JZJingjing Zhao

Jingjing Zhao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jingjing Zhao has a total of 22 co-authors. Here are the top co-authors by number of shared publications:

  • Fugui Yang

    Institute of High Energy Physics, Chinese Academy of Sciences 2 , Beijing 100049

    1 shared publication
  • Guanyu Qu

    Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei 430022, P. R. China

    1 shared publication
  • Haijun Wang

    Department of Neurosurgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, 1277# Jiefang Avenue, Wuhan, 430022, Hubei, China.

    1 shared publication
  • Han Dong

    Institute of High Energy Physics, Chinese Academy of Sciences 1 , Beijing 100049

    1 shared publication
  • Jiayi Zhou

    Institute of Medical Equipment Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China

    1 shared publication
  • Lei Gao

    Institute of Medical Equipment Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China

    1 shared publication

Latest Publications

  • Open Access

    Two-step thermocompression bonding of High-NA-compatible glass microfluidic chips for imaging flow cytometry

    by Lingqi Jiang, Yong Han, Lei Gao, Shenglan Yao, Linlin Liu, Wankang Zhai, Jiayi Zhou, Sen Peng, Jingjing Zhao, Zheng You

    Imaging flow cytometry is rapidly developing toward higher spatial resolution and enhanced capability for resolving subcellular structures, which makes such systems increasingly dependent on high-numerical-aperture objectives for higher-resolution imaging, thereby imposing higher requirements on the stability of three-dimensional hydrodynamic focusing, the quality of optical interfaces, and the structural compatibility of microfluidic chips. In this work, we propose a low-cost fabrication method for glass microfluidic chips for imaging flow cytometry, based on laser processing and a two-step thermocompression bonding strategy. By separating microchannel pre-bonding from overall encapsulation, this method preserves the structural integrity of the microchannels while constructing an optical observation window compatible with high-numerical-aperture objectives, thereby meeting the adaptation requirements of mainstream microscope objectives in terms of working distance and mechanical interfacing. Experimental results show that the optical detection region of the fabricated chip exhibits nanoscale surface quality and good optical transmission performance. Flow imaging experiments further demonstrate that the chip achieved stable three-dimensional hydrodynamic focusing and high-quality fluorescence imaging under high-speed flow conditions, and that the resulting signals exhibited a narrow distribution with low fluctuation, indicating good detection stability and imaging reliability. The study shows that the proposed two-step thermocompression bonding process achieves a balance among the optical performance, structural integrity, and manufacturability of glass microfluidic chips, providing a feasible solution for the fabrication of high-throughput, low-cost, and biosafe chips for imaging flow cytometry.


  • Open Access

    Label-free lipid droplet imaging for rapid nonalcoholic-fatty-liver-disease (NAFLD) analysis using dynamic full-field optical coherence tomography

    by Xiaobo Qin, Ming Yan, Yanting Wu, Guanyu Qu, Shuyue Zheng, Haijun Wang, Jingjing Zhao

    Non-alcoholic fatty liver disease (NAFLD) is one of the most prevalent chronic liver diseases globally. Hepatic steatosis, characterized by the accumulation of lipid droplets (LDs), is a hallmark of NAFLD. Traditional pathology and specific fluorescent dye imaging have difficulty in observing LDs in their natural state within hepatocytes rapidly. In this study, a customized dynamic full-field optical coherence tomography (D-FFOCT) system was applied for label-free visualization of LDs and rapid ex vivo assessment of NAFLD. Two groups of mice fed the methionine choline-deficient (MCD) diet for one week and two weeks, respectively, underwent dual-mode FF-OCT imaging and comparative quantitative analysis. The subcellular structures—including nuclei and small LDs—were clearly observed. Quantitative analysis of D-FFOCT results revealed significant quantitative profiles in LD characteristics across various NAFLD stages. Furthermore, imaging of a non-alcoholic steatohepatitis (NASH) mouse model fed a high-fat diet for 14 weeks provided insights into the identification of inflammatory cells via D-FFOCT. These results indicate that D-FFOCT can effectively resolve the subcellular structure and quantify LDs in NAFLD models across varying severities, thereby demonstrating its potential for rapid NAFLD assessment and pharmaceutical development applications.


  • Development of a high-precision long trace profiler utilizing shear measurements

    by Xiaowen Cui, Ming Wu, Han Dong, Xiaobo Qin, Fugui Yang, Xiaowei Zhang, Ming Li, Weifan Sheng

    Compensating for the pitch error in the scanning movement is a fundamental issue when conducting large-scale surface shape measurements with deflectometric profilers. This paper presents a new long trace profiler employing a shearing measurement technique. In this setup, the optical head and the mirror under test are mounted on two independent parallel movable air-bearing carriages to enable shearing and scanning movements separately. The distance between the optical head and the tested mirror remains fixed, effectively minimizing the influence of system errors resulting from imperfections in optical devices. Simulation studies show that the double shear measurement method with a low-spatial-frequency filtering process can effectively mitigate high-frequency angular measurement errors introduced by the instability of the air-bearing stage. Experimental tests conducted on flat mirrors demonstrated a precision of less than 50 nrad rms, thereby confirming the robustness of the system.