Bartosz Kunka
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Bartosz Kunka has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Andrzej Czyżewski
Multimedia Systems, Gdańsk University of Technology, Gdansk, Poland, Poland
3 shared publications Agnieszka Kwiatkowska
Kazimierz Wielki Univ
2 shared publicationsAdam Korzeniewski
Multimedia Systems Dept
1 shared publication- Agata Goraczko
Department of Biostructure, Wroclaw University of Health and Sport Sciences, 51-612 Wroclaw, Poland
1 shared publication - Anna Stachowicz
Neurorehabilitation Clinic, 54-530 Wroclaw, Poland
1 shared publication - Bozena Kostek
Faculty of Electronics, Telecommunications and Informatics, Audio Acoustics Laboratory, Gdask University of Technology, Gdask, Poland
1 shared publication
Latest Publications
- Open Access
- 18 October 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (20) , 6227
Can Eye Tracking Help Assess the State of Consciousness in Non-Verbal Brain Injury Patients?
Background/Objectives: Developments in eye-tracking technology are opening up new possibilities for diagnosing patients in a state of minimal consciousness because they can provide information on visual behavior, and the movements of the eyeballs are correlated with the patients’ level of consciousness. The purpose of this study was to provide validation of a tool, based on eye tracking by comparing the results obtained with the assessment obtained using the Coma Recovery Scale-Revised (CRS-R). Methods: The mul-ti-center clinical trial was conducted in Poland in 2022–2023. The results of 46 patients who were not able to communicate verbally due to severe brain injury were analyzed in this study. The state of consciousness of patients was assessed using the Minimally Conscious State Detection test (MCSD), installed on an eye tracker and compared to CRS-R. The examinations consisted of performing the MCSD test on patients five times (T1–T5) within 14 days. Collected data were processed based on the FDA and GCP’s regulatory requirements. Depending on the nature of the data, the mean and standard deviation, median and lower and upper quartiles, and maximum and minimum values were calculated. Passing–Bablok regression analysis was used to assess the measurement equiva-lence of the methods used. Results: There was no difference between the MCSD and CRS-R in the raw change between T5 and T1 time points, as well as in the total % of points from all time points. The MCSD results from each time point show that at least the first two measurements serve to famil-iarize and adapt the patient to the measurement process, and the third and next measurement should be considered reliable. Conclusions: The results indicated a significant relationship be-tween the scores obtained with MCSD and CRS-R. The results suggest that it seems reasonable to introduce an assessment of the patient’s state of consciousness based on eye-tracking technology. The use of modern technology to assess a patient’s state of consciousness opens up the opportunity for greater objectivity, as well as a reduction in the workload of qualified personnel.
- 18 October 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (20) , 6227
Open AccessCan Eye Tracking Help Assess the State of Consciousness in Non-Verbal Brain Injury Patients?
Background/Objectives: Developments in eye-tracking technology are opening up new possibilities for diagnosing patients in a state of minimal consciousness because they can provide information on visual behavior, and the movements of the eyeballs are correlated with the patients’ level of consciousness. The purpose of this study was to provide validation of a tool, based on eye tracking by comparing the results obtained with the assessment obtained using the Coma Recovery Scale-Revised (CRS-R). Methods: The mul-ti-center clinical trial was conducted in Poland in 2022–2023. The results of 46 patients who were not able to communicate verbally due to severe brain injury were analyzed in this study. The state of consciousness of patients was assessed using the Minimally Conscious State Detection test (MCSD), installed on an eye tracker and compared to CRS-R. The examinations consisted of performing the MCSD test on patients five times (T1–T5) within 14 days. Collected data were processed based on the FDA and GCP’s regulatory requirements. Depending on the nature of the data, the mean and standard deviation, median and lower and upper quartiles, and maximum and minimum values were calculated. Passing–Bablok regression analysis was used to assess the measurement equiva-lence of the methods used. Results: There was no difference between the MCSD and CRS-R in the raw change between T5 and T1 time points, as well as in the total % of points from all time points. The MCSD results from each time point show that at least the first two measurements serve to famil-iarize and adapt the patient to the measurement process, and the third and next measurement should be considered reliable. Conclusions: The results indicated a significant relationship be-tween the scores obtained with MCSD and CRS-R. The results suggest that it seems reasonable to introduce an assessment of the patient’s state of consciousness based on eye-tracking technology. The use of modern technology to assess a patient’s state of consciousness opens up the opportunity for greater objectivity, as well as a reduction in the workload of qualified personnel.
- 1 January 2014
- Published by Springer Nature in Lecture Notes in Computer Science
- p. 432-441
Eye-Gaze Tracking-Based Telepresence System for Videoconferencing
- 1 January 2014
- Published by Springer Nature in Lecture Notes in Computer Science
- p. 432-441
Eye-Gaze Tracking-Based Telepresence System for Videoconferencing
- 1 January 2014
- Published by Springer Nature
- p. 57-67
Consciousness Study of Subjects with Unresponsive Wakefulness Syndrome Employing Multimodal Interfaces
- 1 January 2014
- Published by Springer Nature
- p. 57-67
Consciousness Study of Subjects with Unresponsive Wakefulness Syndrome Employing Multimodal Interfaces
- 1 April 2012
- Published by World Scientific Pub Co Pte Ltd in International Journal on Artificial Intelligence Tools
- Vol. 21 (02)
AWARENESS EVALUATION OF PATIENTS IN VEGETATIVE STATE EMPLOYING EYE-GAZE TRACKING SYSTEM
Application of eye-gaze tracking system to awareness evaluation is demonstrated. Hitherto awareness evaluation methods are presented. The assumptions of proposed method based on analysis of visual activity of patients in vegetative state are demonstrated. The eye-gaze tracking system "Cyber-Eye" developed at the Multimedia Systems Department employed to conducted experiments is presented. Research described in the paper indicates that awareness level of 13 of 15 tested patients was misdiagnosed before the new method of awareness evaluation is introduced.
- 1 April 2012
- Published by World Scientific Pub Co Pte Ltd in International Journal on Artificial Intelligence Tools
- Vol. 21 (02)
AWARENESS EVALUATION OF PATIENTS IN VEGETATIVE STATE EMPLOYING EYE-GAZE TRACKING SYSTEM
Application of eye-gaze tracking system to awareness evaluation is demonstrated. Hitherto awareness evaluation methods are presented. The assumptions of proposed method based on analysis of visual activity of patients in vegetative state are demonstrated. The eye-gaze tracking system "Cyber-Eye" developed at the Multimedia Systems Department employed to conducted experiments is presented. Research described in the paper indicates that awareness level of 13 of 15 tested patients was misdiagnosed before the new method of awareness evaluation is introduced.