Omidreza Heydari Tafreshi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Omidreza Heydari Tafreshi has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Ehsan Hajipour
Center of Excellence in Power System Management and Control, Department of Electrical Engineering, Sharif University of Technology, Tehran, Iran
2 shared publications - Mehran Hajiaghapour-Moghimi
Department of Electrical Engineering, Sharif University of Technology, Tehran, Iran
2 shared publications - Matti Lehtonen
School of Electrical Engineering, Aalto University, 02150 Espoo, Finland
1 shared publication - Mehdi Vakilian
Sharif University of Technology
1 shared publication
Latest Publications
- 29 August 2025
- Published by Elsevier in Electric Power Systems Research
- Vol. 250
Utilization of cryptocurrency mining load as high flexible load in virtual power plant
- 29 August 2025
- Published by Elsevier in Electric Power Systems Research
- Vol. 250
Utilization of cryptocurrency mining load as high flexible load in virtual power plant
- Open Access
- 16 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 153643-153663
Investigating the Cryptocurrency Mining Loads’ High Penetration Impact on Electric Power Grid
Cryptocurrency has become a pivotal player in global financial transactions due to its decentralized mining process, which eliminates the need for intermediaries. However, the operation of cryptocurrency mining devices (CMDs) requires significant electrical power, leading to an increase in network-connected cryptocurrency mining loads (CMLs) that pose challenges for power grid operators. This paper evaluates the integration of CMLs into power grids, focusing on distribution network performance. A technology-accepted model for assessing cryptocurrency mining performance is presented, along with an analysis of the impacts of high CML penetration on power grid planning and operation. Findings reveal that high CML penetration can complicate load forecasting, congest transmission lines, and increase the coincident peak load in distribution networks. A case study of Iran’s power network indicates that CMLs account for approximately 2.8% of the nation’s electricity consumption. Furthermore, if 5% of residential customers in Tehran install CMDs, the average coincident peak demand for this group rises by 26.81%. Additionally, the average power factor of a sample CMD is about 0.99, while total current distortion and third harmonic current exceed permissible limits, indicating potential power quality issues. This study highlights the challenges posed by CMLs and proposes strategies for their sustainable integration into power grids.
- 16 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 153643-153663
Open AccessInvestigating the Cryptocurrency Mining Loads’ High Penetration Impact on Electric Power Grid
Cryptocurrency has become a pivotal player in global financial transactions due to its decentralized mining process, which eliminates the need for intermediaries. However, the operation of cryptocurrency mining devices (CMDs) requires significant electrical power, leading to an increase in network-connected cryptocurrency mining loads (CMLs) that pose challenges for power grid operators. This paper evaluates the integration of CMLs into power grids, focusing on distribution network performance. A technology-accepted model for assessing cryptocurrency mining performance is presented, along with an analysis of the impacts of high CML penetration on power grid planning and operation. Findings reveal that high CML penetration can complicate load forecasting, congest transmission lines, and increase the coincident peak load in distribution networks. A case study of Iran’s power network indicates that CMLs account for approximately 2.8% of the nation’s electricity consumption. Furthermore, if 5% of residential customers in Tehran install CMDs, the average coincident peak demand for this group rises by 26.81%. Additionally, the average power factor of a sample CMD is about 0.99, while total current distortion and third harmonic current exceed permissible limits, indicating potential power quality issues. This study highlights the challenges posed by CMLs and proposes strategies for their sustainable integration into power grids.