Jeremy Kimmel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jeremy Kimmel has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Kathleen Campbell Garwood
Department of Decision and System Sciences, Saint Joseph’s University, Philadelphia, PA 19131, USA
4 shared publications - Kyla Frenia
Department of Bioengineering, Swanson School of Engineering, University of Pittsburgh, Pittsburgh, PA 15260, USA
4 shared publications - Leanne T. Labriola
Pittsburgh Research Institute, Sewickley, PA 15143, USA
4 shared publications - David L. Bartlett
Allegheny Health Network Cancer Institute, Pittsburgh, PA 15212, USA
2 shared publications - Dipanjan Pan
Pennsylvania State University
2 shared publications - James Xiao
Retina Department, Sewickley Eye Group, Sewickley, PA 15143, USA
2 shared publications
Latest Publications
- Open Access
- 6 February 2025
- Published by MDPI AG in Biomedicines
- Vol. 13 (2) , 386
Precision in Tear Fluid Biomarker Discovery: Quantitative Proteomic Profiling of Small-Volume, Individual Samples Using Capillary Tube Collection
Background: Tear fluid, rich in proteins, is a promising source of novel biomarkers for ocular and systemic health. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is the primary method for biomarker discovery. Still, factors such as limited sample volume, extracellular protein contamination, and reflex tearing can significantly impact results. Glass microcapillary tubes minimize these issues. Schirmer strips remain the most common collection method due to existing LC-MS/MS protocol optimization. Methods: In this study, we evaluated multiple digestion protocols for the shotgun quantitative LC-MS/MS analysis of small-volume tear fluid samples collected using glass capillary tubes. Protocol optimization was performed using pooled samples and then compared with the analysis of individual samples. Results: Using the optimized protocol, one μL samples were processed using a timsTOF Pro 2 mass spectrometer (Bruker) coupled online with an Evosep One liquid chromatography system (Evosep), leading to the identification of an average of 361 ± 63 proteins in pooled samples and 525 ± 123 proteins in individual small-volume tear fluid samples. Conclusions: This protocol highlights the practicality of using glass capillary tubes for comprehensive LC-MS/MS-based tear proteomics analysis, paving the way for detailed proteomics characterization of individual tear fluid samples rather than pooled samples. By shifting from pooled to individual samples, this approach greatly accelerates tear biomarker discovery, advancing precision and personalized medicine.
- 6 February 2025
- Published by MDPI AG in Biomedicines
- Vol. 13 (2) , 386
Open AccessPrecision in Tear Fluid Biomarker Discovery: Quantitative Proteomic Profiling of Small-Volume, Individual Samples Using Capillary Tube Collection
Background: Tear fluid, rich in proteins, is a promising source of novel biomarkers for ocular and systemic health. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is the primary method for biomarker discovery. Still, factors such as limited sample volume, extracellular protein contamination, and reflex tearing can significantly impact results. Glass microcapillary tubes minimize these issues. Schirmer strips remain the most common collection method due to existing LC-MS/MS protocol optimization. Methods: In this study, we evaluated multiple digestion protocols for the shotgun quantitative LC-MS/MS analysis of small-volume tear fluid samples collected using glass capillary tubes. Protocol optimization was performed using pooled samples and then compared with the analysis of individual samples. Results: Using the optimized protocol, one μL samples were processed using a timsTOF Pro 2 mass spectrometer (Bruker) coupled online with an Evosep One liquid chromatography system (Evosep), leading to the identification of an average of 361 ± 63 proteins in pooled samples and 525 ± 123 proteins in individual small-volume tear fluid samples. Conclusions: This protocol highlights the practicality of using glass capillary tubes for comprehensive LC-MS/MS-based tear proteomics analysis, paving the way for detailed proteomics characterization of individual tear fluid samples rather than pooled samples. By shifting from pooled to individual samples, this approach greatly accelerates tear biomarker discovery, advancing precision and personalized medicine.
- Open Access
- 26 December 2024
- Published by MDPI AG in Preprints.org
Precision in Tear Fluid Biomarker Discovery: Quantitative Proteomic Profiling of Small-Volume, Individual Samples Using Capillary Tube Collection
Background/Objectives: Tear fluid, a complex biofluid that contains thousands of proteins and can be collected non-invasively, has emerged as a promising source of biomarkers for ocular and systemic health. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is currently the primary method for discovering novel biomarkers in tear fluid. However, the method of tear collection can significantly impact LC-MS/MS analysis outcomes. Tear fluid is commonly collected using either Schirmer strips or capillary tubes. While capillary tubes offer distinct advantages, such as reduced extracellular contamination and reflex tearing, most LC-MS/MS protocol development has focused on optimizing protocols for Schirmer strips. This study addresses this gap by evaluating digestion protocols for tear fluid collected with capillary tubes, focusing on biomarker discovery using small-volume samples. In this study, we evaluated multiple digestion protocols for the shotgun quantitative LC-MS/MS analysis of small-volume tear fluid samples collected using glass capillary tubes. Protocol optimization was performed using pooled samples and then compared with the analysis of individual samples. With the optimized protocol, we identified an average of 368 ± 87 proteins in pooled samples and 502 ± 127 proteins in individual small-volume tear fluid samples, using less than 1µL of total fluid volume. This protocol highlights the practicality of using glass capillary tubes for comprehensive LC-MS/MS-based tear proteomics analysis, paving the way for detailed proteomics characterization of individual tear fluid samples rather than pooled samples. By shifting from pooled to individual samples, this approach greatly accelerates tear biomarker discovery, advancing precision and personalized medicine.
- 26 December 2024
- Published by MDPI AG in Preprints.org
Open AccessPrecision in Tear Fluid Biomarker Discovery: Quantitative Proteomic Profiling of Small-Volume, Individual Samples Using Capillary Tube Collection
Background/Objectives: Tear fluid, a complex biofluid that contains thousands of proteins and can be collected non-invasively, has emerged as a promising source of biomarkers for ocular and systemic health. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is currently the primary method for discovering novel biomarkers in tear fluid. However, the method of tear collection can significantly impact LC-MS/MS analysis outcomes. Tear fluid is commonly collected using either Schirmer strips or capillary tubes. While capillary tubes offer distinct advantages, such as reduced extracellular contamination and reflex tearing, most LC-MS/MS protocol development has focused on optimizing protocols for Schirmer strips. This study addresses this gap by evaluating digestion protocols for tear fluid collected with capillary tubes, focusing on biomarker discovery using small-volume samples. In this study, we evaluated multiple digestion protocols for the shotgun quantitative LC-MS/MS analysis of small-volume tear fluid samples collected using glass capillary tubes. Protocol optimization was performed using pooled samples and then compared with the analysis of individual samples. With the optimized protocol, we identified an average of 368 ± 87 proteins in pooled samples and 502 ± 127 proteins in individual small-volume tear fluid samples, using less than 1µL of total fluid volume. This protocol highlights the practicality of using glass capillary tubes for comprehensive LC-MS/MS-based tear proteomics analysis, paving the way for detailed proteomics characterization of individual tear fluid samples rather than pooled samples. By shifting from pooled to individual samples, this approach greatly accelerates tear biomarker discovery, advancing precision and personalized medicine.
- Open Access
- 14 November 2024
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 25 (22) , 12239
High-Throughput Tear Proteomics via In-Capillary Digestion for Biomarker Discovery
Tear fluid has emerged as a valuable resource for biomarker discovery; however, the limited sample volume, the dynamic composition, and the variability introduced by collection methods all present significant challenges to the analysis and interpretation of the results. A majority of tear proteomic studies have utilized Schirmer strips for tear fluid collection; however, microcapillary collection can provide a superior collection method for proteomic studies when analysis procedures are optimized. We developed a novel, high-throughput in-capillary trypsin digestion workflow that requires as little as 0.5 μL of tear fluid for bottom–up shotgun proteomics. The use of a single microcentrifuge tube for both tear collection and sample processing simplifies sample handling and minimizes both the sample loss and experimental errors associated with sample transfers. This streamlined approach also reduces sample processing time to under 2 h before overnight trypsin digestion, compared to the 5–8 h required by the other methods. Our method uses liquid chromatography–tandem mass spectrometry (LC–MS/MS) to identify more proteins with greater efficiency than the existing techniques. With this workflow, we identified 500–800 proteins per 0.5 μL sample without peptide fractionation, allowing for at least three technical replicates. The results showed a four-fold increase in the number of proteins identified in the samples. This approach validates the use of microcapillary tear collection, and the innovative processing technique significantly increases the throughput of tear proteomics for biomarker discovery.
- 14 November 2024
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 25 (22) , 12239
Open AccessHigh-Throughput Tear Proteomics via In-Capillary Digestion for Biomarker Discovery
Tear fluid has emerged as a valuable resource for biomarker discovery; however, the limited sample volume, the dynamic composition, and the variability introduced by collection methods all present significant challenges to the analysis and interpretation of the results. A majority of tear proteomic studies have utilized Schirmer strips for tear fluid collection; however, microcapillary collection can provide a superior collection method for proteomic studies when analysis procedures are optimized. We developed a novel, high-throughput in-capillary trypsin digestion workflow that requires as little as 0.5 μL of tear fluid for bottom–up shotgun proteomics. The use of a single microcentrifuge tube for both tear collection and sample processing simplifies sample handling and minimizes both the sample loss and experimental errors associated with sample transfers. This streamlined approach also reduces sample processing time to under 2 h before overnight trypsin digestion, compared to the 5–8 h required by the other methods. Our method uses liquid chromatography–tandem mass spectrometry (LC–MS/MS) to identify more proteins with greater efficiency than the existing techniques. With this workflow, we identified 500–800 proteins per 0.5 μL sample without peptide fractionation, allowing for at least three technical replicates. The results showed a four-fold increase in the number of proteins identified in the samples. This approach validates the use of microcapillary tear collection, and the innovative processing technique significantly increases the throughput of tear proteomics for biomarker discovery.
- Open Access
- 8 October 2024
- Published by MDPI AG in Preprints.org
Rapid Tear Proteomics via In-Capillary Digestion for Biomarker Discovery
Tear fluid is emerging as a valuable resource for biomarker discovery, but its low sample volume and dynamic composition pose significant challenges for analytical testing. Most tear proteomics studies have focused on samples collected with Schirmer strips, while capillary tube collection has received less attention. To address these challenges, we developed a novel in-capillary trypsin digestion workflow that requires as little as 0.5 μL of tear fluid for bottom-up shotgun proteomics. This method uses liquid chromatography-tandem mass spectrometry (LC-MS/MS) to identify a higher number of proteins with enhanced efficiency compared to previously reported methods, which typically required 5-10 μL of pooled tear fluid. Using the same microcentrifuge tube for both tear collection and sample processing, this streamlined workflow simplifies sample handling and minimizes both sample loss and experimental errors associated with sample transfer. This method also efficiently reduced sample processing time to under 2 hours prior to overnight trypsin digestion, compared to the 5-8 hours required by other methods. With this workflow, we identified 500-800 proteins per 0.5 μL sample without the need for fractionation, allowing for at least three technical replicates. This optimized workflow greatly enhances the efficiency of tear proteomics for biomarker discovery.
- 8 October 2024
- Published by MDPI AG in Preprints.org
Open AccessRapid Tear Proteomics via In-Capillary Digestion for Biomarker Discovery
Tear fluid is emerging as a valuable resource for biomarker discovery, but its low sample volume and dynamic composition pose significant challenges for analytical testing. Most tear proteomics studies have focused on samples collected with Schirmer strips, while capillary tube collection has received less attention. To address these challenges, we developed a novel in-capillary trypsin digestion workflow that requires as little as 0.5 μL of tear fluid for bottom-up shotgun proteomics. This method uses liquid chromatography-tandem mass spectrometry (LC-MS/MS) to identify a higher number of proteins with enhanced efficiency compared to previously reported methods, which typically required 5-10 μL of pooled tear fluid. Using the same microcentrifuge tube for both tear collection and sample processing, this streamlined workflow simplifies sample handling and minimizes both sample loss and experimental errors associated with sample transfer. This method also efficiently reduced sample processing time to under 2 hours prior to overnight trypsin digestion, compared to the 5-8 hours required by other methods. With this workflow, we identified 500-800 proteins per 0.5 μL sample without the need for fractionation, allowing for at least three technical replicates. This optimized workflow greatly enhances the efficiency of tear proteomics for biomarker discovery.