Natalia Jakubiak
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Natalia Jakubiak has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Dariusz Gaweł
Faculty of Civil Engineering and Architecture, Lublin University of Technology, 20-618 Lublin, Poland
2 shared publications - Łukasz Guz
Faculty of Environmental Engineering, Lublin University of Technology, 20-618 Lublin, Poland
2 shared publications - Aleksandra Sztorc
Department of Contemporary Architecture, Faculty of Civil Engineering and Architecture, Lublin University of Technology
1 shared publication - Anna Halicka
Politechnika Lubelska Wydział Budownictwa i Architektury
1 shared publication - Bartosz Przysucha
Faculty of Management, Lublin University of Technology, 20-618 Lublin, Poland
1 shared publication - Bartłomiej Kwiatkowski
Faculty of Civil Engineering and Architecture, Lublin University of Technology, 20-618 Lublin, Poland
1 shared publication
Latest Publications
- Open Access
Playgrounds as Scenes of Everyday Childhood: Scene Profiles and Experienced Child-Friendliness in Multifamily Housing
Playgrounds in multifamily housing are often treated as sufficient evidence that housing estates meet children’s needs, although similarly equipped spaces may offer different conditions for everyday use. This study applies an author-developed adaptation of the Scene Theory 5+3+1 model to eight playgrounds in two contrasting residential areas in Lublin, Poland: modernist LSM and contemporary Węglinek. Scene profiles were developed from field audits and observations conducted independently by two researchers (90.6% agreement; Cohen’s κ = 0.836). The “+1” experiential core was determined from 46 caregiver questionnaires, while the responses of 46 children were analysed separately. At the four LSM playgrounds, 27 of 32 dimension ratings were positive, compared with 10 of 32 at the four Węglinek playgrounds; differences mainly concerned relationships with greenery and surroundings rather than equipment. All four LSM playgrounds and one Węglinek playground obtained a positive experiential core. Similar core categories co-occurred with differing scene profiles, although some contrasts depended on the classification rules adopted. Thematically related child and caregiver response categories converged more often at the LSM playgrounds; where they diverged, children more frequently gave the more positive response. The findings suggest the potential usefulness of analysing scene profiles, caregiver assessments and children’s responses separately.
Open AccessPlaygrounds as Scenes of Everyday Childhood: Scene Profiles and Experienced Child-Friendliness in Multifamily Housing
Playgrounds in multifamily housing are often treated as sufficient evidence that housing estates meet children’s needs, although similarly equipped spaces may offer different conditions for everyday use. This study applies an author-developed adaptation of the Scene Theory 5+3+1 model to eight playgrounds in two contrasting residential areas in Lublin, Poland: modernist LSM and contemporary Węglinek. Scene profiles were developed from field audits and observations conducted independently by two researchers (90.6% agreement; Cohen’s κ = 0.836). The “+1” experiential core was determined from 46 caregiver questionnaires, while the responses of 46 children were analysed separately. At the four LSM playgrounds, 27 of 32 dimension ratings were positive, compared with 10 of 32 at the four Węglinek playgrounds; differences mainly concerned relationships with greenery and surroundings rather than equipment. All four LSM playgrounds and one Węglinek playground obtained a positive experiential core. Similar core categories co-occurred with differing scene profiles, although some contrasts depended on the classification rules adopted. Thematically related child and caregiver response categories converged more often at the LSM playgrounds; where they diverged, children more frequently gave the more positive response. The findings suggest the potential usefulness of analysing scene profiles, caregiver assessments and children’s responses separately.
- Open Access
Internal Wall Cooling by Reversed Airflow in Ventilation Ducts After Building Retrofit: A Case Study of a Higher Education Facility
This study investigated an unusual yet practically significant side effect of the thermal retrofit of educational buildings, namely the intensive cooling of internal walls containing uninsulated ventilation ducts. Malfunctioning gravity ventilation led to a reversal of airflow direction, resulting in the inflow of cold air through internal ducts and a deterioration of thermal comfort in the rooms. The cooled zones were identified during thermographic surveys carried out using a FLIR E8-XT camera. Numerical heat transfer analyses were performed in THERM 8.1 (LBNL), while the thermal performance of the building and its seasonal heating demand were calculated in Audytor OZC (Sankom). Three variants were compared: (1) standard design conditions, (2) scenario accounting for the cooling effect of internal walls due to reverse flow of ventilation air, and (3) mechanical ventilation with heat recovery (MVHR). Under the analysed actual operating conditions, the transmission heat loss increased from 27,479 W to 52,473 W, while the annual heating demand rose by 57.6% from 71.3 to 112.4 kWh/(m3∙year). The indoor air temperature decreased by approximately 3 ÷ 7 °C (depending of the space), while the surface temperature near the ducts fell to 5.1 ÷ 12.6 °C at an outdoor temperature of −13 °C. The implementation of MVHR (η = 75%), compared to current situation, reduced the overall heat loss coefficient by 63.9% from 3934.225 to 1417.825 W/K and the annual heating demand by 70.3% from 112.4 to 33.3 kWh/(m3∙year). The results confirm that uncontrolled airflow through internal ventilation ducts may lead to substantial heat losses and localised cooling zones in building elements, effectively acting as thermal bridges.
Open AccessInternal Wall Cooling by Reversed Airflow in Ventilation Ducts After Building Retrofit: A Case Study of a Higher Education Facility
This study investigated an unusual yet practically significant side effect of the thermal retrofit of educational buildings, namely the intensive cooling of internal walls containing uninsulated ventilation ducts. Malfunctioning gravity ventilation led to a reversal of airflow direction, resulting in the inflow of cold air through internal ducts and a deterioration of thermal comfort in the rooms. The cooled zones were identified during thermographic surveys carried out using a FLIR E8-XT camera. Numerical heat transfer analyses were performed in THERM 8.1 (LBNL), while the thermal performance of the building and its seasonal heating demand were calculated in Audytor OZC (Sankom). Three variants were compared: (1) standard design conditions, (2) scenario accounting for the cooling effect of internal walls due to reverse flow of ventilation air, and (3) mechanical ventilation with heat recovery (MVHR). Under the analysed actual operating conditions, the transmission heat loss increased from 27,479 W to 52,473 W, while the annual heating demand rose by 57.6% from 71.3 to 112.4 kWh/(m3∙year). The indoor air temperature decreased by approximately 3 ÷ 7 °C (depending of the space), while the surface temperature near the ducts fell to 5.1 ÷ 12.6 °C at an outdoor temperature of −13 °C. The implementation of MVHR (η = 75%), compared to current situation, reduced the overall heat loss coefficient by 63.9% from 3934.225 to 1417.825 W/K and the annual heating demand by 70.3% from 112.4 to 33.3 kWh/(m3∙year). The results confirm that uncontrolled airflow through internal ventilation ducts may lead to substantial heat losses and localised cooling zones in building elements, effectively acting as thermal bridges.
- Open Access
- 28 November 2025
- Published by Uniwersytet Jagiellonski - Wydawnictwo Uniwersytetu Jagiellonskiego in Środowisko Mieszkaniowe/Housing Environment
- Vol. 53 (4) , 64-76
Evaluation of Thermal Retrofit Variants for Facades in High-Rise Large-Panel Residential Buildings: Impact on Energy Demand Using the BESM Model
This article examines the effectiveness of secondary thermal retrofitting in high-rise buildings constructed using large-panel technology and presents a model for evaluating the efficiency of facade modernisation and aesthetic enhancement methods, with particular emphasis on their energy performance. Three retrofit variants were analysed: increased glazing of balconies, aluminium-clad balcony facades, and a fully glazed facade. Calculations were performed using Audytor software by Sankom, based on an energy audit and in-situ measurements, taking into account the U -value [W/(m 2 ·K)], annual energy demand EHV [kWh/m 2 ·year], cost C [€/m 2 ], and carbon footprint eCO 2 [kgCO 2 /(m 2 ·year)]. The results show that Variant 2 (V2) achieves the greatest energy consumption reduction (32.1%), while Variant 1 (V1) provides the best insulation performance ( U = 0.149 W/m 2 K) and the highest BESM index (1.109). Despite its higher cost (155 €/m²), V2 significantly improves both the building’s energy efficiency and aesthetics. Optimising thermal retrofit methods is a key factor in adapting large-panel buildings to contemporary standards and enhancing residents’ quality of life.
- 28 November 2025
- Published by Uniwersytet Jagiellonski - Wydawnictwo Uniwersytetu Jagiellonskiego in Środowisko Mieszkaniowe/Housing Environment
- Vol. 53 (4) , 64-76
Open AccessEvaluation of Thermal Retrofit Variants for Facades in High-Rise Large-Panel Residential Buildings: Impact on Energy Demand Using the BESM Model
This article examines the effectiveness of secondary thermal retrofitting in high-rise buildings constructed using large-panel technology and presents a model for evaluating the efficiency of facade modernisation and aesthetic enhancement methods, with particular emphasis on their energy performance. Three retrofit variants were analysed: increased glazing of balconies, aluminium-clad balcony facades, and a fully glazed facade. Calculations were performed using Audytor software by Sankom, based on an energy audit and in-situ measurements, taking into account the U -value [W/(m 2 ·K)], annual energy demand EHV [kWh/m 2 ·year], cost C [€/m 2 ], and carbon footprint eCO 2 [kgCO 2 /(m 2 ·year)]. The results show that Variant 2 (V2) achieves the greatest energy consumption reduction (32.1%), while Variant 1 (V1) provides the best insulation performance ( U = 0.149 W/m 2 K) and the highest BESM index (1.109). Despite its higher cost (155 €/m²), V2 significantly improves both the building’s energy efficiency and aesthetics. Optimising thermal retrofit methods is a key factor in adapting large-panel buildings to contemporary standards and enhancing residents’ quality of life.
- Open Access
- 8 October 2024
- Published by University of Zielona Góra, Poland in Civil and Environmental Engineering Reports
- Vol. 34 (4) , 22-31
Concepts of Reusing Wind Turbine Blades in Civil Engineering Constructions
Wind turbines have become an important source of renewable energy in recent years, but recycling them is difficult due to their material properties. The paper indicates the possibility of using turbine blades to produce elements that can be filled with concrete and used as members of small geotechnical structures: retaining walls, point and well foundations, foundations for railings, fences, road signs, etc., as well as excavation linings and shoring walls. In these solutions, concrete-filled elements of turbine blades constitute a form (formwork) for concrete, protecting it against environmental influences, and can also cooperate with concrete in transferring loads.
- 8 October 2024
- Published by University of Zielona Góra, Poland in Civil and Environmental Engineering Reports
- Vol. 34 (4) , 22-31
Open AccessConcepts of Reusing Wind Turbine Blades in Civil Engineering Constructions
Wind turbines have become an important source of renewable energy in recent years, but recycling them is difficult due to their material properties. The paper indicates the possibility of using turbine blades to produce elements that can be filled with concrete and used as members of small geotechnical structures: retaining walls, point and well foundations, foundations for railings, fences, road signs, etc., as well as excavation linings and shoring walls. In these solutions, concrete-filled elements of turbine blades constitute a form (formwork) for concrete, protecting it against environmental influences, and can also cooperate with concrete in transferring loads.