    Study on Combustion Characteristics and Damage of Single-Phase Ground Fault Arc in 10 kV Distribution Network Cable

    by Ziheng Pu, Yiyu Du, Shuai Wang, Zhigang Ren, Kuan Ye, Wei Guo

    The neutral point of a 10 kV distribution network often adopts an arc suppression coil or high resistance grounding mode to ensure the reliability of the power supply. The single-phase grounding fault current is below 10 A, and the distribution network can continue to operate with the fault for up to 2 h. However, long-time arc faults may ignite cables and cause electrical fires, causing further damage to adjacent cables and seriously affecting the safety of the power grid. To study the combustion characteristics of a single-phase grounding fault of a distribution network cable under the action of a long-term small current arc, the cable fault ignition test was carried out by using the arc ignition method of welding tin wire fuses. Then, the temperature distribution of the cable channel in an electrical fire was simulated, based on an FDS simulation, and the damage of adjacent cables under typical layout was further analyzed. The results show that the 10 kV cable was quickly ignited by the high temperature arc within 0.04 s after the breakdown and damage of the cable. Flammable XLPE insulation melted or even dripped off at a high temperature in fire. Thus, the fire spread to both ends when burning. Under the condition of 4–10 A, the maximum flame temperatures above the arc fault point reached 725 °C, 792 °C, 812 °C and 907 °C, respectively. According to the network structure, some protection, such as fireproof tape, needs to be applied directly above the faulty cable when the fault current exceeds 6 A.


  • Open Access

    Study on the Configuration and Fire-Resistant Property of Cable Tunnel Fireproof Clapboard Based on Equivalent Fire Condition Testing

    by Jing Cai, Wei Guo, Hongquan Ji, Huachun Li, Zhigang Ren, Zehua Pan, Yekun Men

    At present, the selection criteria and configuration methods for fireproof clapboards in cable tunnels are not yet perfect, making it difficult to achieve effective fire protection. Therefore, an equivalent fire condition testing method is proposed to analyze the fire-resistant property of fireproof clapboards of different materials. Firstly, a tunnel fire experiment platform was built to carry out the combustion experiment of the high-voltage cable intermediate joint. The cable combustion equivalent fire source device is developed based on the temperature rise characteristics under different combustion conditions. However, the temperature rise characteristics of the equivalent fire source and the actual cable combustion error are within 10%. Then, four typical fireproof clapboards were tested under equivalent fire sources. The results indicate that the organic molded board has the best performance. In addition, factors such as the thickness, side panel height, and installation method of the fireproof clapboards were tested and analyzed. The results indicate that a minimum thickness of 5 mm for the fireproof clapboard and a height of 200 mm for the side panel of the clapboard are necessary to ensure effective protection. The installation method of hoisting fireproof clapboards can effectively extend the protection time by about 30% compared to the flat method.