Futoshi Nakamura
Research Subjects
Futoshi Nakamura has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Mana Hasegawa
Division of Oral Physiology, Faculty of Dentistry, Niigata University Graduate School of Medical and Dental Sciences, Niigata 951-8514, Japan
2 shared publications - Mizuki Hoshino2 shared publications
- Noritaka Fujii
Division of Dental Clinical Education, Faculty of Dentistry, Niigata University Graduate School of Medical and Dental Sciences, Niigata 951-8514, Japan
2 shared publications - Sayaka Tsuzuno2 shared publications
- Takumi Sato
General Dentistry and Clinical Education Unit, Niigata University Medical and Dental Hospital, Niigata 951-8520, Japan
2 shared publications
Latest Publications
- 27 February 2026
- Published by MediHealth Academy in Journal of Dental Sciences and Education
- Vol. 4 (1) , 11-16
Development of a new teaching tool for visualizing invisible tips by adjusting full dentures
Aims: Dental clinical skills include subtle techniques, such as applying an appropriate amount of force depending on the procedure. This study investigated the training effects of using pressure sensors on force magnitude control during the dental procedure. Methods: Forty-two dental trainees participated in this study. The experimental task was a fit test, assessing the pressure contact of a denture against the mandible. The force applied by each participant was measured using a modified mannequin equipped with a digital force gauge. Fit test training was performed under conditions specifying the presence or absence of fit test material and various degrees of force, with 50 N set as the standard. After training, the ability to control force magnitude was statistically evaluated by examining the error between the specified and actual values. Results: The presence of the fit test material did not affect the force magnitude, and the time required decreased in proportion to the number of trials. Initially, not all participants were able to apply 50 N without special instructions. However, after training, the measured values exceeded 50 N. The error from the target value was significantly larger when 70 N was designated compared to 50 N. Errors between the specified and actual values obtained at 30–60 N exhibited a decreasing trend in each successive cycle. Conclusion: Visualized numerical data are effective for developing practical force control. This form of experiential learning may contribute to the early retention of basic dental skills.
- 27 February 2026
- Published by MediHealth Academy in Journal of Dental Sciences and Education
- Vol. 4 (1) , 11-16
Development of a new teaching tool for visualizing invisible tips by adjusting full dentures
Aims: Dental clinical skills include subtle techniques, such as applying an appropriate amount of force depending on the procedure. This study investigated the training effects of using pressure sensors on force magnitude control during the dental procedure. Methods: Forty-two dental trainees participated in this study. The experimental task was a fit test, assessing the pressure contact of a denture against the mandible. The force applied by each participant was measured using a modified mannequin equipped with a digital force gauge. Fit test training was performed under conditions specifying the presence or absence of fit test material and various degrees of force, with 50 N set as the standard. After training, the ability to control force magnitude was statistically evaluated by examining the error between the specified and actual values. Results: The presence of the fit test material did not affect the force magnitude, and the time required decreased in proportion to the number of trials. Initially, not all participants were able to apply 50 N without special instructions. However, after training, the measured values exceeded 50 N. The error from the target value was significantly larger when 70 N was designated compared to 50 N. Errors between the specified and actual values obtained at 30–60 N exhibited a decreasing trend in each successive cycle. Conclusion: Visualized numerical data are effective for developing practical force control. This form of experiential learning may contribute to the early retention of basic dental skills.
- Open Access
- 21 September 2024
- Published by MediHealth Academy in Journal of Dental Sciences and Education
- Vol. 2 (3) , 59-63
Quantitative analysis of impression-taking performance - a pilot study to visualize invisible technical steps in dental procedures
Aims: Dental procedures involve intricate techniques that can be challenging to visualize, often hindering imitation and assessment. In this study, the impression-taking performance of abutment teeth was quantitatively analyzed to create objective indexes for dental skill education. Methods: Participants were divided into two groups of different clinical experience levels: 10 dentists and 10 dental students. An aluminum model of abutment teeth was employed to simplify the experiment. An optical motion capture system (VICON, Oxford, UK) measured participants’ movements. The impression accuracy, time length on the analyzed section, impression material pouring speed, total amount of impression material used, and syringe tip trajectory were evaluated. Fisher’s exact test and Mann–Whitney U test were used to compare the two groups’ results (?=0.05). Results: In the dentist group, there were few apparent failures and a high impression accuracy. The amount of impression material dispensed tended to be larger in the dentist group, with longer practice time and slower syringe movement speed. This suggested that the inexperienced participants were sufficiently unable to pour out the impression material. The syringe tip trajectories were not significantly different between the groups. An instructor’s advice is often limited to abstract feedback; therefore, specific suggestions might assist in effective skill education. Conclusion: It is possible to quantitatively analyze impression-taking performance and provide helpful information for dental skill education by using this system.
- 21 September 2024
- Published by MediHealth Academy in Journal of Dental Sciences and Education
- Vol. 2 (3) , 59-63
Open AccessQuantitative analysis of impression-taking performance - a pilot study to visualize invisible technical steps in dental procedures
Aims: Dental procedures involve intricate techniques that can be challenging to visualize, often hindering imitation and assessment. In this study, the impression-taking performance of abutment teeth was quantitatively analyzed to create objective indexes for dental skill education. Methods: Participants were divided into two groups of different clinical experience levels: 10 dentists and 10 dental students. An aluminum model of abutment teeth was employed to simplify the experiment. An optical motion capture system (VICON, Oxford, UK) measured participants’ movements. The impression accuracy, time length on the analyzed section, impression material pouring speed, total amount of impression material used, and syringe tip trajectory were evaluated. Fisher’s exact test and Mann–Whitney U test were used to compare the two groups’ results (?=0.05). Results: In the dentist group, there were few apparent failures and a high impression accuracy. The amount of impression material dispensed tended to be larger in the dentist group, with longer practice time and slower syringe movement speed. This suggested that the inexperienced participants were sufficiently unable to pour out the impression material. The syringe tip trajectories were not significantly different between the groups. An instructor’s advice is often limited to abstract feedback; therefore, specific suggestions might assist in effective skill education. Conclusion: It is possible to quantitatively analyze impression-taking performance and provide helpful information for dental skill education by using this system.