Shijue Gao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shijue Gao has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Xuejun Ma
National Key Laboratory of Intelligent Tracking and Forecasting for Infectious Diseases, NHC Key Laboratory of Medical Virology and Viral Diseases, National Institute for Viral Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing 102206, China
3 shared publications - Yanqing Tie
Department of Clinical Laboratory, Hebei General Hospital, Shijiazhuang 050051, China
3 shared publications - Yuxin Wang
Department of Clinical Laboratory, Hebei General Hospital, Shijiazhuang 050051, China
3 shared publications - Duoxiao Zhang
Graduate School, Hebei North University, Zhangjiakou 075000, China
2 shared publications - Jianing Wu
Graduate School, Hebei North University, Zhangjiakou 075000, China
2 shared publications - Shihao Jiao
Department of Clinical Laboratory, Hebei General Hospital, Shijiazhuang 050051, China
2 shared publications
Latest Publications
- Open Access
A Multiplex One-Tube Nested Real-Time PCR Assay for the Point-of-Care Testing of Infectious Meningitis
In this study, we developed a multiplex one-tube nested real-time fluorescent quantitative PCR (mONRT-PCR) assay integrated with a portable, fully automated nucleic acid point-of-care testing (POCT) platform for the detection of Haemophilus influenzae (H. influenzae), Listeria monocytogenes (L. monocytogenes), and Cryptococcus neoformans (C. neoformans) in cerebrospinal fluid (CSF). The assay enables nested amplification within a closed system using conventional primers and probes, thereby reducing operational complexity and minimizing contamination risk. Analytical evaluation demonstrated limits of detection of 100 copies/μL for H. influenzae and L. monocytogenes, and 101 copies/μL for C. neoformans using recombinant plasmids, as well as 10−7 to 10−6 ng/μL using genomic DNA. No cross-reactivity was observed when tested against a panel of 17 common non-target microorganisms encountered in clinical microbiology laboratories. In simulated CSF samples, the assay maintained detectable amplification at low pathogen concentrations. When implemented on the POCT platform, detection limits reached 5, 10, and 50 CFU/mL for the three pathogens, respectively. Clinical evaluation using 43 CSF samples showed almost perfect agreement with conventional qPCR (κ = 0.861, p < 0.001). Notably, additional C. neoformans detections were observed by mONRT-PCR-POCT compared with qPCR, suggesting improved sensitivity under clinical conditions. The assay yielded results within approximately 1 h and 47 min. These findings indicate that the proposed assay provides a rapid, sensitive, and integrated approach for meningitis pathogen detection, while maintaining a practical balance between analytical performance and operational simplicity. Further validation in larger cohorts is warranted.
Open AccessA Multiplex One-Tube Nested Real-Time PCR Assay for the Point-of-Care Testing of Infectious Meningitis
In this study, we developed a multiplex one-tube nested real-time fluorescent quantitative PCR (mONRT-PCR) assay integrated with a portable, fully automated nucleic acid point-of-care testing (POCT) platform for the detection of Haemophilus influenzae (H. influenzae), Listeria monocytogenes (L. monocytogenes), and Cryptococcus neoformans (C. neoformans) in cerebrospinal fluid (CSF). The assay enables nested amplification within a closed system using conventional primers and probes, thereby reducing operational complexity and minimizing contamination risk. Analytical evaluation demonstrated limits of detection of 100 copies/μL for H. influenzae and L. monocytogenes, and 101 copies/μL for C. neoformans using recombinant plasmids, as well as 10−7 to 10−6 ng/μL using genomic DNA. No cross-reactivity was observed when tested against a panel of 17 common non-target microorganisms encountered in clinical microbiology laboratories. In simulated CSF samples, the assay maintained detectable amplification at low pathogen concentrations. When implemented on the POCT platform, detection limits reached 5, 10, and 50 CFU/mL for the three pathogens, respectively. Clinical evaluation using 43 CSF samples showed almost perfect agreement with conventional qPCR (κ = 0.861, p < 0.001). Notably, additional C. neoformans detections were observed by mONRT-PCR-POCT compared with qPCR, suggesting improved sensitivity under clinical conditions. The assay yielded results within approximately 1 h and 47 min. These findings indicate that the proposed assay provides a rapid, sensitive, and integrated approach for meningitis pathogen detection, while maintaining a practical balance between analytical performance and operational simplicity. Further validation in larger cohorts is warranted.
- Open Access
A Nested PCR-Based Point of Care Testing of Multiplex Pathogens Associated with Bloodstream Infection
Bloodstream infections (BSI) carry high mortality, but traditional blood culture is too slow for urgent clinical needs. This study aims to develop a rapid point-of-care testing assay based on one-tube multiplex nested polymerase chain reaction (PCR) (OM-NPCR-POCT) for early diagnosis of three pathogens in bloodstream infection patients: Escherichia coli (ECO), Klebsiella pneumoniae (KPN), and Streptococcus pneumoniae (SPN). The analytical sensitivity of the one-tube multiplex nested PCR (OM-NPCR) was evaluated using recombinant bacterial plasmids. The analytical sensitivity of the OM-NPCR-POCT assay was assessed using simulated samples. The clinical performance was evaluated in 90 clinical blood samples, with results compared to conventional quantitative PCR (qPCR). Finally, the agreement between the two detection methods was assessed via Kappa analysis. The limits of detection (LODs), calculated from serial dilution experiments, were 4, 2, and 1 copies/μL for plasmids ECO, KPN, and SPN, respectively. The OM-NPCR-POCT assay achieved LODs of 20, 10, and 10 CFU/mL for ECO, KPN, and SPN in simulated samples, with a total testing time of approximately 2 h. The clinical evaluation of OM-NPCR-POCT demonstrates consistency with conventional qPCR while exhibiting higher sensitivity. This method has potential as a rapid diagnostic tool for early bloodstream infection detection.
Open AccessA Nested PCR-Based Point of Care Testing of Multiplex Pathogens Associated with Bloodstream Infection
Bloodstream infections (BSI) carry high mortality, but traditional blood culture is too slow for urgent clinical needs. This study aims to develop a rapid point-of-care testing assay based on one-tube multiplex nested polymerase chain reaction (PCR) (OM-NPCR-POCT) for early diagnosis of three pathogens in bloodstream infection patients: Escherichia coli (ECO), Klebsiella pneumoniae (KPN), and Streptococcus pneumoniae (SPN). The analytical sensitivity of the one-tube multiplex nested PCR (OM-NPCR) was evaluated using recombinant bacterial plasmids. The analytical sensitivity of the OM-NPCR-POCT assay was assessed using simulated samples. The clinical performance was evaluated in 90 clinical blood samples, with results compared to conventional quantitative PCR (qPCR). Finally, the agreement between the two detection methods was assessed via Kappa analysis. The limits of detection (LODs), calculated from serial dilution experiments, were 4, 2, and 1 copies/μL for plasmids ECO, KPN, and SPN, respectively. The OM-NPCR-POCT assay achieved LODs of 20, 10, and 10 CFU/mL for ECO, KPN, and SPN in simulated samples, with a total testing time of approximately 2 h. The clinical evaluation of OM-NPCR-POCT demonstrates consistency with conventional qPCR while exhibiting higher sensitivity. This method has potential as a rapid diagnostic tool for early bloodstream infection detection.
- Open Access
- 12 October 2024
- Published by MDPI AG in Tropical Medicine and Infectious Disease
- Vol. 9 (10) , 240
Field-Applicable Loop-Mediated Isothermal Amplification for the Detection of Seven Common Human Papillomavirus Subtypes
Persistent HPV infection is a major risk factor for the subsequent development of cervical cancer. LAMP is simple and suitable for field detection in the resource-limited settings. In this study, hydroxy naphthol blue (HNB)-based visual LAMP and evagreen-based fluorescent LAMP coupled with a microfluidic chip (LAMP-chip) were established for the field detection of seven subtypes of HPV. The analytical sensitivity was 19–233 copies/reaction. The overall clinical sensitivity was 97.35% for visual LAMP and 98.23% for LAMP-chip. Both LAMP assays exhibited 100% specificity and were completed in less than 50 min. Additionally, both assays did not require complicated nucleic acid extraction and purification steps. A complete quality control monitoring system (including internal control, positive quality control and negative control) in the LAMP assays further ensured the credibility of the results. Our findings demonstrated that the proposed LAMP assays have the potential to be applied in the testing of common HPV DNA in field investigations (visual LAMP) or within communities and primary health centers (LAMP-chip).
- 12 October 2024
- Published by MDPI AG in Tropical Medicine and Infectious Disease
- Vol. 9 (10) , 240
Open AccessField-Applicable Loop-Mediated Isothermal Amplification for the Detection of Seven Common Human Papillomavirus Subtypes
Persistent HPV infection is a major risk factor for the subsequent development of cervical cancer. LAMP is simple and suitable for field detection in the resource-limited settings. In this study, hydroxy naphthol blue (HNB)-based visual LAMP and evagreen-based fluorescent LAMP coupled with a microfluidic chip (LAMP-chip) were established for the field detection of seven subtypes of HPV. The analytical sensitivity was 19–233 copies/reaction. The overall clinical sensitivity was 97.35% for visual LAMP and 98.23% for LAMP-chip. Both LAMP assays exhibited 100% specificity and were completed in less than 50 min. Additionally, both assays did not require complicated nucleic acid extraction and purification steps. A complete quality control monitoring system (including internal control, positive quality control and negative control) in the LAMP assays further ensured the credibility of the results. Our findings demonstrated that the proposed LAMP assays have the potential to be applied in the testing of common HPV DNA in field investigations (visual LAMP) or within communities and primary health centers (LAMP-chip).