JCJeremy Cramer

Jeremy Cramer

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jeremy Cramer has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Contrôle ultra rapide de température sur puce : PCR rapide et régulation du cycle cellulaire

    by Jérémy Cramer

    L'objet de cette thèse fut d'utiliser l'avantage qu'offre la microfluidique couplée à la thermique, pour fabriquer des dispositifs de contrôle de température sur des projets/applications distincts en vue de leur valorisation. En biologie moléculaire, par la réalisation d'une PCR quantitative rapide, pour la détection d'agents pathogènes. Nous avons réalisé une nouvelle plateforme de détection d'agent pathogène capable de faire 30 cycles d'amplifications en moins de trois minutes. Nous avons également illustré la capacité du dispositif à quantifier par fluorescence en temps réel des agents simulant de l'Anthrax et d'Ebola. 7 minutes et 7 minutes 30 secondes suffisent pour amplifier/détecter ces bactéries et virus. Nous avons également prouvé qu'à ces vitesses ce dispositif rapide de qPCR/RT-qPCR ne dégradait pas l'efficacité, la spécificité et les cycles seuils de détection. Nous avons également démontré que la sensibilité du dispositif était de 100 copies d'Adn initiale. En biologie cellulaire, Nous avons réalisé un dispositif " universel " de contrôle dynamique de température pour l'imagerie cellulaire haute résolution. Ce dispositif de contrôle dynamique de température, permet l'étude spatiotemporelle de mécanismes cellulaires sous microscope haute résolution grâce à l'utilisation de mutant thermosensibles. De nombreuses validations biologiques ont ainsi été réalisées sur notre dispositif dont l'objet final est la commercialisation.

  • Open Access

    Environmentally Controlled Microfluidic System Enabling Immune Cell Flow and Activation in an Endothelialised Skin‐On‐Chip

    by Elisabetta Michielon, Matteo Boninsegna, Taco Waaijman, Dario Fassini, Sander W. Spiekstra, Jeremy Cramer, Pierre Gaudriault, János Kodolányi, Tanja D. de Gruijl, Antoni Homs‐Corbera, et al.

    Integration of reconstructed human skin (RhS) into organ‐on‐chip (OoC) platforms addresses current limitations imposed by static culturing. This innovation, however, is not without challenges. Microfluidic devices, while powerful, often encounter usability, robustness, and gas bubble issues that hinder large‐scale high‐throughput setups. This study aims to develop a novel re‐usable multi‐well microfluidic adaptor (MMA) with the objective to provide a flexible tool for biologists implementing complex 3D biological models (e.g., skin) while enabling simultaneous user control over temperature, medium flow, oxigen (O2), nitrogen (N2), and carbon dioxide (CO2) without the need for an incubator. The presented MMA device is designed to be compatible with standard, commercially available 6‐well multi‐well plates (6MWPs) and 12‐well transwells. This MMA‐6MWP setup is employed to generate a skin‐on‐chip (SoC). RhS viability is maintained under flow for three days and their morphology closely resembles that of native human skin. A proof‐of‐concept study demonstrates the system's potential in toxicology applications by combining endothelialised RhS with flowing immune cells. This dynamic setting activates the monocyte‐like MUTZ‐3 cells (CD83 and CD86 upregulation) upon topical exposure of RhS to a sensitizer, revealing the MMA‐6MWP's unique capabilities compared to static culturing, where such activation is absent.


  • Open Access

    An easy-to-build and re-usable microfluidic system for live-cell imaging

    by Julien Babic, Laurent Griscom, Jeremy Cramer, Damien Coudreuse

    Real-time monitoring of cellular responses to dynamic changes in their environment or to specific treatments has become central to cell biology. However, when coupled to live-cell imaging, such strategies are difficult to implement with precision and high time resolution, and the simultaneous alteration of multiple parameters is a major challenge. Recently, microfluidics has provided powerful solutions for such analyses, bringing an unprecedented level of control over the conditions and the medium in which cells under microscopic observation are grown. However, such technologies have remained under-exploited, largely as a result of the complexity associated with microfabrication procedures. In this study, we have developed simple but powerful microfluidic devices dedicated to live-cell imaging. These microsystems take advantage of a robust elastomer that is readily available to researchers and that presents excellent bonding properties, in particular to microscopy-grade glass coverslips. Importantly, the chips are easy-to-build without sophisticated equipment, and they are compatible with the integration of complex, customized fluidic networks as well as with the multiplexing of independent assays on a single device. We show that the chips are re-usable, a significant advantage for the popularization of microfluidics in cell biology. Moreover, we demonstrate that they allow for the dynamic, accurate and simultaneous control of multiple parameters of the cellular environment. While they do not possess all the features of the microdevices that are built using complex and costly procedures, the simplicity and versatility of the chips that we have developed make them an attractive alternative for a range of applications. The emergence of such devices, which can be fabricated and used by any laboratory, will provide the possibility for a larger number of research teams to take full advantage of these new methods for investigating cell biology.


  • Ultrafast, sensitive and large-volume on-chip real-time PCR for the molecular diagnosis of bacterial and viral infections

    by Timothée Houssin, Jérémy Cramer, Rébecca Grojsman, Lyes Bellahsene, Guillaume Colas, Hélène Moulet, Walter Minnella, Christophe Pannetier, Maël Leberre, Adrien Plecis, et al.

    We present an ultra-fast microfluidic real-time PCR system enabling analysis in ≈7 minutes while conserving large volume and high efficiency/sensitivity.