Zhikang Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Zhikang Zhang has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Qinghui Jin
Ningbo University
2 shared publications - Demin Zhang
State Key Laboratory for Quality and Safety of Agro-products, School of Marine Sciences, Ningbo University, Ningbo 315211, China
1 shared publication - Haojun Yuan
Mechanical and Electrical Engineering School, Zhejiang Fashion Institute of Technology, Ningbo, Zhejiang, China
1 shared publication - Jiawen Yin
Faculty of Electrical Engineering and Computer Science, Ningbo University, Ningbo, China
1 shared publication - Juan Lin
Faculty of Electrical Engineering and Computer Science, Ningbo University, Ningbo, China
1 shared publication - Panhui Yang
Ningbo University
1 shared publication
Latest Publications
- 4 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Label-Free Multifrequency Impedance Detection System for Single-Cell Analysis: A Novel Approach for Hybridoma and Myeloma Cell Differentiation
Hybridoma cell screening is crucial for the production of monoclonal antibodies; however, traditional screening methods are often time-consuming and reliant on antigen-antibody labeling. This study introduces a label-free, single-cell, multi-frequency impedance detection system that innovatively utilizes impedance spectra as a novel physical parameter to differentiate between various hybridoma and myeloma cell types. The sensing device integrates dual-funnel structures with coplanar electrodes, which are respectively utilized for cell capture and impedance measurement. By optimizing the excitation voltage and flow rate, the system effectively reduces measurement errors. The sensing device was validated using polystyrene microbeads of different diameters, yielding coefficients of variation (CV) of 0.0241% and 0.0132%, indicating high measurement stability and repeatability. The system was further validated with two types of hybridoma cells (E5, CD2) and myeloma cells (SP20), and impedance data were analyzed using orthogonal partial least squares discriminant analysis (OPLS-DA) via SIMCA 14.5 software, achieving a model prediction accuracy of 0.974. The results demonstrate that the system can stably and accurately measure cell impedance spectra, and that impedance spectra, as a label-free parameter, can effectively distinguish between different types of hybridoma and myeloma cells, showing great potential for hybridoma cell sorting.
- 4 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Label-Free Multifrequency Impedance Detection System for Single-Cell Analysis: A Novel Approach for Hybridoma and Myeloma Cell Differentiation
Hybridoma cell screening is crucial for the production of monoclonal antibodies; however, traditional screening methods are often time-consuming and reliant on antigen-antibody labeling. This study introduces a label-free, single-cell, multi-frequency impedance detection system that innovatively utilizes impedance spectra as a novel physical parameter to differentiate between various hybridoma and myeloma cell types. The sensing device integrates dual-funnel structures with coplanar electrodes, which are respectively utilized for cell capture and impedance measurement. By optimizing the excitation voltage and flow rate, the system effectively reduces measurement errors. The sensing device was validated using polystyrene microbeads of different diameters, yielding coefficients of variation (CV) of 0.0241% and 0.0132%, indicating high measurement stability and repeatability. The system was further validated with two types of hybridoma cells (E5, CD2) and myeloma cells (SP20), and impedance data were analyzed using orthogonal partial least squares discriminant analysis (OPLS-DA) via SIMCA 14.5 software, achieving a model prediction accuracy of 0.974. The results demonstrate that the system can stably and accurately measure cell impedance spectra, and that impedance spectra, as a label-free parameter, can effectively distinguish between different types of hybridoma and myeloma cells, showing great potential for hybridoma cell sorting.
- 9 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-13
A Novel Life Sign Interpretation System Based on Electrical Impedance Spectroscopy for Swimming Aquatic Animals
In scientific aquaculture, real-time monitoring of the life signs and growth status of aquatic animals can improve the yield and quality of aquatic animals. Currently, the monitoring methods commonly used include optical and acoustic detection, which face problems such as optical interference and high cost, making it difficult to use on a wide scale. This research presents a system based on electrical impedance spectroscopy technology to directly and accurately monitor the life signs of aquatic animals in real-time without any external intervention. The system comprises two components, namely data measurement and data analysis. The former is used to construct the electrical impedance spectroscopy, encompassing a sensing device for measuring impedance and a detection circuit. The latter is a model for interpreting animal life sign parameters, which is used to analyze the impedance spectra and produce judgment results. The sensing device consists of two pairs of electrical impedance spectroscopy measurement sensors arranged vertically at a certain distance. A pre-trained classification model and an online key parameter interpretation model are both components of the interpretation model. Using different fish as test samples, the system is verified to discriminate fish species, numbers, and physical characteristics (swimming speed, shape). The judgment accuracy for both species and different media classifications is 96.2%. The average relative error between the measured and real swimming speeds is 0.15%. The quantity model judgment accuracy is 100%. The average relative error in length of the discrimination of physical signs is 1.63%. The results showed that the system can achieve non-contact, low-cost, high-precision, and real-time detection of swimming aquatic animals, which provides a novel approach for online assessment of the health status of aquatic animals.
- 9 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-13
A Novel Life Sign Interpretation System Based on Electrical Impedance Spectroscopy for Swimming Aquatic Animals
In scientific aquaculture, real-time monitoring of the life signs and growth status of aquatic animals can improve the yield and quality of aquatic animals. Currently, the monitoring methods commonly used include optical and acoustic detection, which face problems such as optical interference and high cost, making it difficult to use on a wide scale. This research presents a system based on electrical impedance spectroscopy technology to directly and accurately monitor the life signs of aquatic animals in real-time without any external intervention. The system comprises two components, namely data measurement and data analysis. The former is used to construct the electrical impedance spectroscopy, encompassing a sensing device for measuring impedance and a detection circuit. The latter is a model for interpreting animal life sign parameters, which is used to analyze the impedance spectra and produce judgment results. The sensing device consists of two pairs of electrical impedance spectroscopy measurement sensors arranged vertically at a certain distance. A pre-trained classification model and an online key parameter interpretation model are both components of the interpretation model. Using different fish as test samples, the system is verified to discriminate fish species, numbers, and physical characteristics (swimming speed, shape). The judgment accuracy for both species and different media classifications is 96.2%. The average relative error between the measured and real swimming speeds is 0.15%. The quantity model judgment accuracy is 100%. The average relative error in length of the discrimination of physical signs is 1.63%. The results showed that the system can achieve non-contact, low-cost, high-precision, and real-time detection of swimming aquatic animals, which provides a novel approach for online assessment of the health status of aquatic animals.