Benjamin Orkild
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Benjamin Orkild has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Alan Morris
Department of Human Biology, University of Cape Town, Cape Town, South Africa
2 shared publications - Brian Zenger
Department of Medicine - Cardiovascular Division, Washington University in St. Louis School of Medicine, Saint Louis, MO, United States of America
2 shared publications - Eugene Kwan
Nora Eccles Harrison Cardiovascular Research and Training Institute, University of Utah , 95 S 2000 E, Bldg. 500, Salt Lake City, UT 84112, USA
2 shared publications - Karthik Karanth
School of Computing University of Utah Salt Lake City UT USA
2 shared publications - Krithika Iyer
University of Utah
2 shared publications - Ravi Ranjan
Department of Biomedical Engineering University of Utah Salt Lake City Utah USA
2 shared publications
Latest Publications
- 21 December 2024
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 68 (3) , 667-679
Image quality assessment and automation in late gadolinium-enhanced MRI of the left atrium in atrial fibrillation patients
Background Late gadolinium-enhanced (LGE) MRI has become a widely used technique to non-invasively image the left atrium prior to catheter ablation. However, LGE-MRI images are prone to variable image quality, with quality metrics that do not necessarily correlate to the image’s diagnostic quality. In this study, we aimed to define consistent clinically relevant metrics for image and diagnostic quality in 3D LGE-MRI images of the left atrium, have multiple observers assess LGE-MRI image quality to identify key features that measure quality and intra/inter-observer variabilities, and train and test a CNN to assess image quality automatically. Methods We identified four image quality categories that impact fibrosis assessment in LGE-MRI images and trained individuals to score 50 consecutive pre-ablation atrial fibrillation LGE-MRI scans from the University of Utah hospital image database. The trained individuals then scored 146 additional scans, which were used to train a convolutional neural network (CNN) to assess diagnostic quality. Results There was excellent agreement among trained observers when scoring LGE-MRI scans, with inter-rater reliability scores ranging from 0.65 to 0.76 for each category. When the quality scores were converted to a binary diagnostic/non-diagnostic, the CNN achieved a sensitivity of \(0.80 \pm 0.06\) and a specificity of \(0.56 \pm 0.10\). Conclusion The use of a training document with reference examples helped raters achieve excellent agreement in their quality scores. The CNN gave a reasonably accurate classification of diagnostic or non-diagnostic 3D LGE-MRI images of the left atrium, despite the use of a relatively small training set.- 21 December 2024
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 68 (3) , 667-679
Image quality assessment and automation in late gadolinium-enhanced MRI of the left atrium in atrial fibrillation patients
Background Late gadolinium-enhanced (LGE) MRI has become a widely used technique to non-invasively image the left atrium prior to catheter ablation. However, LGE-MRI images are prone to variable image quality, with quality metrics that do not necessarily correlate to the image’s diagnostic quality. In this study, we aimed to define consistent clinically relevant metrics for image and diagnostic quality in 3D LGE-MRI images of the left atrium, have multiple observers assess LGE-MRI image quality to identify key features that measure quality and intra/inter-observer variabilities, and train and test a CNN to assess image quality automatically. Methods We identified four image quality categories that impact fibrosis assessment in LGE-MRI images and trained individuals to score 50 consecutive pre-ablation atrial fibrillation LGE-MRI scans from the University of Utah hospital image database. The trained individuals then scored 146 additional scans, which were used to train a convolutional neural network (CNN) to assess diagnostic quality. Results There was excellent agreement among trained observers when scoring LGE-MRI scans, with inter-rater reliability scores ranging from 0.65 to 0.76 for each category. When the quality scores were converted to a binary diagnostic/non-diagnostic, the CNN achieved a sensitivity of \(0.80 \pm 0.06\) and a specificity of \(0.56 \pm 0.10\). Conclusion The use of a training document with reference examples helped raters achieve excellent agreement in their quality scores. The CNN gave a reasonably accurate classification of diagnostic or non-diagnostic 3D LGE-MRI images of the left atrium, despite the use of a relatively small training set.- Open Access
- 17 October 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (11)
Are drivers recurring or ephemeral? observations from serial mapping of persistent atrial fibrillation
Aims: Rotational re-entries and ectopic foci, or ‘drivers’, are proposed mechanisms for persistent atrial fibrillation (persAF), but driver-based interventions have had mixed success in clinical trials. Selective targeting of drivers with multi-month stability may improve these interventions, but no prior work has investigated whether drivers can be stable on such a long timescale. Objective: We hypothesized that drivers could recur even several months after initial observation. Methods and results: We performed serial electrophysiology studies on paced canines (n = 18, 27–35 kg) at 1−, 3−, and 6 months post-initiation of continual persAF. Using a high-density 64-electrode catheter, we captured endocardial electrograms in the left atrium (LA) and right atrium (RA) to determine the presence of drivers at each major anatomical site. We defined drivers that were repeatedly observed across consecutive studies to be recurrent. The mean probability that any driver would recur was 66% (LA: 73%, RA: 41%). We also found evidence of ‘multi-recurring’ drivers, i.e. those seen in all three studies. Multi-recurring drivers constituted 53% of initially observed drivers with at least one found in 92% of animals, and we found more multi-recurring drivers per animal than predicted by random chance (2.6 ± 1.5 vs. 1.2 ± 1.1, P < 0.001). Driver sites showed more enhancement than non-drivers during late gadolinium enhancement-magnetic resonance imaging (P = 0.04), but we observed no relationship between enhancement and driver recurrence type. Conclusion: We observed recurring drivers over a 6-month period at fixed locations, confirming our hypothesis. We also found drivers to be associated with fibrosis, implying a structural basis.
- 17 October 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (11)
Open AccessAre drivers recurring or ephemeral? observations from serial mapping of persistent atrial fibrillation
Aims: Rotational re-entries and ectopic foci, or ‘drivers’, are proposed mechanisms for persistent atrial fibrillation (persAF), but driver-based interventions have had mixed success in clinical trials. Selective targeting of drivers with multi-month stability may improve these interventions, but no prior work has investigated whether drivers can be stable on such a long timescale. Objective: We hypothesized that drivers could recur even several months after initial observation. Methods and results: We performed serial electrophysiology studies on paced canines (n = 18, 27–35 kg) at 1−, 3−, and 6 months post-initiation of continual persAF. Using a high-density 64-electrode catheter, we captured endocardial electrograms in the left atrium (LA) and right atrium (RA) to determine the presence of drivers at each major anatomical site. We defined drivers that were repeatedly observed across consecutive studies to be recurrent. The mean probability that any driver would recur was 66% (LA: 73%, RA: 41%). We also found evidence of ‘multi-recurring’ drivers, i.e. those seen in all three studies. Multi-recurring drivers constituted 53% of initially observed drivers with at least one found in 92% of animals, and we found more multi-recurring drivers per animal than predicted by random chance (2.6 ± 1.5 vs. 1.2 ± 1.1, P < 0.001). Driver sites showed more enhancement than non-drivers during late gadolinium enhancement-magnetic resonance imaging (P = 0.04), but we observed no relationship between enhancement and driver recurrence type. Conclusion: We observed recurring drivers over a 6-month period at fixed locations, confirming our hypothesis. We also found drivers to be associated with fibrosis, implying a structural basis.
- Open Access
Statistical Shape Modeling of Biventricular Anatomy with Shared Boundaries
Statistical shape modeling (SSM) is a valuable and powerful tool to generate a detailed representation of complex anatomy that enables quantitative analysis and the comparison of shapes and their variations. SSM applies mathematics, statistics, and computing to parse the shape into a quantitative representation (such as correspondence points or landmarks) that will help answer various questions about the anatomical variations across the population. Complex anatomical structures have many diverse parts with varying interactions or intricate architecture. For example, the heart is four-chambered anatomy with several shared boundaries between chambers. Coordinated and efficient contraction of the chambers of the heart is necessary to adequately perfuse end organs throughout the body. Subtle shape changes within these shared boundaries of the heart can indicate potential pathological changes that lead to uncoordinated contraction and poor end-organ perfusion. Early detection and robust quantification could provide insight into ideal treatment techniques and intervention timing. However, existing SSM approaches fall short of explicitly modeling the statistics of shared boundaries. This paper presents a general and flexible data-driven approach for building statistical shape models of multi-organ anatomies with shared boundaries that capture morphological and alignment changes of individual anatomies and their shared boundary surfaces throughout the population. We demonstrate the effectiveness of the proposed methods using a biventricular heart dataset by developing shape models that consistently parameterize the cardiac biventricular structure and the interventricular septum (shared boundary surface) across the population data.
Open AccessStatistical Shape Modeling of Biventricular Anatomy with Shared Boundaries
Statistical shape modeling (SSM) is a valuable and powerful tool to generate a detailed representation of complex anatomy that enables quantitative analysis and the comparison of shapes and their variations. SSM applies mathematics, statistics, and computing to parse the shape into a quantitative representation (such as correspondence points or landmarks) that will help answer various questions about the anatomical variations across the population. Complex anatomical structures have many diverse parts with varying interactions or intricate architecture. For example, the heart is four-chambered anatomy with several shared boundaries between chambers. Coordinated and efficient contraction of the chambers of the heart is necessary to adequately perfuse end organs throughout the body. Subtle shape changes within these shared boundaries of the heart can indicate potential pathological changes that lead to uncoordinated contraction and poor end-organ perfusion. Early detection and robust quantification could provide insight into ideal treatment techniques and intervention timing. However, existing SSM approaches fall short of explicitly modeling the statistics of shared boundaries. This paper presents a general and flexible data-driven approach for building statistical shape models of multi-organ anatomies with shared boundaries that capture morphological and alignment changes of individual anatomies and their shared boundary surfaces throughout the population. We demonstrate the effectiveness of the proposed methods using a biventricular heart dataset by developing shape models that consistently parameterize the cardiac biventricular structure and the interventricular septum (shared boundary surface) across the population data.
- 1 January 2022
- Published by Springer Nature
- Vol. 13593, 302-316
Statistical Shape Modeling of Biventricular Anatomy with Shared Boundaries
Statistical shape modeling (SSM) is a valuable and powerful tool to generate a detailed representation of complex anatomy that enables quantitative analysis and the comparison of shapes and their variations. SSM applies mathematics, statistics, and computing to parse the shape into a quantitative representation (such as correspondence points or landmarks) that will help answer various questions about the anatomical variations across the population. Complex anatomical structures have many diverse parts with varying interactions or intricate architecture. For example, the heart is a four-chambered anatomy with several shared boundaries between chambers. Coordinated and efficient contraction of the chambers of the heart is necessary to adequately perfuse end organs throughout the body. Subtle shape changes within these shared boundaries of the heart can indicate potential pathological changes that lead to uncoordinated contraction and poor end-organ perfusion. Early detection and robust quantification could provide insight into ideal treatment techniques and intervention timing. However, existing SSM approaches fall short of explicitly modeling the statistics of shared boundaries. In this paper, we present a general and flexible data-driven approach for building statistical shape models of multi-organ anatomies with shared boundaries that captures morphological and alignment changes of individual anatomies and their shared boundary surfaces throughout the population. We demonstrate the effectiveness of the proposed methods using a biventricular heart dataset by developing shape models that consistently parameterize the cardiac biventricular structure and the interventricular septum (shared boundary surface) across the population data. Keywords Statistical shape modeling Biventricular Cardiac MRI Particle-based shape modeling Interventricular septum
- 1 January 2022
- Published by Springer Nature
- Vol. 13593, 302-316
Statistical Shape Modeling of Biventricular Anatomy with Shared Boundaries
Statistical shape modeling (SSM) is a valuable and powerful tool to generate a detailed representation of complex anatomy that enables quantitative analysis and the comparison of shapes and their variations. SSM applies mathematics, statistics, and computing to parse the shape into a quantitative representation (such as correspondence points or landmarks) that will help answer various questions about the anatomical variations across the population. Complex anatomical structures have many diverse parts with varying interactions or intricate architecture. For example, the heart is a four-chambered anatomy with several shared boundaries between chambers. Coordinated and efficient contraction of the chambers of the heart is necessary to adequately perfuse end organs throughout the body. Subtle shape changes within these shared boundaries of the heart can indicate potential pathological changes that lead to uncoordinated contraction and poor end-organ perfusion. Early detection and robust quantification could provide insight into ideal treatment techniques and intervention timing. However, existing SSM approaches fall short of explicitly modeling the statistics of shared boundaries. In this paper, we present a general and flexible data-driven approach for building statistical shape models of multi-organ anatomies with shared boundaries that captures morphological and alignment changes of individual anatomies and their shared boundary surfaces throughout the population. We demonstrate the effectiveness of the proposed methods using a biventricular heart dataset by developing shape models that consistently parameterize the cardiac biventricular structure and the interventricular septum (shared boundary surface) across the population data. Keywords Statistical shape modeling Biventricular Cardiac MRI Particle-based shape modeling Interventricular septum