MOMarie Oesten

Marie Oesten

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Marie Oesten has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    PEPbench—Open, Reproducible, and Systematic Benchmarking of Automated Pre‐Ejection Period Extraction Algorithms

    by Robert Richer, Julia Jorkowitz, Sebastian Stühler, Luca Abel, Miriam Kurz, Marie Oesten, Stefan G. Griesshammer, Nils C. Albrecht, Arne Küderle, Christoph Ostgathe, et al.

    The pre‐ejection period (PEP) is a widely used cardiac parameter in psychophysiology that reflects the duration between the onset of ventricular depolarization and the opening of the aortic valve. PEP is often used as a marker of cardiac sympathetic nervous system (SNS) activity, particularly in within‐subject comparisons under similar hemodynamic conditions. While many algorithms for automated PEP extraction from electrocardiography (ECG) and impedance cardiography (ICG) signals (more precisely, its first derivative, dZ / dt ) have been proposed in literature, they have not been systematically benchmarked. This lack of standardized algorithm comparisons originates from the absence of open‐source algorithms and annotated datasets for evaluating PEP extraction algorithms. To address this issue, we introduce PEPbench , an open‐source Python package with different Q‐peak and B‐point detection algorithms from literature that can be combined to create comprehensive PEP extraction pipelines, and a standardized framework for evaluating PEP extraction algorithms. We use PEPbench to systematically compare 108 different algorithm combinations. All combinations are evaluated on two datasets with manually annotated Q‐peaks and B‐points, which we make publicly available as the first datasets with reference PEP annotations. Our results show that the algorithms can differ vastly in their performance and that B‐point detection algorithms introduce a considerable amount of error. Thus, we suggest that automated PEP extraction algorithms should be used with caution on a beat‐to‐beat level as their error rates are relatively high. This highlights the need for open and reproducible benchmarking frameworks for PEP extraction algorithms to improve the quality of research findings in the field of psychophysiology. With PEPbench , we aim to take a first step toward this goal and encourage other researchers to engage in the evaluation of PEP extraction algorithms by contributing algorithms, data, and annotations. We hope to establish a community‐driven platform, fostering innovation and collaboration in the field of psychophysiology and beyond.


  • Open Access

    Vital Insights: How Radar-Based Monitoring Can Enhance Symptom Management in Palliative Care

    by Thanh Trúc Trần, Julia Yip, Marie Oesten, Stefan G. Griesshammer, Nils C. Albrecht, Maria Heckel, Bjoern M. Eskofier, Alexander Koelpin, Christoph Ostgathe, Tobias Steigleder

    Context: Palliative care prioritizes patients’ quality of life with symptom management, personal care, and minimal technology use to respect privacy. However, assessing symptoms, particularly for patients near the end of life who often are unable to communicate, mostly depends on observation by healthcare providers, which may lack completeness and objectivity. Objectives: Non-invasive radar-based monitoring of heart rate (HR) and respiration rate (RR) offers potential for detecting symptoms without compromising palliative care principles. Methods: We used a multi-radar system placed under patients’ mattresses to continuously monitor HRs and RRs in a palliative care ward by tracking body surface movement. Data on symptom burden, including timing and severity, were collected via patient self-reports (MIDOS 2 ) and staff observations (HOPE). The relationship between radar-derived vital signs and distress-related symptom burden changes over hours, as well as medication effects following their peak impact, was analyzed using various statistical methods. Results: Our findings show that HR and RR increase over the course of hours during symptom exacerbation (HR: +2.8 bpm, RR: +0.7 brpm) and decrease with amelioration (HR: –1.8 bpm, RR: –0.2 brpm), with a significant relationship observed between HR and symptom exacerbation (p=0.002). Additionally, HR trends suggested variability potentially related to medication effects, warranting further study. Conclusion: Radar-based monitoring holds promise for burden-free vital sign monitoring in palliative care and assisting healthcare professionals in symptom detection. However, physical activity and environmental factors may affect measurements and medication effects require further investigation. Additional research is needed to refine this technology for clinical use.

  • Open Access

    PEPbench -- Open, Reproducible, and Systematic Benchmarking of Automated Pre-Ejection Period Extraction Algorithms

    by Robert Richer, Julia Jorkowitz, Sebastian Stühler, Luca Abel, Miriam Kurz, Marie Oesten, Stefan G. Griesshammer, Nils C. Albrecht, Arne Küderle, Christoph Ostgathe, et al.

    The pre-ejection period (PEP) is a widely used cardiac parameter in psychophysiological research that reflects the duration between the onset of ventricular depolarization and the opening of the aortic valve and is an established marker of sympathetic nervous system activity. While many algorithms for automated PEP extraction from electrocardiography (ECG) and impedance cardiography (ICG) signals have been proposed in the literature, they have not been systematically compared against each other. This lack of standardized algorithm comparisons is due to the absence of open-source algorithms and annotated datasets for evaluating PEP extraction algorithms. To address this issue, we introduce PEPbench , an open-source Python package with different Q-peak and B-point detection algorithms from the literature that can be combined to form comprehensive PEP extraction pipelines, and a standardized framework for evaluating PEP extraction algorithms. We use PEPbench to systematically compare 90 different algorithm combinations. All combinations are evaluated on datasets from two different studies with manually annotated Q-peaks and B-points, which we make publicly available as the first datasets with reference PEP annotations. Our results show that the algorithms can differ vastly in their performance and that the B-point detection algorithms introduce a considerable amount of error. Thus, we suggest that automated PEP extraction algorithms should be used with caution on a beat-to-beat level as their error rates are still relatively high. This highlights the need for open and reproducible benchmarking frameworks for PEP extraction algorithms to improve the quality of research findings in the field of psychophysiology. With PEPbench , we aim to take a first step towards this goal and encourage other researchers to engage in the evaluation of PEP extraction algorithms by contributing algorithms, data, and annotations. Ultimately, we hope to establish a community-driven platform, fostering innovation and collaboration in the field of psychophysiology and beyond.

  • Systematic Investigation of Heart Sound Propagation Using Continuous Wave Radar

    by Marie Oesten, Luca Abel, Nils C. Albrecht, Robert Richer, Dominik Langer, Stefan G. Griesshammer, Khalida Ghanem, Tobias Steigleder, Christoph Ostgathe, Alexander Koelpin, et al.

    Monitoring the propagation of mechanical cardiac signals throughout the body is crucial for assessing cardiovascular health. A common drawback of current gold standard methods for vital sign monitoring is the necessity for continuous skin contact. Radar-based sensing offers a promising alternative by enabling contactless measurement of cardiac activity, including heart sound signals. As previous research has primarily focused on deriving signals from proximal body regions, insights into heart sound propagation to peripheral areas are lacking. To address this, we systematically investigated whether radar-based heart sound detection and propagation measurement is feasible across the whole body. We recorded heart sounds in N=22 participants sequentially at eleven locations using a custom-built continuous-wave radar system and phonocardiogram as heart sound gold standard. Additionally, an electrocardiogram was acquired as reference for overall heart activity. After synchronization and preprocessing, we manually segmented the heart sounds and extracted temporal characteristics from ensemble-averaged signals. Our findings show that heart sounds can be detected across the entire body with the radar-based as well as the gold standard system. Furthermore, the heart sounds' temporal characteristics vary between measurement locations. As the distance to the heart increases, we observed significantly increased propagation time intervals. This finding is consistent across both systems, exhibiting a strong agreement for the first heart sound ($\mathbf {r = 0.73, p < 0.001}$) and a moderate agreement for the second heart sound ($\mathbf {r = 0.56, p < 0.001}$). In conclusion, our work is the first to demonstrate that radar-based systems are feasible for contactless evaluation of heart sound propagation, offering new possibilities for research and health monitoring.


  • Open Access

    Systematic Investigation of Heart Sound Propagation using Continuous Wave Radar

    by Marie Oesten, Luca Abel, Nils C. Albrecht, Robert Richer, Dominik Langer, Stefan G. Griesshammer, Khalida Ghanem, Tobias Steigleder, Christoph Ostgathe, Alexander Koelpin, et al.

    Monitoring the propagation of mechanical cardiac signals throughout the body is crucial for assessing cardiovascular health. A common drawback of current gold standard methods for vital sign monitoring is the necessity for continuous skin contact. Radar-based sensing offers a promising alternative by enabling contactless measurement of cardiac activity, including heart sound signals. As previous research has primarily focused on deriving signals from proximal body regions, insights into heart sound propagation to peripheral areas are lacking. To address this, we systematically investigated whether radar-based heart sound detection and propagation measurement is feasible across the whole body. Using a custom-built continuous-wave radar system and phonocardiogram as reference, we simultaneously recorded heart sounds in N=22 participants sequentially at eleven locations. The electrocardiogram served as reference for electrical heart activity. After synchronization and preprocessing, we manually segmented the heart sounds and extracted temporal characteristics from ensemble-averaged signals. Our findings show that heart sounds can be detected across the entire body with the radar-based as well as the gold standard system. Furthermore, the heart sounds' temporal characteristics vary between measurement locations. As the distance to the heart increases, we observed significantly increased propagation time intervals. This finding is consistent across both systems, exhibiting a high agreement with a Pearson Correlation Coefficient of .71 for the first and .68 for the second heart sound. In conclusion, our work is the first to demonstrate that radar-based systems are feasible for contactless detection of heart sounds and evaluating their propagation, offering new possibilities for research and health monitoring.