Liam Swanson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Liam Swanson has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Abdulaziz Alosaimi
Labatt Family Heart Centre, Division of Cardiology, The Hospital for Sick Children, Toronto, ON M5G 1X8, Canada
1 shared publication - Alistair Revell
The University of Manchester
1 shared publication - Amin Deyranlou
Department of Mechanical Engineering, Ferdowsi University of Mashhad, Mashhad, Iran
1 shared publication - Amir Keshmiri
School of Engineering, University of Manchester, Manchester, UK
1 shared publication - Andrew C. Cook
Institute of Cardiovascular Science, University College London, London, UK
1 shared publication Barend Fourie
Department of Mechanical Engineering, University of Cape Town, Cape Town, South Africa
1 shared publication
Latest Publications
- Open Access
- 17 October 2024
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 11 (10) , 330
A 3D Statistical Shape Model of the Right Ventricular Outflow Tract in Pulmonary Valve Replacement Patients Post-Surgical Repair
Assessment of the right ventricular outflow tract and pulmonary arteries (RVOT) for percutaneous pulmonary valve implantation (PPVI) uses discrete measurements (diameters and lengths) from medical images. This multi-centre study identified the 3D RVOT shape features prevalent in patients late after surgical repair of congenital heart disease (CHD). A 3D RVOT statistical shape model (SSM) was computed from 81 retrospectively selected CHD patients (14.7 ± 6.8 years) who required pulmonary valve replacement late after surgical repair. A principal component analysis identified prevalent shape features (modes) within the population which were compared with standard geometric measurements (diameter, length and surface area) and between sub-groups of diagnosis, RVOT type and dysfunction. Shape mode 1 and 2 represented RVOT size and curvature and tapering and length, respectively. Shape modes 3–5 related to branch pulmonary artery calibre, conical vs. bulbous RVOTs and RVOT curvature, respectively. Tetralogy of Fallot, transannular patch type and regurgitant RVOTs were larger and straighter while conduit and stenotic types were longer and more cylindrical than other subgroups. This SSM analysed the main 3D shape features present in a population of RVOTs, exploiting the wide 3D anatomical information provided by routine imaging. This morphological information may have implications for PPVI patient selection and device design.
- 17 October 2024
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 11 (10) , 330
Open AccessA 3D Statistical Shape Model of the Right Ventricular Outflow Tract in Pulmonary Valve Replacement Patients Post-Surgical Repair
Assessment of the right ventricular outflow tract and pulmonary arteries (RVOT) for percutaneous pulmonary valve implantation (PPVI) uses discrete measurements (diameters and lengths) from medical images. This multi-centre study identified the 3D RVOT shape features prevalent in patients late after surgical repair of congenital heart disease (CHD). A 3D RVOT statistical shape model (SSM) was computed from 81 retrospectively selected CHD patients (14.7 ± 6.8 years) who required pulmonary valve replacement late after surgical repair. A principal component analysis identified prevalent shape features (modes) within the population which were compared with standard geometric measurements (diameter, length and surface area) and between sub-groups of diagnosis, RVOT type and dysfunction. Shape mode 1 and 2 represented RVOT size and curvature and tapering and length, respectively. Shape modes 3–5 related to branch pulmonary artery calibre, conical vs. bulbous RVOTs and RVOT curvature, respectively. Tetralogy of Fallot, transannular patch type and regurgitant RVOTs were larger and straighter while conduit and stenotic types were longer and more cylindrical than other subgroups. This SSM analysed the main 3D shape features present in a population of RVOTs, exploiting the wide 3D anatomical information provided by routine imaging. This morphological information may have implications for PPVI patient selection and device design.
- Open Access
- 3 June 2020
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 8, 409
A Patient-Specific CFD Pipeline Using Doppler Echocardiography for Application in Coarctation of the Aorta in a Limited Resource Clinical Context
Congenital heart disease (CHD) is the most common birth defect globally and coarctation of the aorta (CoA) is one of the commoner CHD conditions, affecting around 1/1800 live births. CoA is considered a CHD of critical severity. Unfortunately, the prognosis for a child born in a low and lower-middle income country (LLMICs) with CoA is far worse than in a high-income country. Reduced diagnostic and interventional capacities of specialists in these regions leads to delayed diagnosis and treatment, which in turn leads to more cases presenting at an advanced stage. Computational fluid dynamics (CFD) is an important tool in this context since it can provide additional diagnostic data in the form of haemodynamic parameters. It also provides an in-silico framework, both to test potential procedures and to assess the risk of further complications arising post-repair. Although this concept is already in practice in high income countries, the clinical infrastructure in LLMICs can be sparse, and access to advanced imaging modalities such as phase contrast magnetic resonance imaging (PC-MRI) is limited, if not impossible. In this study, a pipeline was developed in conjunction with clinicians at the Red Cross War Memorial Children’s Hospital, Cape Town and was applied to perform a patient-specific CFD study of CoA. The pipeline uses data acquired from CT angiography and Doppler transthoracic echocardiography (both much more clinically available than MRI in LLMICs), while segmentation is conducted via SimVascular and simulation is realized using OpenFOAM. The reduction in cost through use of open-source software and the use of broadly available imaging modalities makes the methodology clinically feasible and repeatable within resource constrained environments. The project identifies the key role of Doppler echocardiography, despite its disadvantages, as an intrinsic component of the pipeline if it is to be used routinely in LLMICs.
- 3 June 2020
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 8, 409
Open AccessA Patient-Specific CFD Pipeline Using Doppler Echocardiography for Application in Coarctation of the Aorta in a Limited Resource Clinical Context
Congenital heart disease (CHD) is the most common birth defect globally and coarctation of the aorta (CoA) is one of the commoner CHD conditions, affecting around 1/1800 live births. CoA is considered a CHD of critical severity. Unfortunately, the prognosis for a child born in a low and lower-middle income country (LLMICs) with CoA is far worse than in a high-income country. Reduced diagnostic and interventional capacities of specialists in these regions leads to delayed diagnosis and treatment, which in turn leads to more cases presenting at an advanced stage. Computational fluid dynamics (CFD) is an important tool in this context since it can provide additional diagnostic data in the form of haemodynamic parameters. It also provides an in-silico framework, both to test potential procedures and to assess the risk of further complications arising post-repair. Although this concept is already in practice in high income countries, the clinical infrastructure in LLMICs can be sparse, and access to advanced imaging modalities such as phase contrast magnetic resonance imaging (PC-MRI) is limited, if not impossible. In this study, a pipeline was developed in conjunction with clinicians at the Red Cross War Memorial Children’s Hospital, Cape Town and was applied to perform a patient-specific CFD study of CoA. The pipeline uses data acquired from CT angiography and Doppler transthoracic echocardiography (both much more clinically available than MRI in LLMICs), while segmentation is conducted via SimVascular and simulation is realized using OpenFOAM. The reduction in cost through use of open-source software and the use of broadly available imaging modalities makes the methodology clinically feasible and repeatable within resource constrained environments. The project identifies the key role of Doppler echocardiography, despite its disadvantages, as an intrinsic component of the pipeline if it is to be used routinely in LLMICs.