Leshan Qiu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Leshan Qiu has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Yun Bai
Institute of Microelectronics, Chinese Academy of Sciences
10 shared publications - Xinyu Liu
Chinese Academy of Sciences
8 shared publications - Xiaoli Tian
Chinese Academy of Sciences
7 shared publications - Yidan Tang
Chinese Academy of Sciences Institute of Microelectronics
7 shared publications Jieqin Ding
State Key Laboratory of Advanced Power Semiconductor Device, Zhuzhou CRRC Times Semiconductor Company Ltd., Zhuzhou, China
6 shared publications- Jilong Hao
Institute of Microelectronics of the Chinese Academy of Sciences
4 shared publications
Latest Publications
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 73 (10) , 5928-5935
Investigation of Single-Event Effects in SiC LDMOS Induced by Heavy-Ion Irradiation
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 73 (10) , 5928-5935
Investigation of Single-Event Effects in SiC LDMOS Induced by Heavy-Ion Irradiation
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 73 (3) , 1142-1148
Heavy-Ion-Induced Gate–Source Damage at High Drain Bias in SiC Power MOSFET
The surface-level gate-to-source damage mechanism in silicon carbide (SiC) power metal– oxide–semiconductor field-effect transistors (MOSFETs) is investigated under heavy-ion irradiation at high drain bias conditions (about 50% of the breakdown voltage). Unlike conventional single-event burnout (SEB)-induced big void formation, the observed damage is confined to a single cell and becomes detectable only under gate bias. Cross-sectional analysis shows that the affected region includes the polysilicon gate, the gate oxide layer, the interlayer dielectric (ILD), the source metal, and the underlying SiC surface. Electrothermal simulations confirm that surface degradation is initiated by catastrophic gate oxide breakdown, followed by redistribution of the leakage current and localized thermal accumulation.
- 12 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 73 (3) , 1142-1148
Heavy-Ion-Induced Gate–Source Damage at High Drain Bias in SiC Power MOSFET
The surface-level gate-to-source damage mechanism in silicon carbide (SiC) power metal– oxide–semiconductor field-effect transistors (MOSFETs) is investigated under heavy-ion irradiation at high drain bias conditions (about 50% of the breakdown voltage). Unlike conventional single-event burnout (SEB)-induced big void formation, the observed damage is confined to a single cell and becomes detectable only under gate bias. Cross-sectional analysis shows that the affected region includes the polysilicon gate, the gate oxide layer, the interlayer dielectric (ILD), the source metal, and the underlying SiC surface. Electrothermal simulations confirm that surface degradation is initiated by catastrophic gate oxide breakdown, followed by redistribution of the leakage current and localized thermal accumulation.
- 23 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Device and Materials Reliability
- Vol. 25 (4) , 959-965
SiC Damage Induced by Heavy Ion Irradiation and Post-Gate Stress in SiC MOSFETs
This study provides a detailed investigation of the anomalous SiC damage morphology and associated failure mechanisms in SiC MOSFETs. The devices were irradiated with Tantalum (Ta) ions at a linear energy transfer (LET) value of 80.7 MeV∙cm/mg under a drain bias of 80 V. Following irradiation, the post irradiation gate stress (PIGS) test was performed to trigger oxide breakdown and the adjacent SiC damage. Distinctive SiC damage characteristics are identified through failure techniques, including a semicircular anomalous surface damage zone connecting an elongated bulk damage trace. Additionally, a localized crystal arrangement region is also detected in the upper of the damage trace. Further analysis reveals that the anomalous damage morphology results from synergistic interaction between initial ion strikes and subsequent PIGS test. The effects of ion strikes and the subsequent SiC structural disruption processes during PIGS test are further discussed. This experimental finding contributes to a more comprehensive understanding of the damage mechanism in SiC MOSFETs exposed to irradiation and electrical stress.
- 23 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Device and Materials Reliability
- Vol. 25 (4) , 959-965
SiC Damage Induced by Heavy Ion Irradiation and Post-Gate Stress in SiC MOSFETs
This study provides a detailed investigation of the anomalous SiC damage morphology and associated failure mechanisms in SiC MOSFETs. The devices were irradiated with Tantalum (Ta) ions at a linear energy transfer (LET) value of 80.7 MeV∙cm/mg under a drain bias of 80 V. Following irradiation, the post irradiation gate stress (PIGS) test was performed to trigger oxide breakdown and the adjacent SiC damage. Distinctive SiC damage characteristics are identified through failure techniques, including a semicircular anomalous surface damage zone connecting an elongated bulk damage trace. Additionally, a localized crystal arrangement region is also detected in the upper of the damage trace. Further analysis reveals that the anomalous damage morphology results from synergistic interaction between initial ion strikes and subsequent PIGS test. The effects of ion strikes and the subsequent SiC structural disruption processes during PIGS test are further discussed. This experimental finding contributes to a more comprehensive understanding of the damage mechanism in SiC MOSFETs exposed to irradiation and electrical stress.
- 29 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 72 (11) , 5913-5918
Thermal Dynamic of Single-Event Burnout in SiC Power MOSFETs
Single-event burnout (SEB) poses a significant threat to silicon carbide (SiC) MOSFETs when operating in aerospace environments, resulting in permanent functional failures of the device and system-level risks through ion-induced thermal runaway effects. However, the detailed thermal response process and triggering mechanism remain inadequately understood. In this study, a novel current-limiting method was used to investigate the SEB damage evolution process and mechanism in SiC MOSFETs. Experimental results show that the SEB events can be divided into three distinct stages: initial damage at the p-n-junction, followed by a shift to the source metal/SiC corner, where lattice eutectic triggers intensified p-n-junction degradation, and final burnout when the n-n-junction reaches SiC sublimation temperature. Subsequent simulation results show that the current crowding effect at the SiC surface and avalanche breakdown at the n-n-junction are critical contributors to the SEB process. The findings provide useful insights into understanding the ion-induced catastrophic phenomena in SiC power devices.
- 29 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 72 (11) , 5913-5918
Thermal Dynamic of Single-Event Burnout in SiC Power MOSFETs
Single-event burnout (SEB) poses a significant threat to silicon carbide (SiC) MOSFETs when operating in aerospace environments, resulting in permanent functional failures of the device and system-level risks through ion-induced thermal runaway effects. However, the detailed thermal response process and triggering mechanism remain inadequately understood. In this study, a novel current-limiting method was used to investigate the SEB damage evolution process and mechanism in SiC MOSFETs. Experimental results show that the SEB events can be divided into three distinct stages: initial damage at the p-n-junction, followed by a shift to the source metal/SiC corner, where lattice eutectic triggers intensified p-n-junction degradation, and final burnout when the n-n-junction reaches SiC sublimation temperature. Subsequent simulation results show that the current crowding effect at the SiC surface and avalanche breakdown at the n-n-junction are critical contributors to the SEB process. The findings provide useful insights into understanding the ion-induced catastrophic phenomena in SiC power devices.
- 1 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 72 (5) , 2233-2239
Microstructure Damage for Single-Event Leakage Current II in SiC MOSFETs Induced by Heavy Ion
This article investigates the electrical characteristics and microstructure damage associated with single-event leakage current II (SELC II) degradation in silicon carbide (SiC) MOSFETs$\vphantom{\sum^{\int}}$ subjected to 181Ta heavy-ion irradiation. For 1200-V SiC MOSFETs, SELC II degradation was observed at drain biases between 450 and 600 V. Postirradiation, two distinct leakage current paths were identified in SiC MOSFETs affected by SELC II degradation when a drain bias was applied. The drain–source leakage path, which operates independent of gate oxide damage, appeared only after a specific voltage threshold was surpassed. Similar electrical behavior observed in both irradiated and postirradiated SiC MOSFETs and p-i-n diodes indicates that the p-n junction plays a key role in the SELC II degradation of SiC MOSFETs. High-resolution TEM analysis also reveals that, for the first time, SELC II-induced microstructural damage, including cavities, dislocations, and misorientations, concentrated at the interface between the P-well region and the N-epilayer in SiC MOSFETs.
- 1 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 72 (5) , 2233-2239
Microstructure Damage for Single-Event Leakage Current II in SiC MOSFETs Induced by Heavy Ion
This article investigates the electrical characteristics and microstructure damage associated with single-event leakage current II (SELC II) degradation in silicon carbide (SiC) MOSFETs$\vphantom{\sum^{\int}}$ subjected to 181Ta heavy-ion irradiation. For 1200-V SiC MOSFETs, SELC II degradation was observed at drain biases between 450 and 600 V. Postirradiation, two distinct leakage current paths were identified in SiC MOSFETs affected by SELC II degradation when a drain bias was applied. The drain–source leakage path, which operates independent of gate oxide damage, appeared only after a specific voltage threshold was surpassed. Similar electrical behavior observed in both irradiated and postirradiated SiC MOSFETs and p-i-n diodes indicates that the p-n junction plays a key role in the SELC II degradation of SiC MOSFETs. High-resolution TEM analysis also reveals that, for the first time, SELC II-induced microstructural damage, including cavities, dislocations, and misorientations, concentrated at the interface between the P-well region and the N-epilayer in SiC MOSFETs.
- 11 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 72 (3) , 1053-1059
Effect of Split-Gate Structure in SiC MOSFET on Single-Event Gate Oxide Damage
This study designed a type of silicon carbide (SiC) split-gate MOSFETs (SG-MOSFETs) to evaluate the effect of SG structure on single-event gate oxide damage under heavy-ion irradiation. Comparisons with conventional MOSFETs (C-MOSFETs) by krypton (84Kr+18) ion irradiation experiments showed that SG-MOSFETs exhibited no significant improvement in single-event leakage current (SELC) degradation. However, following irradiation at a drain bias of 100 V, the gate bias at which the SG-MOSFET reached the current limit during postirradiation gate stress (PIGS) tests increased by approximately 60%, indicating SG-MOSFETs enhanced their irradiation reliability at low drain bias. In C-MOSFETs, the damage was located above the center of the JFET region within the active region. In contrast, in SG-MOSFETs, the damage was observed at the corner of the polysilicon gate in the main junction region. This shift in the damage location suggests that the SG structure moves the most sensitive point from the center of the JFET region to other areas. However, structure deviations during the manufacturing of the SG may introduce new sensitivities. Therefore, further design optimization is needed to improve irradiation survivability at higher drain biases.
- 11 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 72 (3) , 1053-1059
Effect of Split-Gate Structure in SiC MOSFET on Single-Event Gate Oxide Damage
This study designed a type of silicon carbide (SiC) split-gate MOSFETs (SG-MOSFETs) to evaluate the effect of SG structure on single-event gate oxide damage under heavy-ion irradiation. Comparisons with conventional MOSFETs (C-MOSFETs) by krypton (84Kr+18) ion irradiation experiments showed that SG-MOSFETs exhibited no significant improvement in single-event leakage current (SELC) degradation. However, following irradiation at a drain bias of 100 V, the gate bias at which the SG-MOSFET reached the current limit during postirradiation gate stress (PIGS) tests increased by approximately 60%, indicating SG-MOSFETs enhanced their irradiation reliability at low drain bias. In C-MOSFETs, the damage was located above the center of the JFET region within the active region. In contrast, in SG-MOSFETs, the damage was observed at the corner of the polysilicon gate in the main junction region. This shift in the damage location suggests that the SG structure moves the most sensitive point from the center of the JFET region to other areas. However, structure deviations during the manufacturing of the SG may introduce new sensitivities. Therefore, further design optimization is needed to improve irradiation survivability at higher drain biases.
- 6 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (8) , 2340-2348
Analysis of SiC Damage Associated With Single-Event Gate Oxide Damage
This paper presents observations of SiC damage related to single-event gate oxide damage in SiC MOSFETs subjected to varying drain biases following heavy-ion irradiation and electrical stress. At low and medium drain biases, both surface melted and lattice damages in SiC were detected by transmission electron microscopy (TEM). While at high drain bias, crack damage propagation into the epilayer was observed directly by Scanning electron microscopy (SEM). Despite the differing types of observed SiC damage, all were confined beneath the gate oxide damage or latent damage induced by heavy ion strikes. Numerical simulations indicate that after gate oxide rupture, the formation of a gate-drain leakage path increases the current beneath the damaged oxide, leading to localized heating and subsequent SiC degradation and damage. These findings provide valuable insights for understanding the failure mechanisms of SiC MOSFETs subjected to single-event failures.
- 6 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 72 (8) , 2340-2348
Analysis of SiC Damage Associated With Single-Event Gate Oxide Damage
This paper presents observations of SiC damage related to single-event gate oxide damage in SiC MOSFETs subjected to varying drain biases following heavy-ion irradiation and electrical stress. At low and medium drain biases, both surface melted and lattice damages in SiC were detected by transmission electron microscopy (TEM). While at high drain bias, crack damage propagation into the epilayer was observed directly by Scanning electron microscopy (SEM). Despite the differing types of observed SiC damage, all were confined beneath the gate oxide damage or latent damage induced by heavy ion strikes. Numerical simulations indicate that after gate oxide rupture, the formation of a gate-drain leakage path increases the current beneath the damaged oxide, leading to localized heating and subsequent SiC degradation and damage. These findings provide valuable insights for understanding the failure mechanisms of SiC MOSFETs subjected to single-event failures.
- 9 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 72 (1) , 323-330
A Study on Short Circuit Characteristics of 4H-SiC MOSFET Coupled With Electron Irradiation
In this article, the electron irradiation coupling short circuit (SC) characteristics of 4H-silicon carbide (SiC) MOSFET are studied. The SC influence mechanism of electron irradiation coupling is proposed, and the influence of minority carrier lifetime on the SC characteristics of the device after irradiation is further studied. The 4H-SiC MOSFET and 4H-SiC wafer are irradiated by 2-MeV electrons. The changes in static parameters of 4H-SiC MOSFET are analyzed, and the SC characteristics of 4H-SiC MOSFET under electron irradiation coupling are studied by the limit SC (LSC) test method. The results show that after irradiation, the SC peak current of 4H-SiC MOSFET increases by 9.6%, the critical SC failure time ( $\textit{t}_{\text{crit}}$ ) decreases by 10.85%, and the critical SC failure energy ( $\textit{E}_{\text{crit}}$ ) decreases by 5.29%. MOSFET’s LSC failure mechanism after electron irradiation is parasitic BJT conduction. Through TCAD simulation and theoretical derivation, it is proved that the increase of the base current is the main cause of parasitic BJT conduction, and the decrease of carrier lifetime will trigger parasitic BJT conduction earlier. The minority carrier lifetime can be reduced by 97% after electron irradiation. The influence mechanism of electron irradiation on SC characteristics is verified by TCAD simulation. The total ion dose effect will increase the SC peak current, and the displacement effect will significantly reduce the minority carrier lifetime, thus reducing the SC capacity of the device. The simulation results are consistent with the experimental results.
- 9 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 72 (1) , 323-330
A Study on Short Circuit Characteristics of 4H-SiC MOSFET Coupled With Electron Irradiation
In this article, the electron irradiation coupling short circuit (SC) characteristics of 4H-silicon carbide (SiC) MOSFET are studied. The SC influence mechanism of electron irradiation coupling is proposed, and the influence of minority carrier lifetime on the SC characteristics of the device after irradiation is further studied. The 4H-SiC MOSFET and 4H-SiC wafer are irradiated by 2-MeV electrons. The changes in static parameters of 4H-SiC MOSFET are analyzed, and the SC characteristics of 4H-SiC MOSFET under electron irradiation coupling are studied by the limit SC (LSC) test method. The results show that after irradiation, the SC peak current of 4H-SiC MOSFET increases by 9.6%, the critical SC failure time ( $\textit{t}_{\text{crit}}$ ) decreases by 10.85%, and the critical SC failure energy ( $\textit{E}_{\text{crit}}$ ) decreases by 5.29%. MOSFET’s LSC failure mechanism after electron irradiation is parasitic BJT conduction. Through TCAD simulation and theoretical derivation, it is proved that the increase of the base current is the main cause of parasitic BJT conduction, and the decrease of carrier lifetime will trigger parasitic BJT conduction earlier. The minority carrier lifetime can be reduced by 97% after electron irradiation. The influence mechanism of electron irradiation on SC characteristics is verified by TCAD simulation. The total ion dose effect will increase the SC peak current, and the displacement effect will significantly reduce the minority carrier lifetime, thus reducing the SC capacity of the device. The simulation results are consistent with the experimental results.
- 24 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electron Device Letters
- Vol. 45 (12) , 2319-2322
Gate Length Dependence of Bias Temperature Instabilities up to 400 °C in 4H-SiC CMOS Devices
This letter reports the bias temperature instabilities (BTI) of 4H-SiC CMOS devices with different gate lengths ( L ) and gate widths ( W ) for integrated circuits at 400 °C for the first time. The result shows that the threshold voltage shift of p-channel MOSFETs is significantly higher than that of n-channel MOSFETs. More serious BTI degradation is observed in CMOS devices with shorter L , especially for p-channel MOSFETs. Additionally, higher gate leakage current density and charged interface traps density are also found in fresh devices with shorter L . Through the energy-band structure, the physical cause of difference in transistor sizes originates from the inhomogeneous channel carrier concentration and charged interface traps density caused by the source and drain diffusion regions.
- 24 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electron Device Letters
- Vol. 45 (12) , 2319-2322
Gate Length Dependence of Bias Temperature Instabilities up to 400 °C in 4H-SiC CMOS Devices
This letter reports the bias temperature instabilities (BTI) of 4H-SiC CMOS devices with different gate lengths ( L ) and gate widths ( W ) for integrated circuits at 400 °C for the first time. The result shows that the threshold voltage shift of p-channel MOSFETs is significantly higher than that of n-channel MOSFETs. More serious BTI degradation is observed in CMOS devices with shorter L , especially for p-channel MOSFETs. Additionally, higher gate leakage current density and charged interface traps density are also found in fresh devices with shorter L . Through the energy-band structure, the physical cause of difference in transistor sizes originates from the inhomogeneous channel carrier concentration and charged interface traps density caused by the source and drain diffusion regions.
- 16 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (11) , 2377-2385
Degradation Under Low Drain Bias Induced by Heavy Ion in SiC MOSFETs
The safe operating area (SOA) for the drain bias of SiC MOSFETs in space applications has been limited due to the single-event effects (SEEs) induced by heavy ion irradiation. At a drain bias lower than 5% of the rated voltage, SiC MOSFETs are typically considered to be in the charge collection region, which usually does not cause destructive damage. However, in this article, the degradation induced by heavy ions at drain biases below 50 V for 1200 V SiC MOSFETs has been observed. During irradiation, the drain leakage current ( I DSS ) continuously increased with the accumulated dose. Meanwhile, the I DSS degradation showed a correlation between the drain bias and the cell topology of SiC MOSFETs. After irradiation, unacceptable I DSS degradation was still observed, but it recovered by about 40% after a month of room-temperature annealing. The I DSS also returned to its pre-irradiation level under negative gate bias, suggesting that the increase in I DSS could be associated with a leakage current path through the channel region, resulting from defects within the oxide or at the SiO 2 /SiC interface, likely introduced by the microdose effect. The gate leakage current ( I GSS ) was tested within the temperature range of 25 to 250 °C to investigate the temperature impact for gate oxide latent damage activation. As the drain bias increased during irradiation, the I GSS also increased significantly at higher temperatures, suggesting that latent damage within the gate oxide had been formed during irradiation.
- 16 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 71 (11) , 2377-2385
Degradation Under Low Drain Bias Induced by Heavy Ion in SiC MOSFETs
The safe operating area (SOA) for the drain bias of SiC MOSFETs in space applications has been limited due to the single-event effects (SEEs) induced by heavy ion irradiation. At a drain bias lower than 5% of the rated voltage, SiC MOSFETs are typically considered to be in the charge collection region, which usually does not cause destructive damage. However, in this article, the degradation induced by heavy ions at drain biases below 50 V for 1200 V SiC MOSFETs has been observed. During irradiation, the drain leakage current ( I DSS ) continuously increased with the accumulated dose. Meanwhile, the I DSS degradation showed a correlation between the drain bias and the cell topology of SiC MOSFETs. After irradiation, unacceptable I DSS degradation was still observed, but it recovered by about 40% after a month of room-temperature annealing. The I DSS also returned to its pre-irradiation level under negative gate bias, suggesting that the increase in I DSS could be associated with a leakage current path through the channel region, resulting from defects within the oxide or at the SiO 2 /SiC interface, likely introduced by the microdose effect. The gate leakage current ( I GSS ) was tested within the temperature range of 25 to 250 °C to investigate the temperature impact for gate oxide latent damage activation. As the drain bias increased during irradiation, the I GSS also increased significantly at higher temperatures, suggesting that latent damage within the gate oxide had been formed during irradiation.