, and elastic foundation stiffness on deflection and fundamental frequency of the FG-Auxetic sandwich plate.
- 1 April 2021
- Published by American Scientific Publishers in Journal of Nanoscience and Nanotechnology
- Vol. 21 (4) , 2626-2632
Fabrication of p-Type Co3O4 Nanofiber Sensors for Ultra-Low H2S Gas Detection at Low Temperature
In the current work, we report the on-chip fabrication of a low-temperature H2S sensor based on p-type Co3O4 nanofibers (NFs) using the electrospinning method. The FESEM images show the typical spider-net like morphologies of synthesized Co3O4 NFs with an average diameter of 90 nm formed on the comb-like electrodes. The EDX data indicate the presence of Co and O elements in the NFs. The XRD analysis results confirm the formation of single-phase cubic spinel nanocrystalline structures (Fd3 m) for the synthesized Co3O4 NFs. The Raman results are in agreement with the XRD data through the presence of five typical vibration modes of the nanocrystalline Co3O4. The gas sensing properties of the fabricated Co3O4 NF sensors are tested to 1 ppm H2S within a temperature range of 150 °C to 450 °C. The results indicate a highest sensor response to 1 ppm H2S with the gas response of aproximately 2.1 times and the gas response/recovery times of 75 s/258 s at a low temperature of 250 °C. The fabricated sensor also demonstrates good selectivity and a low detection limit of 18 ppb. The overall results suggest a simple and effective fabrication process for the p-type Co3O4 NF sensor for practical applications in detecting H2S gas at low temperature.
- 1 April 2021
- Published by American Scientific Publishers in Journal of Nanoscience and Nanotechnology
- Vol. 21 (4) , 2626-2632
Fabrication of p-Type Co3O4 Nanofiber Sensors for Ultra-Low H2S Gas Detection at Low Temperature
In the current work, we report the on-chip fabrication of a low-temperature H2S sensor based on p-type Co3O4 nanofibers (NFs) using the electrospinning method. The FESEM images show the typical spider-net like morphologies of synthesized Co3O4 NFs with an average diameter of 90 nm formed on the comb-like electrodes. The EDX data indicate the presence of Co and O elements in the NFs. The XRD analysis results confirm the formation of single-phase cubic spinel nanocrystalline structures (Fd3 m) for the synthesized Co3O4 NFs. The Raman results are in agreement with the XRD data through the presence of five typical vibration modes of the nanocrystalline Co3O4. The gas sensing properties of the fabricated Co3O4 NF sensors are tested to 1 ppm H2S within a temperature range of 150 °C to 450 °C. The results indicate a highest sensor response to 1 ppm H2S with the gas response of aproximately 2.1 times and the gas response/recovery times of 75 s/258 s at a low temperature of 250 °C. The fabricated sensor also demonstrates good selectivity and a low detection limit of 18 ppb. The overall results suggest a simple and effective fabrication process for the p-type Co3O4 NF sensor for practical applications in detecting H2S gas at low temperature.
- 1 January 2011
- Published by ASME International
- p. 653-661
Contribution of Heat Pipe to the Energy Conservation of Data Center and Cloud Computers
With the current increase of the electrical power consumption of the data center imposed a great concern in the world about sustainable energy and global warming and it is therefore required innovative ideas to conserve the energy consumption. Authors propose the use of heat pipe which is a best known passive heat transfer device that is well suitable apply for energy saving system in the current data center cooling system. In this paper, a design and economics of the novel type of thermal control system for data center cooling using heat pipe based cold energy storage system has been proposed and discussed. The cold water storage system is explained and sized for data center with heat output capacity of 8,800 kW. Basically, the cold energy storage will help to downsize the chiller and decrease its runtime that will save electricity related cost and decrease green house gases emissions resulting from the electricity generation. The proposed cold energy storage system can be retrofit or connected in the existing data center facilities without major design changes. Water based cold energy storage system provides more compact size with short term storage (hours to days) and is potential for both small to large size data center with yearly average temperature below the cold storage water temperature (∼ 25 °C). The cold water storage system is sized on the basis of metrological conditions in North America, USA. As an outcome of the thermal and cost analysis, an optimum size of cold energy storage system should be designed to handle 60% of the yearly data center load. The proposed system can be easily integrated into the existing conventional systems without any significant infrastructure changes. Preliminary results obtained from the experimental system design to test the ice formation potential of the heat pipe based cold energy storage system has been shown good result and validated the proposed concept.
- 1 January 2011
- Published by ASME International
- p. 653-661
Contribution of Heat Pipe to the Energy Conservation of Data Center and Cloud Computers
With the current increase of the electrical power consumption of the data center imposed a great concern in the world about sustainable energy and global warming and it is therefore required innovative ideas to conserve the energy consumption. Authors propose the use of heat pipe which is a best known passive heat transfer device that is well suitable apply for energy saving system in the current data center cooling system. In this paper, a design and economics of the novel type of thermal control system for data center cooling using heat pipe based cold energy storage system has been proposed and discussed. The cold water storage system is explained and sized for data center with heat output capacity of 8,800 kW. Basically, the cold energy storage will help to downsize the chiller and decrease its runtime that will save electricity related cost and decrease green house gases emissions resulting from the electricity generation. The proposed cold energy storage system can be retrofit or connected in the existing data center facilities without major design changes. Water based cold energy storage system provides more compact size with short term storage (hours to days) and is potential for both small to large size data center with yearly average temperature below the cold storage water temperature (∼ 25 °C). The cold water storage system is sized on the basis of metrological conditions in North America, USA. As an outcome of the thermal and cost analysis, an optimum size of cold energy storage system should be designed to handle 60% of the yearly data center load. The proposed system can be easily integrated into the existing conventional systems without any significant infrastructure changes. Preliminary results obtained from the experimental system design to test the ice formation potential of the heat pipe based cold energy storage system has been shown good result and validated the proposed concept.
- 1 January 2009
- Published by ASME International
- p. 389-394
Application of Micro-Channel Fin for Cold Plate of Liquid Cooling System and Vapor Chamber
Recently energy saving is most important concept for all electric products and production. Especially, in Data-Center cooling system, power consumption of current air cooling system is increasing. For not only improving thermal performance but also reducing electric power consumption of this system, liquid cooling system has been developed. This paper reports the development of cold plate technology and vapor chamber application by using micro-channel fin. In case of cold plate application, micro-channel fin technology is good for compact space design, high thermal performance, and easy for design and simulation. Another application is the evaporating surface for vapor chamber. The well-known devices for effective heat transfer or heat spreading with the lowest thermal resistance are heat pipes and vapor chamber, which are two-phase heat transfer devices with excellent heat spreading and heat transfer characteristics. Normally, vapor chamber is composed of sintered power wick. Vapor chamber container is mechanically supported by stamped pedestal or wick column or solid column, but the mechanical strength is not enough strong. So far, the application is limited in the area of low strength assembly. Sometime the mechanical supporting frame is design for preventing deformation. In this paper, the testing result of sample is described that thermal resistance between the heat source and the ambient can be improved approximately 0.1°C/W by using the micro-channel vapor chamber. Additionally, authors presented case designs using vapor chamber for cooling computer processors, and proposed ideas of using micro-channel vapor chamber for heat spreading to replace the traditional metal plate heat spreader.
- 1 January 2009
- Published by ASME International
- p. 389-394
Application of Micro-Channel Fin for Cold Plate of Liquid Cooling System and Vapor Chamber
Recently energy saving is most important concept for all electric products and production. Especially, in Data-Center cooling system, power consumption of current air cooling system is increasing. For not only improving thermal performance but also reducing electric power consumption of this system, liquid cooling system has been developed. This paper reports the development of cold plate technology and vapor chamber application by using micro-channel fin. In case of cold plate application, micro-channel fin technology is good for compact space design, high thermal performance, and easy for design and simulation. Another application is the evaporating surface for vapor chamber. The well-known devices for effective heat transfer or heat spreading with the lowest thermal resistance are heat pipes and vapor chamber, which are two-phase heat transfer devices with excellent heat spreading and heat transfer characteristics. Normally, vapor chamber is composed of sintered power wick. Vapor chamber container is mechanically supported by stamped pedestal or wick column or solid column, but the mechanical strength is not enough strong. So far, the application is limited in the area of low strength assembly. Sometime the mechanical supporting frame is design for preventing deformation. In this paper, the testing result of sample is described that thermal resistance between the heat source and the ambient can be improved approximately 0.1°C/W by using the micro-channel vapor chamber. Additionally, authors presented case designs using vapor chamber for cooling computer processors, and proposed ideas of using micro-channel vapor chamber for heat spreading to replace the traditional metal plate heat spreader.